LG-LRM519-mr-sm 电路图 维修手册.pdf
《LG-LRM519-mr-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《LG-LRM519-mr-sm 电路图 维修手册.pdf(192页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL LG LRM-519 DIGITAL MEDIARECORDER SERVICE MANUAL MODEL : LRM-519(RV7922M) CAUTION BEFORE SERVICING THE UNIT, READ THE “SAFETYPRECAUTIONS” IN THIS MANUAL. MODEL : LRM-519(RV7922M)SERVICE MANUAL P/NO : 3829RVN004LAUGUST, 2005 RadioFans.CN 收音机爱 好者资料库 1-1 SECTION 1 SUMMARY CONTENTS PRODUCT
2、 SAFETY SERVICING GUIDELINES FOR VIDEO PRODUCTS.1-2 SERVICING PRECAUTIONS.1-3 INTRODUCTION .1-4 SPECIFICATIONS.1-5 SYSTEM S/W UPGRADE.1-7 TEST S/W .1-8 RadioFans.CN 收音机爱 好者资料库 1-2 IMPORTANT SAFETY NOTICE This manual was prepared for use only by properly trained audio-video service technicians. When
3、servicing this product, under no circumstances should the original design be modified or altered without permission from Zenith Electronics Corporation. All components should be replaced only with types identical to those in the original circuit and their physical location, wiring and lead dress mus
4、t conform to original layout upon completion of repairs. Special components are also used to prevent x-radiation, shock and fire haz- ard. These components are indicated by the letter “x” included in their compo- nent designators and are required to maintain safe performance. No deviations are allow
5、ed without prior approval by Zenith Electronics Corporation. Circuit diagrams may occasionally differ from the actual circuit used. This way, implementation of the latest safety and performance improvement changes into the set is not delayed until the new service literature is printed. CAUTION: Do n
6、ot attempt to modify this product in any way. Never perform customized installations without manufacturers approval. Unauthorized modi- fications will not only void the warranty, but may lead to property damage or user injury. Service work should be performed only after you are thoroughly familiar w
7、ith these safety checks and servicing guidelines. GRAPHIC SYMBOLS The exclamation point within an equilateral triangle is intended to alert the service personnel to important safety information in the service literature. The lightning flash with arrowhead symbol within an equilateral tri- angle is i
8、ntended to alert the service personnel to the presence of noninsulated “dangerous voltage” that may be of sufficient magni- tude to constitute a risk of electric shock. The pictorial representation of a fuse and its rating within an equi- lateral triangle is intended to convey to the service personn
9、el the following fuse replacement caution notice: CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ALL FUSES WITH THE SAME TYPE AND RATING AS MARKED NEAR EACH FUSE. SERVICE INFORMATION While servicing, use an isolation transformer for protection from AC line shock. After the original
10、service problem has been corrected, make a check of the fol- lowing: FIRE AND SHOCK HAZARD 1. Be sure that all components are positioned to avoid a possibility of adjacent component shorts. This is especially important on items trans-ported to and from the repair shop. 2. Verify that all protective
11、devices such as insulators, barriers, covers, shields, strain reliefs, power supply cords, and other hardware have been reinstalled per the original design. Be sure that the safety purpose of the polarized line plug has not been defeated. 3. Soldering must be inspected to discover possible cold sold
12、er joints, solder splashes, or sharp solder points. Be certain to remove all loose foreign par- ticles. 4. Check for physical evidence of damage or deterioration to parts and compo- nents, for frayed leads or damaged insulation (including the AC cord), and replace if necessary. 5. No lead or compone
13、nt should touch a high current device or a resistor rated at 1 watt or more. Lead tension around protruding metal surfaces must be avoided. 6. After reassembly of the set, always perform an AC leakage test on all exposed metallic parts of the cabinet (the channel selector knobs, antenna terminals, h
14、andle and screws) to be sure that set is safe to operate without danger of electrical shock. DO NOT USE A LINE ISOLATION TRANS- FORMER DURING THIS TEST. Use an AC voltmeter having 5000 ohms per volt or more sensitivity in the following manner: Connect a 1500 ohm, 10 watt resistor, paralleled by a .1
15、5 mfd 150V AC type capacitor between a known good earth ground water pipe, conduit, etc.) and the exposed metal- lic parts, one at a time. Measure the AC voltage across the combination of 1500 ohm resistor and .15 mfd capacitor. Reverse the AC plug by using a non-polarized adaptor and repeat AC volt
16、age measurements for each exposed metallic part. Voltage measured must not exceed 0.75 volts RMS. This corresponds to 0.5 milliamp AC. Any value exceeding this limit consti- tutes a potential shock hazard and must be corrected immediately. TIPS ON PROPER INSTALLATION 1. Never install any receiver in
17、 a closed-in recess, cubbyhole, or closely fitting shelf space over, or close to, a heat duct, or in the path of heated air flow. 2. Avoid conditions of high humidity such as: outdoor patio installations where dew is a factor, near steam radiators where steam leakage is a factor, etc. 3. Avoid place
18、ment where draperies may obstruct venting. The customer should also avoid the use of decorative scarves or other coverings that might obstruct ventilation. 4. Wall- and shelf-mounted installations using a commercial mounting kit must follow the factory-approved mounting instructions. A product mount
19、ed to a shelf or platform must retain its original feet (or the equivalent thickness in spacers) to provide adequate air flow across the bottom. Bolts or screws used for fasteners must not touch any parts or wiring. Perform leakage tests on customized installations. 5. Caution customers against moun
20、ting a product on a sloping shelf or in a tilt- ed position, unless the receiver is properly secured. 6. A product on a roll-about cart should be stable in its mounting to the cart. Caution the customer on the hazards of trying to roll a cart with small cast- ers across thresholds or deep pile carpe
21、ts. 7. Caution customers against using extension cords. Explain that a forest of extensions, sprouting from a single outlet, can lead to disastrous conse- quences to home and family. A.C. Voltmeter 1500 OHM 10 WATT Place this probe on each exposed metal part. Good Earth Ground such as the Water Pipe
22、, Conduit, etc. 0.15uF PRODUCT SAFETY SERVICING GUIDELINES FOR VIDEO PRODUCTS RadioFans.CN 收音机爱 好者资料库 1-3 SERVICING PRECAUTIONS CAUTION: Before servicing the HD/SD PERSONAL VIDEO RECORDER & RECEIVER WITH GEMSTAR covered by this service data and its supplements and addends, read and follow the SAFETY
23、 PRECAUTIONS. NOTE: if unforeseen circumstances create conflict between the following servic- ing precautions and any of the safety precautions in this pub- lications, always follow the safety precautions. Remember Safety First: General Servicing Precautions 1. Always unplug the HD/SD PERSONALVIDEO
24、RECORDER & RECEIVER WITH GEMSTAR AC power cord from the AC power source before: (1)Removing or reinstalling any component, circuit board, module, or any other assembly. (2)Disconnecting or reconnecting any internal electrical plug or other electrical connection. (3)Connecting a test substitute in pa