Jvc-UXS-77-Service-Manual电路原理图.pdf
《Jvc-UXS-77-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-UXS-77-Service-Manual电路原理图.pdf(83页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2004 Victor Company of Japan, LimitedNo.MB2302004/5COMPACT COMPONENT SYSTEMMB23020045UX-S77TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECI
2、FIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-63 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-74 ADJ
3、USTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-355 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. 1-39(SP-UXS77) (CA-UXS77) (SP-UXS77)Area suffixA - AustraliaUS - SingaporeUW - Brazil,Mexico,PeruUX - Saudi ArabiaUJ - U.S.MilitaryUN - Asean1-2 (No.MB230)SPECIFICATIONDesign and specifications are subject to change without notice.Amplifier section Output Power HIGH 40 W (20 W+ 20 W) at 4 (10% THD
5、)50 W (25 W+ 25 W) at 4 (10% MAX)LOW 40 W (20 W+ 20 W) at 4 (10% THD)50 W (25 W+ 25 W) at 4 (10% MAX)Analog input AUX Sensitivity/Impedance (at 1 kHz)400 mV/47 k (at “AUX LEVEL 1“)200 mV/47 k (at “AUX LEVEL 2“)Digital output DVD OPTICAL DIGITAL OUT -21 dBm to -15 dBm (660 nm 30 nm)VIDEO OUT Color sy
6、stem NTSCVIDEO (composite) 1 V(p-p)/75 S-VIDEO Y (luminance):1 V(p-p)/75 C (chrominance, burst):0.286 V(p-p)/75 COMPONENT (Y):1 V(p-p)/75 (PB/PR):0.7 V(p-p)/75 Speaker Terminals 4 - 16 Others AV COMPU LINK 2 (3.5)Tuner section FM tuning range 87.5 MHz - 108.0 MHzAM tuning range 531 kHz - 1 710 kHz (
7、at 9 kHz)530 kHz - 1 710 kHz (at 10 kHz)Disc player section Playable disc DVD Video/DVD Audio/CD/VCD/SVCDCD-R/CD-RW (recorded in Audio CD/Video CD/ Super Video CD/ MP3/ WMA/JPEGformat)DVD-R/DVD-RW (recorded in video format)Dynamic range 90 dBHorizontal resolution 500 linesWow and flutter Immeasurabl
8、eMP3 recording format MPEG 1/2 Audio Layer 3Max. Bit rate 320 kbpsCassette deck section Frequency response Normal (type I): 50 Hz - 14 000 HzWow and flutter 0.15% (WRMS)General Power requirement AC 110 V / AC 127 V / AC 220 V - AC 230 V,(adjustable with the voltage selector), 50 Hz/60 HzPower consum
9、ption 90 W (at operation)12 W (on standby)5.3 W (with deactivating the clock indication)Dimensions (approx.) 175 mm 237 mm 375 mm (W/H/D)Mass (approx.) 7.5 kgSpeakers Type 2-Way Bass-reflex typeSpeaker Systems Woofer: 10 cm cone 1Power handling capacity Tweeter: 4 cm cone 1HIGH: 20 WLOW: 20 WImpedan
10、ce HIGH: 4 LOW: 4 Frequency range 56 Hz - 40 000 HzSound pressure level 84 dB/WmDimensions (approx.) 145 mm 236 mm 205 mm (W/H/D)Mass (approx.) 2.3 kg each(No.MB230)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components s
11、pecially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alteratio
12、ns of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting t
13、herefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage,
14、watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplace
15、ment which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromli
16、ve parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage sho
17、ck hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do no
18、tuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good e
19、arth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor betw
20、een an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now
21、, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of
22、the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3 Ca
23、utionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams
24、, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “ “ mark nearby are criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Except the J an
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JvcUXS77ServiceManual 电路 原理图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf
LORENZ 10A 电路原理图.jpg