sony_MDX-C800REC_a_service_manual 维修电路图.pdf
《sony_MDX-C800REC_a_service_manual 维修电路图.pdf》由会员分享,可在线阅读,更多相关《sony_MDX-C800REC_a_service_manual 维修电路图.pdf(8页珍藏版)》请在收音机爱好者资料库上搜索。
1、1 SUPPLEMENT-1 File this supplement with the service manual. Subject : Electrical Adjustments SERVICE MANUAL MDX-C800REC US Model Canadian Model 收音机爱好者资料库 Ra d i o Fa n s .CN 2 TEST MODE This set has the test mode functionality. The test mode should be always set before performing adjustments. 1. In
2、put the specified voltage (14.4 V) to the ACC and BATT terminals. 2. “1:00” is displayed on the LCD display. 3. Press 4 key. 4. Press 5 key. 5. Press 1 key for more than 2 seconds. 6. All segments are lit on the LCD display entering the test mode. 1. Press OFF key. DISPLAY TEST 1. Once the test mode
3、 is set, each pressing of the DSPL key will cause the LCD display to change as follows: All segments ON Press DSPL key. Half segments ON (1) Press DSPL key. Half segments ON (2) (The other half segments that were OFF in (1) are ON.) Press DSPL key. All segments OFF Press DSPL key. TEST MODE STRUCTUR
4、E 1. Set the test mode. 2. Insert a disc and press 5 key. 3. Each time 6 key is pressed, the mode will change as follows: ADJUSTMENT mode “SHUF” indication off Press 6 key. PLAY mode “SHUF1” indication is lit. Press 6 key. REC mode “SHUF2” indication is lit. Press 6 key. Unused mode “SHUF ALL” indic
5、ation is lit. Press 6 key. ELECTRICAL ADJUSTMENT ADJUSTMENT mode: SHUF indication off KeyDescription of test 2Laser power adjustment mode 3Traverse adjustment mode 4Focus bias adjustment mode 5STOP 6Switch the mode ENTERCLV jitter measurement DSPLSelect the display PLAY mode: SHUF1 KeyDescription of
6、 test 2Laser power check mode 3Focus + CLV ON 4Tracking servo ON/OFF 5STOP 6Switch the mode ENTERCPLAY mode (middle/outer/inner area) DSPLSelect the display REC mode: SHUF2 KeyDescription of test 2Laser power check mode 3Focus + CLV ON 4Tracking servo ON/OFF 5STOP 6Switch the mode ENTERCREC mode (mi
7、ddle/outer/inner area) DSPLSelect the display Unused mode: SHUF ALL 收音机爱好者资料库 Ra d i o Fa n s .CN 3 NOTES FOR ADJUSTMENT 1. Perform the following adjustments as listed when the optical pick- up and IC400, IC402 and/or IC440 in the MD SERVO board have been replaced: (1) Laser power adjustment (2) Tra
8、verse adjustment (3) Focus bias adjustment (4) CD error rate check (5) MO error rate check 2. Set the test mode to perform these adjustments. Release the test mode after the adjustments are completed. 3. Perform the adjustments in the order that they are listed. 4. Use the following jigs and measuri
9、ng equipment: Test disc (special disc for playback) TDYS-1 (Part No.: 4-963-646-01) Laser power meter LPM-8001 (Part No.: J-2501-046-A) Oscilloscope (Measure after the probe is calibrated.) Digital voltmeter 5. When observing multiple signals with an oscilloscope or other equipment, take care to pre
10、vent connection between VC and ground in the oscilloscope. (Otherwise, VC and ground are shorted.) PREPARING A CONTINUOUSLY RECORDED DISC This disc is used for focus bias adjustment and error rate check. This disc is prepared as follows: 1. Set the test mode. (See page 2.) 2. Insert a commercial dis
11、c (blank) and press 5 key. 3. Press 6 key twice to set the REC mode. (Verify that the “SHUF2” indication is lit on the LCD display.) 4. Verify that no number is displayed at the disc No. indicator. If any number is displayed, repeatedly press DSPL key until the number disappears (only two digits are
12、 displayed). 5. Press ENTER key three times and verify that there is no disc number displayed (the disc is recorded from the inner area). If “3” or “7” is displayed, press ENTER key again to clear the indicator. LCD display 6. Record the data until the disc number indicator shows “9” and then press
13、5 key to stop recording. 7. Press Z key and take out the disc. The continuously recorded disc for focus bias adjustment and error rate check is now prepared. Note: Take care to prevent vibrations during continuous recording. SHUF 2 Disc No. indicator REC mode 收音机爱好者资料库 Ra d i o Fa n s .CN 4 KMS-263A
14、 2 7 X 9 3 B 0 8 2 5 (Optical pick-up label) In this case, Iop = 82.5 mA Iop (mA) = Reading on the digital voltmeter (mV)/1 () For the measurement points, see page 7. LASER POWER ADJUSTMENT Connection: Procedure: 1. Connect a digital voltmeter between TP (I+3V) and TP (IOP). 2. Set the test mode. (S
15、ee page 2.) 3. Insert a laser power meter into the disc insertion port and press 5 key. 4. Press 2 key. LCD display + optical pick-up objective lens laser power meter digital voltmeter MD servo board TP (I+3V) TP (IOP) 5. Use DISC + or DISC key to adjust so that the reading on the laser power meter