1、COPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LTD SERVICE MANUAL General Power requirementsAC 200-240V, 50/60 Hz Power consumptionOperation mode : 23W Standby mode : 6.7W Dimensions (approx.)430 X 97.5 X 293 mm (w/h/d) Mass (approx.8 kg Operating temperaturC to 35 C (41 F to 95 F) Operating humidity5 % to
2、 90 % Timer24 hours display tape Program capacity 1 month 7 program RF ModulatorUHF 22-68 (Adjustable) System Laser Semiconductor laser, wavelength 650 nm Video Head systemDouble azimuth 4 heads, helical scanning. Signal systemPAL Frequency responseDVD (PCM 96 kHz): 8 Hz to 44 kHz DVD (PCM 48 kHz):
3、8 Hz to 22 kHz CD: 8 Hz to 20 kHz Signal-to-noise ratioMore than 100dB (ANALOG OUT connectors only) Harmonic distortionLess than 0.008% Dynamic rangeMore than 100 dB (DVD) More than 95 dB (CD) Inputs (VCR) Audi6.0dBm, more than 10 kohms (SCART) -6.0dBm, more than 47 kohms (RCA) Video1.0 Vp-p, 75 ohm
4、s, unbalanced (SCART/RCA) Outputs (DVD) S-VIDEO OUT(Y) 1.0 Vp-p 75 ohms, negative sync., Mini Din 4-pin x 1 (C) 0.3 Vp-p 75 ohms COMPONENT VIDEO OUT(Y) 1.0 V (p-p), 75 , negative sync, RCA jack x 1 (Pb)/(Pr) 0.7 V (p-p), 75 , RCA jack x 2 Audio output (digital audio)0 5 V (p-p), 75 , RCA jack x 1 Au
5、dio output (optical audio)5 V (p-p), 75 , Optical connector x 1 Audio output (analog audio)2 0 Vrms (1 kHz, 0 dB), 330 , RCA jack (L, R) x 2/SCART(TO TV) Outputs (VCR) Audi6 0dBm, less than 1 kohms (SCART) Video1 0Vp-p, 75 ohms, unbalanced (SCART) Design and specifications are subject to change with
6、out notice. )4 o- o- e5 Manufactured under license from Dolby Laboratories. “ Dolby” and double-D symbol are trademarks of Dolby Laboratories. Confidential Unpublished Works. 1992-1997 Dolby Laboratories, Inc. All rights reserved. Manufactured under license from Digital Theater Systems, Inc. US Pat.
7、 No. 5,451,942 and other world-wide patents issued and pending. “ DTS” and “ DTS Digital Out” are trademarks of Digital Theater Systems, Inc. Copyright 1996 Digital Theater Systems, Inc. All rights reserved. No.82984 2003/06 HR-XV2EX, HR-XV2EY, HR-XV2EL, HR-XV11EX HR-XV2EX,HR-XV2EY,HR-XV2EL,HR-XV11E
8、X D2VP11 DVD PLAYER /VIDEO CASSETTE RECORDER SPECIFICATIONS (The specifications shown pertain specifically to the model HR-XV2E.) PAL R VV W DVD M NUME OR S B IEA G E SEA CH S VD O u + VV VC V VCR R + V VCR V 2 4 79 ND M SY K A RadioFans.CN 收音机爱 好者资料库 CONTENTS SECTION 1 . . . . SUMMARY SECTION 3 . .
9、 . . ELECTRICAL SECTION 4 . . . . MECHANISM OF VCR PART SECTION 5 . . . . MECHANISM OF DVD PART SECTION 6 . . . . REPLACEMENT PARTS LIST RadioFans.CN 收音机爱 好者资料库 SECTION 1 SUMMARY CONTENTS Important Safety Precautions SPECIFICATIONS . 1-5 RadioFans.CN 收音机爱 好者资料库 Important Safety Precautions Prior to
10、shipment from the factory, JVC products are strictly inspected to conform with the recognized product safety and electrical codes of the countries in which they are to be sold. However, in order to maintain such compliance, it is equally important to implement the following precautions when a set is
11、 being serviced. Fig.1 1.Locations requiring special caution are denoted by labels and inscriptions on the cabinet, chassis and certain parts of the product. When performing service, be sure to read and com- ply with these and other cautionary notices appearing in the operation and service manuals.
12、2.Parts identified by the symbol and shaded ( ) parts are critical for safety. Replace only with specified part numbers. Note: Parts in this category also include those specified to com- ply with X-ray emission standards for products using cathode ray tubes and those specified for compliance with va
13、rious regulations regarding spurious radiation emission. 3.Fuse replacement caution notice. Caution for continued protection against fire hazard. Replace only with same type and rated fuse(s) as specified. 4.Use specified internal wiring. Note especially: 1) Wires covered with PVC tubing 2) Double i
14、nsulated wires 3) High voltage leads 5.Use specified insulating materials for hazardous live parts. Note especially: 1) Insulation Tape3) Spacers5) Barrier 2) PVC tubing4) Insulation sheets for transistors 6.When replacing AC primary side components (transformers, power cords, noise blocking capacit
15、ors, etc.) wrap ends of wires securely about the terminals before soldering. Power cord Fig.2 10. Also check areas surrounding repaired locations. 11. Products using cathode ray tubes (CRTs) In regard to such products, the cathode ray tubes themselves, the high voltage circuits, and related circuits
16、 are specified for compliance with recognized codes pertaining to X-ray emission. Consequently, when servicing these products, replace the cath- ode ray tubes and other parts with only the specified parts. Under no circumstances attempt to modify these circuits. Unauthorized modification can increas
17、e the high voltage value and cause X-ray emission from the cathode ray tube. 12. Crimp type wire connector In such cases as when replacing the power transformer in sets where the connections between the power cord and power transformer primary lead wires are performed using crimp type connectors, if
18、 replacing the connectors is unavoidable, in or- der to prevent safety hazards, perform carefully and precisely according to the following steps. 1) Connector part number : E03830-001 2) Required tool : Connector crimping tool of the proper type which will not damage insulated parts. 3) Replacement
19、procedure (1) Remove the old connector by cutting the wires at a point close to the connector. Important : Do not reuse a connector (discard it). Fig.7 cut close to connector Fig.3 (2) Strip about 15 mm of the insulation from the ends of the wires. If the wires are stranded, twist the strands to avo
20、id frayed conductors. 15 mm Fig.4 (3) Align the lengths of the wires to be connected. Insert the wires fully into the connector. Connector Metal sleeve Fig.5 (4) As shown in Fig.6, use the crimping tool to crimp the metal sleeve at the center position. Be sure to crimp fully to the complete closure
21、of the tool. 1 vPrecautions during Servicing 7.Observe that wires do not contact heat producing parts (heatsinks, oxide metal film resistors, fusible resistors, etc.) 8.Check that replaced wires do not contact sharp edged or pointed parts. 9.When a power cord has been replaced, check that 10-15 kg o
22、f force in any direction will not loosen it. 1.25 2.0 5.5 Crimping tool Fig.6 (5) Check the four points noted in Fig.7. Not easily pulled free Crimped at approx. center of metal sleeve Conductors extended Wire insulation recessed more than 4 mm S40888-01 vSafety Check after Servicing Examine the are
23、a surrounding the repaired location for damage or deterioration. Observe that screws, parts and wires have been returned to original positions, Afterwards, perform the following tests and confirm the specified values in order to verify compli- ance with safety standards. 1.Insulation resistance test
24、 Confirm the specified insulation resistance or greater between power cord plug prongs and externally exposed parts of the set (RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, earphone jacks, etc.). See table 1 below. 2.Dielectric strength test Confirm