1、Approved by S.NAGAO Written by WQ-19 2 817/additional rule 3 (1st Issue 2003-03-19) Date:5-Mar.-2004Model:SR5400,SR6400,SR7400 Page:1 / 1REF.NBR:MZ04-019 Circulation:Application: Subject: Int.ref: PHENOMENON In idling state, if time passes, the top cover becomes very hot. SOLUTION 1) Idling adjustme
2、nt is changed to the following contents. A. The target setting voltage changes according to ambient temperature. B. Adjustment time and Measurement Voltage after the Power ON are changed. C. Adjustment is impossible when ambient temperature is 9 degrees centigrade or less. 2) The setup of Master Vol
3、ume-Minimum, Speaker out-No load, and Top lid-OPEN does not change. 3) Alignment Point and Measurement Point do not change. 4) Ignore 2 and 3 of Idling Current Alignment on the service manual (SR5400/SR6400 is 59 page and SR7400 is 57 page). Ambient temperature and Measurement Voltage of change are
4、the following table. Ambient temperature 10 to 19 degrees centigrade Ambient temperature 20 to 30 degrees centigrade Measurement Voltage Measurement Voltage 5 min.1.2 mV +- 0.3 mV2.0 mV +- 0.3 mV 10 min.1.2 mV +- 0.3 mV2.1 mV +- 0.3 mV 20 min1.4 mV +- 0.3 mV2.5 mV +- 0.3 mV 30 min1.6 mV +- 0.3 mV2.7
5、 mV +- 0.3 mV 40 min1.7 mV +- 0.3 mV2.9 mV +- 0.3 mV 50 min1.8 mV +- 0.3 mV3.1 mV +- 0.3 mV 60 min.1.9 mV +- 0.3 mV3.2 mV +- 0.3 mV After Turning ON REMARKS -The countermeasure apply to this claim only. -With the Unit which has returned from the customer by repair, Please also readjust the following
6、 serial number. This problem apply to following week code. SR5400 / SR6400 / SR7400 apply to MZ020405xxxxxx. This improvement has been done in the production the week code MZ020406xxxxxx and after. SERVICE BULLETIN By idling, Top cover becomes very hot so that it cannot touch by hand. x for informat
7、ion customer complaint in case of service mandatory . See below Approved by S.NAGAO Written by WQ-19 2 817/additional rule 3 (1st Issue 2003-03-19) Date:15-Mar.-2004Model: SR7400 Page:1 / 1REF.NBR:MZ04-025 Circulation:Application: Subject: Int.ref: PHENOMENON 1) It occurs when Digital connection of
8、HDD recorder (by Panasonic or Toshiba product). 2) The sound output of SR7400 is muted by HDD recorder operation. SOLUTION 1) Update the CPU(IC28)s software version to V040218_2x 2) Update the DSP(IC20)s CODE ID 02 to CD02_02010116 3) Please refer to the service manual SR7400 page58 to 62, about det
9、ails of “10.SERVICE MODE” and “ 12.UPDATE FIRMWARE ”. NECESSARY PART Update of the firmware disc *SR7400CD2 REMARKS The countermeasure apply to this claim only 1) This problem apply to the following service change code. SR7400/K1G/N1B/N1S /S1G/U1B apply to MZ02xxxxxxxxxx This improvement has been do
10、ne in the production the service change code MZ03. 2) The model SR7400/L1G has improved from the top of mass production. SERVICE BULLETIN Cant decode input signal by the operation of other company HDD RECORDER.x for information customer complaint in case of service mandatory . See Below File name of
11、 SR7400_Soft.zip for CPU File name of DSPROM_04_02_18.zip for DSP Approved by S.NAGAO Written by WQ-19 2 817/additional rule 3 (1st Issue 2003-03-19) Date:5-Mar.-2004Model:SR5400,SR6400,SR7400 Page:1 / 1REF.NBR:MZ04-019 Circulation:Application: Subject: Int.ref: PHENOMENON In idling state, if time p
12、asses, the top cover becomes very hot. SOLUTION 1) Idling adjustment is changed to the following contents. A. The target setting voltage changes according to ambient temperature. B. Adjustment time and Measurement Voltage after the Power ON are changed. C. Adjustment is impossible when ambient tempe
13、rature is 9 degrees centigrade or less. 2) The setup of Master Volume-Minimum, Speaker out-No load, and Top lid-OPEN does not change. 3) Alignment Point and Measurement Point do not change. 4) Ignore 2 and 3 of Idling Current Alignment on the service manual (SR5400/SR6400 is 59 page and SR7400 is 57
14、 page). Ambient temperature and Measurement Voltage of change are the following table. Ambient temperature 10 to 19 degrees centigrade Ambient temperature 20 to 30 degrees centigrade Measurement Voltage Measurement Voltage 5 min.1.2 mV +- 0.3 mV2.0 mV +- 0.3 mV 10 min.1.2 mV +- 0.3 mV2.1 mV +- 0.3 m
15、V 20 min1.4 mV +- 0.3 mV2.5 mV +- 0.3 mV 30 min1.6 mV +- 0.3 mV2.7 mV +- 0.3 mV 40 min1.7 mV +- 0.3 mV2.9 mV +- 0.3 mV 50 min1.8 mV +- 0.3 mV3.1 mV +- 0.3 mV 60 min.1.9 mV +- 0.3 mV3.2 mV +- 0.3 mV After Turning ON REMARKS -The countermeasure apply to this claim only. -With the Unit which has return
16、ed from the customer by repair, Please also readjust the following serial number. This problem apply to following week code. SR5400 / SR6400 / SR7400 apply to MZ020405xxxxxx. This improvement has been done in the production the week code MZ020406xxxxxx and after. SERVICE BULLETIN By idling, Top cove
17、r becomes very hot so that it cannot touch by hand. x for information customer complaint in case of service mandatory . See below Approved by S.NAGAO Written by WQ-19 2 817/additional rule 3 (1st Issue 2003-03-19) Date:9-Jan-2004Model: SR7400 Page:1 / 1REF.NBR:MZ04-003 Circulation:Application: Subje
18、ct: Int.ref: PHENOMENON 1) When Dolby Digital and dts decoding, the sound cut for about 0.5-second occurs at random. It doesnt occur in PCM decoding. 2) It occurs when Dolby Digital and dts are decoded with AUTO MODE. 3) Occurrence timing varies in the production time of the IC. Therefore, when this
19、 phenomenon occurs for a short time, or even if 30 minutes or more pass, it may not occurs. REASON Capacitor C281 (33pF) of the measure against EMC has influenced. By the capacitor C281, the standup of a clock pulse becomes late, DSP incorrect-detects the noise, and Auto Mute of DAC incorrect-operat
20、es. SOLUTION Capacitor C281 ( 33pF) is removed on DSP PCB. As for details, Please see page 2/2 REMARKS 1) This problem apply to the following serial number. SR7400/U1B apply to MZ000345002450 SR7400/N1B apply to MZ000351000530 SR7400/N1S apply to MZ000351000840 2) The following model has improved fr
21、om the top of mass production. SR7400/L1G SR7400/K1G SR7400/S1G SERVICE BULLETIN Sound cut (short-time) of Dolby and dts decoding. x for information customer complaint in case of service mandatory . See Below SERVICE BULLETIN REF. NBR: MZ04-003 Model : SR7400 Page2/2 SERVICE MANUAL page15 DSP PCB 1/