1、2005 Bose Corporation Part Number 170310 Rev. 02 Service Manual Panaray Sound System 502 Array, Bass Box and Controller 1 TABLE OF CONTENTS 1. SAFETY INFORMATION. 2 2. SPECIFICATIONS. 3 3. THEORY OF OPERATION. 6 4. EQ CURVES. 9 5. BLOCK DIAGRAM. 15 6. DISASSEMBLY/ASSEMBLY PROCEDURES. 17 7. TEST PROC
2、EDURES. 28 8. PARTS LISTS AND EXPLODED VIEWS. 34 9. SCHEMATICS AND PCB LAYOUTS. 64 CAUTION: THE PANARAY SOUND SYSTEM CONTAINS NO USER SER- VICEABLE PARTS. TO PREVENT WARRANTY INFRACTIONS, REFER SERVICING TO WARRANTY SERVICE STATIONS OR FACTORY SERVICE. PROPRIETARY INFORMATION THIS DOCUMENT CONTAINS
3、PROPRIETARY INFORMATION OF BOSE CORPORATION WHICH IS BEING FURNISHED ONLY FOR THE PURPOSE OF SERVICING THE IDENTIFIED BOSE PRODUCT BY AN AUTHORIZED BOSE SERVICE CENTER OR OWNER OF THE BOSE PRODUCT, AND SHALL NOT BE REPRODUCED OR USED FOR ANY OTHER PURPOSE. SAFETY INFORMATION 1. Parts that have speci
4、al safety characteristics are identified by the symbol on schematics or by special notes on the parts list. Use only replacement parts that have critical characteristics recommended by the manufacturer. 2. Make leakage current or resistance measurements to determine that exposed parts are acceptably
5、 insulated from the supply circuit before returning the unit to the customer. Use the following checks to perform these measurements: A. Leakage Current Hot Check-With the unit completely reassembled, plug the AC line cord directly into a 120V AC outlet.(Do not use an isolation transformer during th
6、is test.) Use a leakage current tester or a metering system that complies with American National Standards Institute (ANSI) C101.1 Leakage Current for Appliances and Underwriters Laboratories (UL) 1492 (71). With the unit AC switch first in the ON position and then in OFF position, measure from a kn
7、own earth ground (metal waterpipe, conduit,etc.) to all exposed metal parts of the unit (antennas,handle bracket, metal cabinet,screwheads,metallic overlays,control shafts,etc.), especially any exposed metal parts that offer an electrical return path to the chassis. Any current measured must not exc
8、eed 0.5 milliamp. Reverse the unit power cord plug in the outlet and repeat test. ANY MEASUREMENTS NOT WITHIN THE LIMITS SPECIFIED HEREIN INDICATE A POTENTIAL SHOCK HAZARD THAT MUST BE ELIMINATED BEFORE RETURNING THE UNIT TO THE CUSTOMER. B. Insulation Resistance Test Cold Check-(1) Unplug the power
9、 supply and connect a jumper wire between the two prongs of the plug.(2)Turn on the power switch of the unit. (3) Measure the resistance with an ohmmeter between the jumpered AC plug and each exposed metallic cabinet part on the unit. When the exposed metallic part has a return path to the chassis,
10、the reading should be between 1 and 5.2 Megohms. When there is no return path to the chassis, the reading must be infinite. If it is not within the limits specified, there is the poss- ibility of a shock hazard, and the unit must be repaired and rechecked before it is returned to the customer. 2 SPE
11、CIFICATIONS 502A SPECIFICATIONS Dimensions:23.5 H x 5.75 Wx 6.73 D (59.7x14.6x17.1 cm) Weight:15 lbs. (6.8 kg.) Transducer5-4.5 (11.4 cm) drivers Complement: Enclosure Material:High-impact polystyrene Nominal Impedance:8, 6.4 minimum Sensitivity:90 dB SPL (1W, 1m, 130 Hz-15 kHz) Maximum Acoustic112
12、dB SPL average Output:121 dB SPL peak Frequency Range:130 Hz-15 kHz Port Tuning135 Hz Frequency: Amplifier Power150-600 watts continuous into 8 (Recommended): Long-term power150 watts continuous handling: Beamwidth:120 horizontal, 70 vertical Input Connections:Parallel wired barrier strip (US/Can.)
