QSC-ISA500T-pwr-sb1 电路图 维修手册.pdf
《QSC-ISA500T-pwr-sb1 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《QSC-ISA500T-pwr-sb1 电路图 维修手册.pdf(4页珍藏版)》请在收音机爱好者资料库上搜索。
1、1ISA0001 Title:ISA Turn-on Hangup Bulletin #:ISA0001Issue Date: April 4, 2002 Models Affected:ISA 750, 800T, 450, the level required generally depends on the severity of the hang-up. Background: the cause and the remedy Each channel has an operational amplifier (op amp) driving its output stage. Its
2、 supply rails furnish just enough current for normal operation by themselves and use the output signal to help replenish them. When the output stage tries to put out too much current into a short circuit or abnormally low load impedance, it clips prematurely at a very low voltage; as a result, there
3、 is not enough output signal to replenish the op amp supply rails. The starved supply rails collapse, and with them, so does the op amp output. This is a normal and vital part of the amplifiers protection against short circuits. A channel hangs when the op amp rails and the bias in the output transi
4、stor circuitry do not settle to their correct values quickly enough after turn-on. The op amp output swings to one rail, causing it to collapse and in turn causing the bias to not settle correctly. As a result, there is no negative feedback to force the op amp to resolve itself to zero volts. To cor
5、rect the situation, replace the 5.6-volt zener diodes (D107, D110, D207, and D210) with 4.7-volt diodes and recalibrate the current-limit trimpots (R139, R140, R239, and R240). Temporary work-arounds Until the amplifier can be serviced, one of these actions will usually clear its hang-up and get it
6、working properly: Quickly turning it off and on (CAUTION: this will cause an audible pop in any loudspeaker connected to the amp) Unplugging and re-connecting speaker load from the channel output Instructions Tools and materials required: Soldering iron with fine tip (recommended range 25 to 60 W) R
7、osin-core solder (60/40 or 63/37 eutectic type) Long-nose pliers #1 and #2 Philips screwdrivers Small diagonal cutters RadioFans.CN 收音机爱 好者资料库 2ISA0001 Desoldering equipment or solder braid Four 4.7-volt -watt zener diodes (Microsemi DZ840731ET/R; QSC part number QD-0004.7-ZT) Test equipment require
8、d: Oscilloscope 2-ohm resistive load (rated for at least 1200 watts) Wire or other means of shorting the amplifier output Variable AC transformer (e.g., Variac, Powerstat, etc.) rated for 25A (120V) or 12A (230V). Make sure your AC supply is appropriate for the amplifier. 1 kHz audio sine wave gener
9、ator Digital multimeter AC current probe (e.g., BK Precision model CP-1) Trimpot adjustment tool (non-conductive) Note: The circuit boards in the ISA 750 and ISA 800T are double-sided, while those in the ISA 450 and 500T are single-sided. Therefore, to minimize disassembly, this bulletin recommends
10、two different procedures among these models: In the ISA 750 and ISA 800T, the zener diodes will be unsoldered and soldered from the component side. The instruc- tions for this procedure begin below. In the ISA 450 and ISA 500T, the new zener diodes will be soldered “piggyback”-style to the old ones.
11、 The instructions for this procedure begin after those for the ISA 750 and ISA 800T. 0.3 7.6 mm 0.4 10.2 mm D107 set the assembly down in the chassis with the heat sink resting on the standoffs (Figure 2). 6.Disconnect the ribbon cable from the channel 1 module. 7.Locate zener diode D107. It is near
12、 where three wires are soldered to the circuit board and secured with hot glue. If the hot glue covers the diode, use the tip of your hot soldering iron and a small screwdriver to melt and clear the glue away (Figure 3). 8.Notice the orientation of D107. Unsolder and remove it; be careful not to dam
13、age the through-plating in the holes. Install and solder a new zener diode oriented in the same direction. Do the same with zener diode D110. 9.Reattach the ribbon cable and turn the channel module assembly back over so that the channel 2 module is on top. 10. Locate zener diode D207 and notice its
14、orientation. Carefully Tools and materials required (continued): Figure 1. Prepare the leads of the new zener diodes. Figure 2. Prop the channel module assembly up on the chassis standoffs. Figure 3. You might need to clear hot glue away from diode D107. Use your hot soldering iron tip. RadioFans.CN
15、 收音机爱 好者资料库 3ISA0001 unsolder and remove it. Install and solder a new zener diode oriented in the same direction. Do the same with diode D210. 11. Check your work. Dont reattach the channel module assembly and heat sink to the chassis yet. Instead, continue with the bias and current-limit calibratio
16、n. New 4.7-volt zener Old 5.6-volt zener sno i t arb i l aCt su j dA e r u t a r epme tt ne i bmat a (*dnamedCAe l d I ) t ohnehwr ehg i h , A4 . 0%01A6 . 0,%01 . V001r o f2 . 1ybr oV032r o f5 . 0ybt ne r r ucy l p i t l um; s r e i f i l pmaV021r o fe r anwohsse r ug i F* Procedure: Installing new
17、zener diodes in an ISA 450 or ISA 500T amplifier 1.Disconnect the amplifier from AC and wait at least 10 minutes for internal voltages to bleed down. Remove the top cover. 2.Remove the four screws on the bottom of the amplifier that fasten the heat sink to the chassis. 3.Remove the three screws that