1、SERVICE MANUAL D&M Holdings Inc. MODELJPE3E2EKEAE1E1KE1C MC2000PPP DJ Controller Ver. 3 S0620-0V03DM/DG1302 Some illustrations using in this service manual are slightly different from the actual set. Please use this service manual with referring to the operating instructions without fail. For purpos
2、es of improvement, specifications and design are subject to change without notice. Please refer to the MODIFICATION NOTICE. RadioFans.CN 2 CONTENTS SAFETY PRECAUTIONS .3 NOTE FOR SCHEMATIC DIAGRAM .4 TECHNICAL SPECIFICATIONS .5 DIMENSION .5 DISASSEMBLY .6 SPECIAL MODE .12 1. Special mode setting .12
3、 2. Version Up mode .12 3. Version indicate mode .13 4. Adjusting mode of the touch sense sensitivity .14 5. Initialization of parameters .14 6. Adjusting interval time of MIDI command transmission .15 7. SW, VOLUME, ENCODER and LED TEST .16 WHEN THE MICROPROCESSOR IS REPLACED WITH A NEW ONE .23 PRO
4、CEDURE FOR UPGRADING THE VERSION OF THE FIRMWARE .23 TROUBLE SHOOTING .32 WIRING DIAGRAM .41 BLOCK DIAGRAM .43 POWER BLOCK DIAGRAM .44 Level DIAGRAM .45 PRINTED WIRING BOARDS .46 CONTROL .46 I/O .48 SCHEMATIC DIAGRAMS (1/2) .50 CONTROL UNIT .50 I/O UNIT .51 EXPLODED VIEW .52 PARTS LIST OF EXPLODED V
5、IEW .53 PACKING VIEW .55 PARTS LIST OF PACKING & ACCESSORIES .55 SEMICONDUCTORS .57 1. ICs .57 PARTS LIST OF P.C.B. UNIT .68 CONTROL P.C.B ASSY .68 I/O P.C.B ASSY.71 CROS FADER P.C.B ASSY .75 PHONE P.C.B ASSY.75 RadioFans.CN 3 SAFETY PRECAUTIONS The following items should be checked for continued pr
6、otection of the customer and the service technician. LEAKAGE CURRENT CHECK Before returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to e
7、ither side of the power cord is less than 460 kohms, the set is defective. Be sure to test for leakage current with the AC plug in both polarities, in addition, when the sets power is in each state (on, off and standby mode), if applicable. CAUTION Please heed the following cautions and instructions
8、 during servicing and inspection. Heed the cautions! Cautions which are delicate in particular for servicing are labeled on the cabinets, the parts and the chassis, etc. Be sure to heed these cautions and the cautions described in the handling instructions. Cautions concerning electric shock! (1) An
9、 AC voltage is impressed on this set, so if you touch internal metal parts when the set is energized, you may get an electric shock. Avoid getting an electric shock, by using an isolating transformer and wearing gloves when servicing while the set is energized, or by unplugging the power cord when r
10、eplacing parts, for example. (2) There are high voltage parts inside. Handle with extra care when the set is energized. Caution concerning disassembly and assembly! Through great care is taken when parts were manufactured from sheet metal, there may be burrs on the edges of parts. The burrs could ca
11、use injury if fingers are moved across them in some rare cases. Wear gloves to protect your hands. Use only designated parts! The sets parts have specific safety properties (fire resistance, voltage resistance, etc.). Be sure to use parts which have the same properties for replacement. The burrs hav
12、e the same properties. In particular, for the important safety parts that are indicated by the z mark on schematic diagrams and parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as they were originally placed! For safety seasons, some parts use tapes, tub
13、es or other insulating materials, and some parts are mounted away from the surface of printed circuit boards. Care is also taken with the positions of the wires by arranging them and using clamps to keep them away from heating and high voltage parts, so be sure to set everything back as it was origi
14、nally placed. Make a safety check after servicing! Check that all screws, parts and wires removed or disconnected when servicing have been put back in their original positions, check that no serviced parts have deteriorate the area around. Then make an insulation check on the external metal connecto
15、rs and between the blades of the power plug, and otherwise check that safety is ensured. (Insulation check procedure) Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and on the power. Using a 500V insulation resistance tester, check that the insulation resistance va
16、lue between the inplug and the externally exposed metal parts (antenna terminal, headphones terminal, input terminal, etc.) is 1M or greater. If it is less, the set must be inspected and repaired. Many of the electric and the structural parts used in the set have special safety properties. In most c
17、ases these properties are difficult to distinguish by sight, and the use of replacement parts with higher ratings (rated power and withstand voltage) does not necessarily guarantee that safety performance will be preserved. Parts with safety properties are indicated as shown below on the wiring diag
18、rams and the parts list in this service manual. Be sure to replace them with the parts which have the designated part number. (1) Schematic diagrams .Indicated by the z mark. (2) Parts lists .Indicated by the z mark. The use of parts other than the designated parts could cause electric shocks, fires
19、 or other dangerous situations. CAUTION Concerning important safety parts RadioFans.CN 4 NOTE FOR SCHEMATIC DIAGRAM WARNING: Parts indicated by the z mark have critical characteristics. Use ONLY replacement parts recommended by the manufacturer. CAUTION: Before returning the set to the customer, be
20、sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective. WARNING: DO NOT return the set to the custome
21、r unless the problem is identified and remedied. NOTICE: ALL RESISTANCE VALUES IN OHM. k=1,000 OHM / M=1,000,000 OHM ALL CAPACITANCE VALUES ARE EXPRESSED IN MICRO FARAD, UNLESS OTHERWISE INDICATED. P INDICATES MICRO-MICRO FARAD. EACH VOLTAGE AND CURRENT ARE MEASURED AT NO SIGNAL INPUT CONDITION. CIR