13、Parallel wired XLR (Eur./Aus./UK/Japan) Fusing:4 ampere AGC (Buss) or 3AG (Littlefuse) 3 4 Dimensions: 31.0 H x 14.0 W x 15.5 D(78.7x 35.6x 39.4 cm) Weight: 80 lbs. (36.4 kg.) Transducer 1- 12 woofer (high power) Complement: Enclosure Material: 3/4 resin-core, vinyl wrapped Port: High-impact polysty
14、rene Nominal Impedance: 8 , 6.4 minimum Sensitivity: 90 dB SPL (1W, 1m, 55 Hz-150 Hz) Maximum Acoustic 115 dB SPL average Output: 122 dB SPL peak Frequency Range: 50 Hz-150 Hz Power Handling: 450 watts continuous Amplifier Power 450-1200 watts continuous into 8 (Recommended): Input Connections: 2 pa
15、rallel wired barrier strip (US/Can.) 2 parallel wired XLR (Eur./Aus./UK/Japan) Fusing: 7 ampere AGC (Buss) or 3AG (Littlefuse) 502C SPECIFICATIONS 502B SPECIFICATIONS SPECIFICATIONS (Continued) Dimensions:120V/Barrier 1.75 Hx19.0Wx8.75D(4.4x48.3x22.2 cm) Strip 220-240V/XLR1.75 Hx19.0Wx8.0D(4.4x48.3x
16、20.3 cm) Weight: 5.5 lbs. (2.5 kg.) Chassis material: 16 gauge steel with painted/zinc coated finish Cover plate material: Brushed aluminum,painted 5 SPECIFICATIONS (Continued) Input Connections: Balanced barrier strip (US/Can.) Balanced XLR (Eur./Aus./UK/Japan) Output Connections: Balanced barrier
17、strip (US/Can.) Balanced High frequency & Low frequency XLR (Eur./Aus./UK/Japan) Input Impedance: Balanced input,-10 dB level: 14 k Balanced input,+4 dB level: 6 k Unbalanced input (+ input used), -10 dB level: 12 k Unbalanced input (+ input used), +4 dB level: 4 k Output Impedance: 100 nominal Inpu
18、t Level: -10 dB or +4dB,selectable Output Level: 8.0 Vrms maximum into 600 Low Frequency (LF) Sum or normal Output Mode: LF Output Level: -18 dB to +3 dB,variable Crossover Frequency: 140 Hz (Bi-amp mode),Roll-off slope: -18dB/oct. THD: Midrange distortion of HF output: 0.1 % at 5 V, 600 Hz Low freq
19、uency distortion of LF output: 0.1 % at 5V, 80 Hz Output Noise: Bi-amp mode, HF outputs 90V Bi-amp mode, LF outputs 40V Passive mode, 90V Offset: All channels 15mV Power Requirements: 120 VAC,50/60 Hz, 12 watts (US/Can.) 230 VAC,50/60 Hz, 12 watts (Eur.) 100 VAC,50/60 Hz, 12 watts (Japan) 240 VAC,50
20、/60 Hz, 12 watts (Aus./UK) 6 THEORY OF OPERATION The following discussion provides an overview of 502C electrical operation. Equalization curves are referenced and are located at the end of this discussion. Additionally, the 502C block diagram and schematic should be referenced as required. 1. Diffe
21、rential Input Stage The input stage features protection against RFI (radio frequency interference), ESD (electrostatic discharge), and overvoltage. Referring to the Channel 1 circuit, R2/C1, R1/C120, R3/C2, and R9,10/C7 provide low pass filtering to reduce the possibility of RFI. Diodes D1-D4, D25,
22、and D26 provide input clamping to protect against overvoltage and ESD. Op-amp U1 amplifies the difference between the + and - input pins, and converts it to a single ended signal that drives the equalizers. Gain switch S3 selects between two gains, a high gain setting for -10dB sources and a low gai
23、n setting for +4db sources. 2. Equalizer for High Frequency Outputs Op-amps U1, U2 and U3 constitute the principal equalization for the high frequency output. Each stage makes a contribution to the total low or high frequency contouring required by the loudspeaker. Op-amp U4 (pins 12, 13 and 14) imp
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Bose-502-A service manual 电路图 维修手册 Bose 502 维修 手册
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf