LG-BD370-br-sm 电路图 维修手册.pdf
《LG-BD370-br-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《LG-BD370-br-sm 电路图 维修手册.pdf(107页珍藏版)》请在收音机爱好者资料库上搜索。
1、P/NO : AFN70285080 FEB, 2009 BLU-RAY DISC PLAYER SERVICE MANUAL MODEL : BD370 CAUTION BEFORE SERVICING THE UNIT, READ THE “SAFETY PRECAUTIONS” IN THIS MANUAL. Website Internal Use Only MODEL : BD370SERVICE MANUAL Av. Sor Juana lns de la Cruz No 555 Col. San Lorenzo Tlalnepantla, Estado de Mxico CP 5
2、4033 Tel. 321 19 00 Fax. 5 657549 Lada sin costo 01 800 50 481 00 RadioFans.CN 收音机爱 好者资料库 1-1Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only CONTENTS SECTION 1 .SUMMARY SECTION 2 .CABINET & MAIN CHASSIS SECTION 3 .ELECTRICAL SECTIO
3、N 4 .HL-04P LOADER PART SECTION 5 .REPLACEMENT PARTS LIST RadioFans.CN 收音机爱 好者资料库 1-2Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only SECTION 1 SUMMARY CONTENTS PRODUCT SAFETY SERVICING GUIDELINES FOR BLU-RAY DISC PLAYER PRODUCTS. 1
4、-3 SERVICING PRECAUTIONS .1-4 General ServicinG PrecautionS inSulation checkinG Prodedure electroStatically SenSitive (eS) deviceS SOFTWARE UPGRADE . 1-5 SPECIFICATIONS .1-6 RadioFans.CN 收音机爱 好者资料库 1-3Copyright 2009 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE
5、Internal Use Only PRODUCT SAFETY SERVICING GUIDELINES FOR BLU-RAY DISC PLAYER PRODUCTS IMPORTANT SAFETY NOTICE this manual was prepared for use only by properly trained audio-video service technicians. When servicing this product, under no circumstances should the original design be modified or alte
6、red without permission from lG corporation. all components should be replaced only with types identical to those in the original circuit and their physical location, wiring and lead dress must conform to original layout upon completion of repairs. Special components are also used to prevent x-radiat
7、ion, shock and fire hazard. these components are indicated by the letter “x” included in their component des- ignators and are required to maintain safe performance. no deviations are allowed without prior approval by lG corporation. circuit diagrams may occasionally differ from the actual circuit u
8、sed. this way, implementation of the latest safety and performance improvement changes into the set is not delayed until the new service literature is printed. CAUTION : do not attempt to modify this product in any way. never perform cus- tomized installations without manufacturers approval. unautho
9、rized modifications will not only void the warranty, but may lead to property damage or user injury. Service work should be performed only after you are thoroughly familiar with these safety checks and servicing guidelines. GRAPHIC SYMBOLS the exclamation point within an equilateral triangle is inte
10、nded to alert the service personnel to important safety information in the service literature. the lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the service personnel to the presence of noninsulated “dangerous voltage” that may be of sufficient magnitude t
11、o constitute a risk of electric shock. the pictorial representation of a fuse and its rating within an equi- lateral triangle is intended to convey to the service personnel the following fuse replacement caution notice: CAUTION : For continued Protection aGainSt riSk oF Fire, rePlace all FuSeS With
12、the SaMe tyPe and ratinG aS Marked near each FuSe. SERVICE INFORMATION While servicing, use an isolation transformer for protection from ac line shock. after the original service problem has been corrected, make a check of the following: FIRE AND SHOCK HAZARD 1. Be sure that all components are posit
13、ioned to avoid a possibility of adjacent component shorts. this is especially important on items trans-ported to and from the repair shop. 2. verify that all protective devices such as insulators, barriers, covers, shields, strain reliefs, power supply cords, and other hardware have been reinstalled
14、 per the original design. Be sure that the safety purpose of the polarized line plug has not been defeated. 3. Soldering must be inspected to discover possible cold solder joints, solder splashes, or sharp solder points. Be certain to remove all loose foreign par- ticles. 4. check for physical evide
15、nce of damage or deterioration to parts and compo- nents, for frayed leads or damaged insulation (including the ac cord), and replace if necessary. 5. no lead or component should touch a high current device or a resistor rated at 1 watt or more. lead tension around protruding metal surfaces must be
16、avoided. 6. after reassembly of the set, always perform an ac leakage test on all exposed metallic parts of the cabinet (the channel selector knobs, antenna terminals, handle and screws) to be sure that set is safe to operate without danger of electrical shock. do not uSe a line iSolation tranSForMe
17、r durinG thiS teSt. use an ac voltmeter having 5000 ohms per volt or more sensitivity in the following manner: connect a 1500 ohm, 10 watt resistor, paralleled by a .15 mfd 150v ac type capacitor between a known good earth ground water pipe, conduit, etc.) and the exposed metallic parts, one at a ti
18、me. Measure the ac volt- age across the combination of 1500 ohm resistor and .15 mfd capacitor. reverse the ac plug by using a non-polarized adaptor and repeat ac voltage measure- ments for each exposed metallic part. voltage measured must not exceed 0.75 volts rMS. this corresponds to 0.5 milliamp
19、ac. any value exceeding this limit constitutes a potential shock hazard and must be corrected immediately. TIPS ON PROPER INSTALLATION 1. never install any receiver in a closed-in recess, cubbyhole, or closely fitting shelf space over, or close to, a heat duct, or in the path of heated air flow. 2.
20、avoid conditions of high humidity such as: outdoor patio installations where dew is a factor, near steam radiators where steam leakage is a factor, etc. 3. avoid placement where draperies may obstruct venting. the customer should also avoid the use of decorative scarves or other coverings that might
21、 obstruct ventilation. 4. Wall- and shelf-mounted installations using a commercial mounting kit must follow the factory-approved mounting instructions. a product mounted to a shelf or platform must retain its original feet (or the equivalent thickness in spacers) to provide adequate air flow across
22、the bottom. Bolts or screws used for fasteners must not touch any parts or wiring. Perform leakage tests on customized instal- lations. 5. caution customers against mounting a product on a sloping shelf or in a tilted position, unless the receiver is properly secured. 6. a product on a roll-about ca
23、rt should be stable in its mounting to the cart. caution the customer on the hazards of trying to roll a cart with small casters across thresholds or deep pile carpets. 7. caution customers against using extension cords. explain that a forest of exten- sions, sprouting from a single outlet, can lead