1、SERVICE MANUAL COPYRIGHT 2004 VICTOR COMPANY OF JAPAN, LIMITED No.YD008 2004/3 DVD PLAYER preset to Channel 3 when shipped) 75 , unbalanced TIMER Clock referenceQuartz Program capacity1-year programmable timer/8 programs Memory backup timeApprox. 5 seconds ACCESSORIES Provided accessories RF cable,
2、Audio/Video cable, Infrared remote control unit, AA battery 2 RF cable, Infrared remote control unit, AA battery 2 RadioFans.CN 收音机爱 好者资料库 (No.YD008)1-3 SECTION 1 PRECAUTION 1.1SAFTY PRECAUTIONS Prior to shipment from the factory, JVC products are strictly in- spected to conform with the recognized
3、product safety and elec- trical codes of the countries in which they are to be sold.However,in order to maintain such compliance, it is equally important to implement the following precautions when a set is being serviced. 1.1.1Precautions during Servicing (1) Locations requiring special caution are
4、 denoted by labels and inscriptions on the cabinet, chassis and certain parts of the product.When performing service, be sure to read and comply with these and other cautionary notices appearing in the operation and service manuals. (2) Parts identified by the symbol and shaded ( ) parts are critica
5、l for safety. Replace only with specified part numbers. NOTE : Parts in this category also include those specified to comply with X-ray emission standards for products using cathode ray tubes and those specified for compliance with various regulations regarding spu- rious radiation emission. (3) Fus
6、e replacement caution notice. Caution for continued protection against fire hazard. Replace only with same type and rated fuse(s) as speci- fied. (4) Use specified internal wiring. Note especially: Wires covered with PVC tubing Double insulated wires High voltage leads (5) Use specified insulating m
7、aterials for hazardous live parts. Note especially: Insulation Tape PVC tubing Spacers Insulation sheets for transistors Barrier (6) When replacing AC primary side components (transformers, power cords, noise blocking capacitors, etc.) wrap ends of wires securely about the terminals before soldering
8、. Fig.1-1-1 (7) Observe that wires do not contact heat producing parts (heatsinks, oxide metal film resistors, fusible resistors, etc.) (8) Check that replaced wires do not contact sharp edged or pointed parts. (9) When a power cord has been replaced, check that 10-15 kg of force in any direction wi
9、ll not loosen it. Fig.1-1-2 (10) Also check areas surrounding repaired locations. (11) Products using cathode ray tubes (CRTs)In regard to such products, the cathode ray tubes themselves, the high volt- age circuits, and related circuits are specified for compli- ance with recognized codes pertainin
10、g to X-ray emission. Consequently, when servicing these products, replace the cathode ray tubes and other parts with only the specified parts. Under no circumstances attempt to modify these cir- cuits.Unauthorized modification can increase the high volt- age value and cause X-ray emission from the c
11、athode ray tube. (12) Crimp type wire connectorIn such cases as when replacing the power transformer in sets where the connections be- tween the power cord and power trans former primary lead wires are performed using crimp type connectors, if replac- ing the connectors is unavoidable, in order to p
12、revent safe- ty hazards, perform carefully and precisely according to the following steps. Connector part number :E03830-001 Required tool : Connector crimping tool of the proper type which will not damage insulated parts. Replacement procedure a) Remove the old connector by cutting the wires at a p
13、oint close to the connector.Important : Do not re- use a connector (discard it). Fig.1-1-3 b) Strip about 15 mm of the insulation from the ends of the wires. If the wires are stranded, twist the strands to avoid frayed conductors. Fig.1-1-4 c) Align the lengths of the wires to be connected. In- sert
14、 the wires fully into the connector. Fig.1-1-5 d) As shown in Fig.1-1-6, use the crimping tool to crimp the metal sleeve at the center position. Be sure to crimp fully to the complete closure of the tool. Fig.1-1-6 e) Check the four points noted in Fig.1-1-7. Fig.1-1-7 Power cord cut close to connec
15、tor 15 mm Connector Metal sleeve 1.25 2.0 5.5 Crimping tool Not easily pulled free Crimped at approx. center of metal sleeve Conductors extended Wire insulation recessed more than 4 mm RadioFans.CN 收音机爱 好者资料库 1-4 (No.YD008) 1.1.2Safety Check after Servicing Examine the area surrounding the repaired
16、location for damage or deterioration. Observe that screws, parts and wires have been returned to original positions, Afterwards, perform the following tests and confirm the specified values in order to verify compli- ance with safety standards. (1) Insulation resistance test Confirm the specified in
17、sulation resistance or greater be- tween power cord plug prongs and externally exposed parts of the set (RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, ear- phone jacks, etc.).See table 1 below. (2) Dielectric strength test Confirm specified dielectric
18、 strength or greater between power cord plug prongs and exposed accessible parts of the set (RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, earphone jacks, etc.). See Fig.1-1-11 below. (3) Clearance distance When replacing primary circuit components, c
19、onfirm spec- ified clearance distance (d), (d) between soldered termi- nals, and between terminals and surrounding metallic parts. See Fig.1-1-11 below. Fig.1-1-8 (4) Leakage current test Confirm specified or lower leakage current between earth ground/power cord plug prongs and externally exposed ac
20、- cessible parts (RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, ear- phone jacks, etc.). Measuring Method : (Power ON)Insert load Z between earth ground/power cord plug prongs and externally ex- posed accessible parts. Use an AC voltmeter to measure a
21、cross both terminals of load Z. See Fig.1-1-9 and follow- ing Fig.1-1-12. Fig.1-1-9 (5) Grounding (Class 1 model only) Confirm specified or lower grounding impedance between earth pin in AC inlet and externally exposed accessible parts (Video in, Video out, Audio in, Audio out or Fixing screw etc.).
22、Measuring Method: Connect milli ohm meter between earth pin in AC inlet and exposed accessible parts. See Fig.1-1-10 and grounding specifications. Fig.1-1-10 Fig.1-1-11 Fig.1-1-12 NOTE : These tables are unofficial and for reference only. Be sure to confirm the precise values for your particular cou
23、ntry and locality. Chassis Power cord primary wire d d ab c V A Externally exposed accessible part Z Exposed accessible part Grounding Specifications AC inlet Region USA 1) The idler gear is not meshed with the take-up reel gear because the mechanism mal-functions for some reason. 2) The idler gear
24、is meshed with the take-up reel gear, but incapable of winding due to too large mechanical load (abnormal tension); 3) The reel is rotating normally but an FG pulse is not generated due to the take-up reel sensor failure. 2.The supply reel pulse is not generated in the REV transport modes (REV SEARC