sony_MDS-JE440_service_manual 维修电路图.pdf
《sony_MDS-JE440_service_manual 维修电路图.pdf》由会员分享,可在线阅读,更多相关《sony_MDS-JE440_service_manual 维修电路图.pdf(64页珍藏版)》请在收音机爱好者资料库上搜索。
1、MDS-JE440 SPECIFICATIONS SERVICE MANUAL MINIDISC DECK Model Name Using Similar MechanismNEW MD Mechanism TypeMDM-7A Optical Pick-up TypeKMS-260B/J1N US Model Canadian Model AEP Model UK Model E Model Australian Model US and foreign patents licensed form Dolby Laboratories Licensing Corporation. Inpu
2、ts Outputs SystemMiniDisc digital audio system DiscMiniDisc LaserSemiconductor laser ( = 780 nm) Emission duration: continuous Laser output MAX 44.6 W1) 1) This output is the value measured at a distance of 200 mm from the objective lens surface on the Optical Pick-up Block with 7 mm aperture. Laser
3、 diode Material: GaAlAs Revolutions (CLV)400 rpm to 900 rpm Error correction ACIRC (Advanced Cross Interleave Reed Solomon Code) Sampling frequency 44.1 kHz CodingATRAC (Adaptive TRansform Acoustic Coding)/ATRAC 3 Modulation systemEFM (Eight-to-Fourteen Modulation) Number of channels 2 stereo channe
4、ls Frequency response 5 to 20,000 Hz 0.3 dB Signal-to-noiseratio Over 96 dB during play Wow and flutter Below measurable limit ANALOG IN Jack type: phono Impedance: 47 k Rated input: 500 mVrms Minimum input: 125 mVrms DIGITAL INConnector type: square optical Impedance: 660 nm (optical wave length) A
5、NALOG OUTJack type: phono Rated output: 2 Vrms (at 50 k) Load impedance: over 10 k DIGITAL OUTConnector type: square optical Rated output: 18 dBm Load impedance: 660 nm (optical wave length) Continued on next page 收音机爱好者资料库 Ra d i o Fa n s .CN 2 SELF-DIAGNOSIS FUNCTION The self-diagnosis function co
6、nsists of error codes for customers which are displayed automatically when errors occur, and error codes which show the error history in the test mode during servicing. For details on how to view error codes for the customer, refer to the following box in the instruction manual. For details on how t
7、o check error codes during servicing, refer to the following “Procedure for using the Self- Diagnosis Function (Error History Display Mode)”. Procedure for using the Self-Diagnosis Function (Error History Display Mode). Note: Perform the self-diagnosis function in the “error history display mode” in
8、 the test mode. The following describes the least required procedure. Be careful not to enter other modes by mistake. If you set other modes accidentally, press the MENU/NO button to exit the mode. Self-diagnosis function The decks self-diagnosis function automatically checks the condition of the MD
9、 deck when an error occurs, then issues a three- or five-digit code and an error message on the display. If the code and message alternate, find them in the following table and perform the indicated countermeasure. Should the problem persist, consult your nearest Sony dealer. Three- or five- digit c
10、ode/ Message Cause/Remedy C11/Protected The inserted MD is record-protected. , Take out the MD and close the record- protect slot (page 14). C12/Cannot Copy You tried to record a CD with a format that the external device connected to the deck does not support, such as CD-ROM or video CD. , Remove th
11、e disc and insert a music CD. C13/REC Error The recording was not made properly. , Set the deck in a stable surface, and repeat the recording procedure. The inserted MD is dirty (with smudges, fingerprints, etc.), scratched, or substandard in quality. , Replace the disc and repeat the recording proc
12、edure. C13/Read Error The deck could not read the TOC on the MD properly. , Take out the MD and insert it again. C14/Toc Error The deck could not read the TOC on the MD properly. , Insert another disc. , If possible, erase all the tracks on the MD (page 32). C41/Cannot Copy The sound source is a cop
13、y of commercially available music software, or you tried to record a CD-R (Recordable CD). , The Serial Copy Management System prevents making a digital copy (page 52). You cannot record a CD-R. C71/Din Unlock The sporadic appearance of this message is caused by the digital signal being recorded. Th
14、is will not affect the recording. While recording from a digital component connected through the DIGITAL IN connector, the digital connecting cable was unplugged or the digital component turned off. , Connect the cable or turn the digital component back on. E0001/ MEMORY NG There is an error in the
15、internal data that the deck needs in order to operate. , Consult your nearest Sony dealer. E0101/ LASER NG There is a problem with the optical pickup. , The optical pick-up may have failed. Consult your nearest Sony dealer. Three- or five- digit code/ Message Cause/Remedy General Power requirements
16、Supplied accessories Audio connecting cords (2) Optical cable (1) Remote commander (remote) (1) R6 (size-AA) batteries (2) US and foreign patents licensed from Dolby Laboratories. Design and specifications are subject to change without notice. Where purchasedPower requirements US, Canadian120 V AC,
17、60 Hz AEP, UK, CIS220 230 V AC, 50/60 Hz Singapore, Malaysia 110 120 or 220 240 V AC selectable, 50/60 Hz Power consumption 15 W Dimensions (approx.) 430 95 285 mm (17 33/4 111/4 in.) (w/h/d) incl. projecting parts and controls Mass (approx.)3.0 kg (6 lbs 10 oz) Australian240 V AC, 50/60 Hz Hong Kon
18、g220 240 V AC, 50/60 Hz 收音机爱好者资料库 Ra d i o Fa n s .CN 3 1. While pressing the AMS knob and x button, connect the power plug to the outlet, and release the AMS knob and x button. When the test mode is set, “Check” will be displayed. 2. Rotate the AMS knob and when “Service” is displayed, press the YE
19、S button. 3. Rotate the AMS knob and display “Err Display”. 4. Pressing the YES button sets the error history mode and displays “op rec tm”. 5. Select the contents to be displayed or executed using the AMS knob. 6. Pressing the AMS knob will display or execute the contents selected. 7. Pressing the
20、AMS knob another time returns to step 4. 8. Pressing the MENU/NO button displays “Err Display” and exits the error history mode. 9. To exit the test mode, press the REPEAT button. The unit sets into the STANDBY state, the disc is ejected, and the test mode ends. ITEMS OF ERROR HISTORY MODE ITEMS AND
21、 CONTENTS Selecting the Test Mode Display op rec tm op play tm spdl rp tm retry err total err err history retry adrs er refresh op change spdl change History Displays the total recording time. When the total recording time is more than 1 minute, displays the hour and minute When less than 1 minute,
22、displays “Under 1 min” The display time is the time the laser is set to high power, which is about 1/4 of the actual recording time. Displays the total playback time. When the total playback time is more than 1 minute, displays the hour and minute When less than 1 minute, displays “Under 1 min” Disp