Yamaha-RX-497-Service-Manual电路原理图.pdf
《Yamaha-RX-497-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Yamaha-RX-497-Service-Manual电路原理图.pdf(46页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel. It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA Products, are already known and understood by the users, and have therefore no
2、t been restated. WARNING:Failure to follow appropriate service and safety procedures when servicing this product may result in personal injury, destruction of expensive components, and failure of the product to perform as specified. For these reasons, we advise all YAMAHA product owners that any ser
3、vice required should be performed by an authorized YAMAHA Retailer or the appointed service representative. IMPORTANT:The presentation or sale of this manual to any individual or firm does not constitute authorization, certification or recognition of any applicable technical capabilities, or establi
4、sh a principle-agent relationship of any form. The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and service departments of YAMAHA are continually striving to improve YAMAHA products. Modifications are, therefore, inevitable
5、 and specifications are subject to change without notice or obligation to retrofit. Should any discrepancy appear to exist, please contact the distributors Service Division. WARNING:Static discharges can destroy expensive components. Discharge any static electricity your body may have accumulated by
6、 grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss). IMPORTANT:Turn the unit OFF during disassembly and part replacement. Recheck all work before you apply power to the unit. IMPORTANT NOTICE 100977 SERVICE MANUAL STEREO RECEIVER AMP ADJUSTMENT . . . . .
7、 . . . . . . . . . . . . . . . . . . . . 16 IC DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1718 DISPLAY DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 PIN CONNECTION DIAGRAM . . . . . . . . . . . . . . . . . 20 PRINTED CIRCUIT BOARD . . . . . . . . . . . .
8、 . . . . 2127 BLOCK DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 SCHEMATIC DIAGRAM . . . . . . . . . . . . . . . . . . . 2932 PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3343 REMOTE CONTROL RAX100/RAX101 . . . . . . . 4445 I CONTENTS TO SERVICE PERSONNEL
9、. . . . . . . . . . . . . . . . . . . . 2 IMPEDANCE SELECTOR . . . . . . . . . . . . . . . . . . . . . . 3 FRONT PANELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 REAR PANELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 REMOTE CONTROL PANELS . . . . . . . . . . . . . .
10、 . . . . 5 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 67 INTERNAL VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 DISASSEMBLY PROCEDURES . . . . . . . . . . . . . . . . . 8 SELF DIAGNOSIS FUNCTION . . . . . . . . . . . . . . . 915 DPX-1200RX-497 RX-497 2005 Y
11、AMAHA CORPORATION. All rights reseved. This manual is copyrighted by YAMAHA and may not be copied or redistributed either in print or electronically without permission. 05.11 2 RX-497 RX-497 I TO SERVICE PERSONNEL 1. Critical Components Information Components having special characteristics are marke
12、d Z and must be replaced with parts having specifications equal to those originally installed. 2. Leakage Current Measurement (For 120V Models Only) When service has been completed, it is imperative to verify that all exposed conductive surfaces are properly insulated from supply circuits. GMeter im
13、pedance should be equivalent to 1500 ohms shunted by 0.15F. AC LEAKAGE TESTER OR EQUIVALENT EQUIPMENT UNDER TEST INSULATING TABLE WALL OUTLET GLeakage current must not exceed 0.5mA. GBe sure to test for leakage with the AC plug in both polarities. WARNING: CHEMICAL CONTENT NOTICE! The solder used in
14、 the production of this product contains LEAD. In addition, other electrical/electronic and/or plastic (where applicable) components may also contain traces of chemicals found by the California Health and Welfare Agency (and possibly other entities) to cause cancer and/or birth defects or other repr
15、oductive harm. DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REASON WHATSOEVER! Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose eyes to solder/flux vapor! If you come in contact with sold
16、er or components located inside the enclosure of this product, wash your hands before handling food. About Lead Free Solder The P.C.B.s installed in this unit are soldered using the following solder. “CAUTION” “F251, F252 : FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 8
17、A, 125V FUSE.” CAUTION F251, F252 : REPLACE WITH SAME TYPE 8A, 125V FUSE. ATTENTION F251, F252 : UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 8A, 125V. A V SI DE ASI DE B FUNCTI ON P. C. B.Lead Free Solder OPERATI ON P. C. B.Lead Free Solder MAI N P. C. B.Lead Free Solder XM P. C. B.Lead Free Sol
18、derLead Free Solder Side A Side B SMT REFLOW Process MI FLOW Process Solder Dip Among some types of lead free solder currently available, it is recommended to use one of the following types for the repair work. Sn + Ag + Cu (tin + silver + copper) Sn + Cu (tin + copper) Sn + Zn + Bi (tin + zinc + bi
19、smuth) Caution: 1. As the melting point temperature of the lead free solder is about 30C to 40C (50F to 70F) higher than that of the lead solder, be sure to use a soldering iron suitable to each solder. 2. If lead solder must be used, be sure to remove lead free solder from each terminal section of
20、the parts to be replaced and from the area around it completely before soldering, or make sure that the lead free solder and lead solder melt together fully. 3 RX-497 DPX-1200RX-497 I IMPEDANCE SELECTOR WARNING: Do not change the setting of the IMPEDANCE SELECTOR switch when the unit power is switch
21、ed on, as doing so may damage the unit. IMPEDANCE SELECTOR I FRONT PANELS M U, C models M R, A, G, E, L models 4 RX-497 RX-497 I REAR PANELS M U, C models M R model M A model 5 RX-497 DPX-1200RX-497 M G, E models M L model I REMOTE CONTROL PANELS M RAX100 (U, C models)M RAX101 (R, A, G, E, L models)
22、 6 RX-497 RX-497 I SPECIFICATIONS AUDIO SECTION Minimum RMS Output Power (Power Amp. Section) L/R, 20 Hz to 20 kHz, 0.04% THD, 8 ohms . . . . . . .75 W + 75 W Dynamic Power Per Channel (IHF) 8/6/4/2 ohms . . . . . . . . . . . . . . . . . . . . . . .105/125/150/178 W Maximum Power Per Channel (G, E m
23、odels) 1 kHz, 0.7 % THD, 4 ohms . . . . . . . . . . . . . . . . . . . . . . . .105 W IEC Power (G, E models) 1 kHz, 0.04% THD, 8 ohms . . . . . . . . . . . . . . . . . . . . . . . .84 W Maximum Power (EIAJ) (R, L models) 1 kHz, 10% THD, 8 ohms . . . . . . . . . . . . . . . . . . . . . . . . .115 W P
24、ower Band Width L/R, 0.08% THD, 35 W, 8 ohms . . . . . . . . . . . .10 Hz to 50 kHz Damping Factor 20 Hz to 20 kHz, SPEAKER-A, 8 ohms . . . . . . . . .150 or more Input Sensitivity/Input Impedance PHONO MM . . . . . . . . . . . . . . . . . . . . . . . . .3.0 mV/47 k-ohms CD, etc. . . . . . . . . . .
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Yamaha RX 497 Service Manual 电路 原理图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


