JVC-HXZ9-cs-sm维修电路原理图.pdf
《JVC-HXZ9-cs-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-HXZ9-cs-sm维修电路原理图.pdf(77页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL COPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LIMITED No.22066 2003/7 COMPACT COMPONENT SYSTEM 2206620037 HX-Z9 TABLE OF CONTENTS 1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
2、2SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
3、 4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-33 5TROUBLE SHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、 . . . 1-39 Area Suffix UW - Brazil,Mexico,Peru RadioFans.CN 收音机爱 好者资料库 1-2 (No.22066) SPECIFICATION Design and specifications are subject to change without notice. Amplifier section Output Power (IEC 268-3) SUBWOOFERS75 W per channel, min. RMS, both channels driven into 6 at 63 Hz with no more than
5、 0.9% total harmonic distortion. MAIN SPEAKERS30 W per channel, min. RMS, both channels driven into 6 at 1 kHz with no more than 0.9% total harmonic distortion. Audio input sensitivity/Impedance(Measured at 1 kHz, with tape recording signal 300 mV) AUX390 mV/50 k Speakers/ Impedance SUBWOOFERS6 - 16
6、 MAIN SPEAKERS6 - 16 SURROUND SPEAKERS 16 - 32 TunerFM tuning range87.50 MHz - 108.00 MHz AM tuning range At 9 kHz intervals531 kHz - 1 710 kHz At 10 kHz intervals530 kHz - 1 710 kHz CD playerCD capacity3 CDs Dynamic range85 dB Signal-to-noise ratio90 dB Wow and flutterImmeasurable Cassette deckFreq
7、uency response Normal (type I)50 Hz - 14 000 Hz Wow and flutter0.15% (WRMS) GeneralPower requirementAC 110 V / AC 127 V / AC 220 V / AC 230 V - AC 240 V (adjustable with the voltage selector), 50 Hz / 60 Hz Power consumption205 W (in operation) 23 W (on standby with Ecology Mode off) Less than 3.5 W
8、 (on standby with Ecology Mode on) Dimensions (approx.)205 mm 370 mm 370 mm (W/H/D) Mass (approx.)10.0 kg Supplied accessoriesSee page 6. RadioFans.CN 收音机爱 好者资料库 (No.22066)1-3 SECTION 1 PRECAUTION 1.1Safety Precautions (1) This design of this product contains special hardware and many circuits and c
9、omponents specially for safety purpos- es. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be per- formed by qualified personnel on
10、ly. (2) Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or prope
11、rty damage resulting therefrom. (3) Many electrical and mechanical parts in the products have special safety-related characteristics. These characteris- tics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by us- ing replacement components
12、 rated for higher voltage, watt- age, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Ser- vice Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual
13、. The use of a substitute replacement which does not have the same safety charac- teristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards. (4) The leads in the products are routed and dressed with ties, clamps, tubings, barrie
14、rs and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to
15、normal, after reassem- bling. (5) Leakage shock hazard testing After reassembling the product, always perform an isola- tion check on the exposed metal parts of the product (an- tenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe t
16、o operate without danger of electrical shock.Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particular- ly any exposed metal part h
17、aving a return path to the chassis, to a known good earth ground. Any leakage cur- rent must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 per volt or more sensitivity in the following manner. Connect a 1,500
18、 10W resistor paralleled by a 0.15F AC-type capacitor between an ex- posed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to
19、the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2Warning (1) This equipment has been designed and manufactured to meet i
20、nternational safety standards. (2) It is the legal responsibility of the repairer to ensure that these safety standards are maintained. (3) Repairs must be made in accordance with the relevant safety standards. (4) It is essential that safety critical components are replaced by approved parts. (5) I
21、f mains voltage selector is provided, check setting for local voltage. 1.3Caution Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of pre- forming repair of this system. 1.4Critical parts for safety In regard with component
22、 parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the mark nearby are critical for safety. When replacing them, be sure to use the parts of the same type and r
23、ating as specified by the manufacturer. (This regulation dose not Except the J and C version) Good earth ground Place this probe on each exposed metal part. AC VOLTMETER (Having 1000 ohms/volts, or more sensitivity) 1500 10W 0.15 F AC TYPE 1-4 (No.22066) 1.5Preventing static electricity Electrostati
24、c discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs. 1.5.1 Grounding to prevent damage by static electricity Static electricity in