1、T echnical Manual SURROUND SOUND PROCESSOR RSP-1069 Table of Contents Specification.1 Parts List.213 Upgrade Procedure.1420 Wiring.21 PCB Assembly.2227 Schematic Diagram .2844 SHINSEN-BLD. 4F 10-10 SHINSEN-CHO, SHIBUYA-KU, TOKYO 150-0045, JAPAN Serial. NO. Beginning Quality Uncompromised Y-407A-0709
2、/pdf THE ROTEL CO., LTD. Specifications Audio Total Harmonic Distortion 0.008% Intermodulation Distortion (60 Hz:7 kHz) Other - Main Upgrade - yes press Enter. 4.Copy Object file(.HEX) and INI file (main_rsp1069.ini) file, and save it in temporary same folder. 5.Execute nec_flash_upgrade.exe from Pr
3、ogram list. 6.Load INI file by pushing Load INI button. load main_rsp1069.ini for RSP1069 main micom. 7.Load HEX file by pushing Load HEX button. load rsp1069vxxx_xxxxxx.hex for RSP1069 main micom. 14 8.After pushing COM button placed at HEX button upper, and choosing COM1COM4. (connecting PCs COM1
4、COM4 and cable). 9.Push Connect button placed at programs below left side,and BaudRate placed next to COM button will be displayed if the above process is OK. 10.Click Write button placed next to Connect button . 11. 12. AC Power OFF and ON again to save. After finshing Write, then the total writing
5、 time will be displayed. 15 RSP-1069 Scalar (VIDEO) Upgrade Software Procedure 1.Execute nec flash upgrade.exe then will be created new folder as C:Program Filesnec upgrade. 2.Connect upgrade cable between RSP-1069 and PC. 3.Set upgrade enviornment on OSD Menu OSD Main Menu- VIDEO/HDMI - Video Upgra
6、de - yes press Enter. 4.Copy Object file(.HEX) and INI file (video_scaler.ini) file, and save it in temporary same folder. 5.Execute nec_flash_upgrade.exe from Program list. 6.Load INI file by pushing Load INI button. load video_scaler.ini for video scaler CPU of the RSP-1069. 7.Load HEX file by pus
7、hing Load HEX button. load scaler1058vxxx.hex for video scaler CPU of the RSP-1069. 16 8.After pushing COM button placed at HEX button upper, and choosing COM1COM4. (connecting PCs COM1 COM4 and cable). 9.Push Connect button placed at programs below left side,and BaudRate placed next to COM button w
8、ill be displayed if the above process is OK. 10.Click Write button placed next to Connect button . 11 12 AC Power OFF and ON again to save. After finshing Write, then the total writing time will be displayed. 17 RSP-1069 DSP Upgrade Manager V1.0.0 Procedure Install the “DSP Upgrade Manager_V100” pro
9、gram which is provided by ROTEL in the computer. And connect RS232 Cable with DB-9 to RJ45 terminations. 1. Click “Open File” - select Upgrade file 2. Confirm Port and Baud Rate setting. Then, click “Next” button. (ref: RSP-1069 Baud Rate is 38400) 3. Communication port initializing Wait. Then click
10、 “Next” button. 5. Click “Next” button. 11. Finish. 6. The devices current version is displayed. Click “Next” button. 8. The sector is erased. The flash is writing automatically. Wait a while. 4. Press the “Next” button for starting the procedure. 7.The sector is erasing. Wait a moment. 10. Complete
11、d all procedure. Power off and on again on main switch of rear. Click “Exit” button to finish the “Upgrade Manager” program. 9. If the writing and checksum is OK, wait a next procedure. 18 RSP-1069 will get FL full illumination from Direct and Always ON setting Press 2CH and MUTE of front panel whil