Philips-FWC-50-Service-Manual电路原理图.pdf
《Philips-FWC-50-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Philips-FWC-50-Service-Manual电路原理图.pdf(132页珍藏版)》请在收音机爱好者资料库上搜索。
1、Color Television ChassisFW-C50/371941ServiceServiceServiceServiceManualContents Contents4. Mechanical Instructions 00 6. Block Diagrams and Testpoints 00 7. Electrical Diagrams and PWBs Diagram PWBOVERALL WIRING DIAGRAM 1 0 FRONT BOARD SCHEMATIC DIAGRAM 2 15 CDC KEY leakage current must not exceed 0
2、.5milliamp. If a measurement is outside of thespecified limits, there is a possibility of shock hazard. The receiver should be repaired and recheckedbefore returning it to the customer.5. Repeat the above procedure with the ac plug reversed. (Note: An ac adapter isnecessary when a polarized plug is
3、used. Do not defeat the polarizing feature of the plug.)ORWith the instrument completely reassembled, plug the AC line cord directly into a 120V AC outlet. (Donot use an isolation transformer during this test.) Use a leakage current tester or ametering system that complies with American National Sta
4、ndards Institute (ANSI) C101.1 LeakageCurrent for Appliances and Underwriters Laboratories (UL) 1410, (50.7). With the instrumentAC switch first in the on position and then in the off position, measure from aknown earth ground (metal water pipe, conduit, etc.) to all exposed metalparts of the instru
5、ment (antennas, handle brackets, metal cabinet, screwheads, metallic overlays, control shafts, etc.), especially any exposed metalparts that offer an electrical return path to the chassis. Any currentmeasured must not exceed 0.5 milliamp. Reverse the instrument power cordplug in the outlet and repea
6、t the test. See graphic below.PICTURE TUBE REPLACEMENTThe primary source of X-radiation in this television receiver is the picture tube. The picture tube utilizedin this chassis is specially constructed to limit X-radiation emissions. For continued X-radiationprotection, the replacement tube must be
7、 the same type as the original, including suffix letter, or aPhilips approved type.PARTS REPLACEMENTMany electrical and mechanical parts in Philips television sets have special safety related characteristics. These characteristics are often not evident from visual inspection nor can the protection a
8、fforded bythem necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. The use of a substitute part which does not have the same safety characteristics as the Philipsrecommended replacement part shown in this service manual may create shock, fire, or other haz
9、ardsTV SAFETY NOTESSAFETY CHECKSIMPLOSION X-RADIATIONPICTURE TUBE REPLACEMENT PARTS REPLACEMENT WARNINGBefore removing the CRT anode cap, turn the unit OFF and short the HIGH VOLTAGE to the CRT DAGground.SERVICE NOTE: The CRT DAG is not at chassis ground.TV-VCR COMBI SAFETY NOTESIMPORTANT SAFETY PRE
10、CAUTIONSPrior to shipment from the factory, our products are strictly inspected for recognized product safety andelectrical codes of the countries in which they are to be sold. However, in order to maintain suchcompliance, it is equally important to implement the following precautions when a set is
11、being serviced.SAFETY PRECAUTIONS FOR TV CIRCUITS1. Before returning an instrument to the customer, always make a safety check of the entire instrument,including, but not limited to, the following items:a. Be sure that no built-in protective devices are defective or have been defeated during servici
12、ng.(1) Protective shields are provided on this chassis to protect both the technician and the customer. Correctly replace all missing protective shields, including any removed for servicing convenience. (2)When reinstalling the chassis and/or other assembly in the cabinet, be sure to put back in pla
13、ce allprotective devices, including but not limited to, nonmetallic control knobs, insulating fishpapers,adjustment and compartment covers/shields, and isolation resistor/capacitor networks. Do notoperate this instrument or permit it to be operated without all protective devices correctly installeda
14、nd functioning. Servicers who defeat safety features or fail to perform safety checks may be liablefor any resulting damage.b. Be sure that there are no cabinet openings through which an adult or child might be able to inserttheir fingers and contact a hazardous voltage. Such openings include, but a
15、re not limited to, (1)spacing between the picture tube and the cabinet mask, (2) excessively wide cabinet ventilation slots,and (3) an improperly fitted and/or incorrectly secured cabinet back cover.c. Do a LEAKAGE CURRENT CHECK ANY MEASUREMENTS NOT WITHIN THE LIMITS SPECIFIED HEREIN INDICATE A POTE
16、NTIAL SHOCKHAZARD THAT MUST BE ELIMINATED BEFORE RETURNING THE INSTRUMENT TO THE CUSTOMEROR BEFORE CONNECTING THE ANTENNA OR ACCESSORIES.d. X-Radiation and High Voltage Limits - Because the picture tube is the primary potentialsource of X-radiation in solid-state TV receivers, it is specially constr
17、ucted to prohibit X-radiationemissions. For continued X-radiation protection, the replacement picture tube must be the same typeas the original. Also, because the picture tube shields and mounting hardware perform an X-radiationprotection function, they must be correctly in place. High voltage must