sony_mdsja20es_service 维修电路图.pdf
《sony_mdsja20es_service 维修电路图.pdf》由会员分享,可在线阅读,更多相关《sony_mdsja20es_service 维修电路图.pdf(84页珍藏版)》请在收音机爱好者资料库上搜索。
1、MICROFILM SERVICE MANUAL MINIDISC DECK US Model Canadian Model AEP Model UK Model SPECIFICATIONS MDS-JA20ES U.S. and foreign patents licensed form Dolby Laboratories Licensing Corporation. Model Name Using Similar MechanismNEW MD Mechanism TypeMDM-6A Base Unit NameMBU-5C Optical Pick-up NameKMS-260A
2、/J1N SystemMiniDisc digital audio system DiscMiniDisc LaserSemiconductor laser (=780nm) Emission duration: continuous Laser outputLess than 44.6 W* * This output is the value measured at a distance of 200 mm from the objective lens surface on the Optical Pick-up Block with 7 mm aperture. Laser diode
3、 propertiesMaterial: GaAIAs Revolutions (CLV)400 rpm to 900 rpm Error correctionAdvanced Cross Interleave Reed Solomon Code (ACIRC) Sampling frequency44.1 kHz CodingAdaptive Transform Acoustic Coding (ATRAC) Modulation systemEFM (Eight-to-Fourteen Modulation) Number of channels2 stereo channels Freq
4、uency response5 to 20,000 Hz 0.3 dB Signal-to-noise ratioOver 102 dB during playback Wow and flutterBelow measurable limit Inputs JackInputRatedMinimum typeimpedanceinputinput LINE (ANALOG) Phono47 kilohms500 mVrms 125 mVrms INjacks DIGITAL INSquareOptical wave OPT 1opticallength: connector660 nm ja
5、ck DIGITAL INSquareOptical wave OPT 2opticallength: connector660 nm jack DIGITAL INPhono75 ohms0.5 Vp-p, COAXIALjack20% Outputs Jack typeRated outputLoad impedance PHONESStereo28 mW32 ohms phone jack LINE (ANALOG) Phono2 VrmsOver OUTjacks(at 50 kilohms)10 kilohms DIGITAL OUTSquare18 dBmOptical wave
6、OPTICALopticallength: connector660 nm jack DIGITAL OUTPhono0.5 Vp-p75 ohms COAXIALjack(at 75 ohms) Coutinued on next page Photo: GOLD Type 收音机爱好者资料库 Ra d i o Fa n s .CN 2 General Power requirements Where purchasedPower requirements AEP, UK220 230 V AC, 50/60 Hz US, Canadian120 V AC, 60 Hz Power cons
7、umption18 W Dimensions (approx.) (w/h/d) incl.projecting parts and controls 430 125 345 mm (17 5 133/4 in) Mass (approx.)7.8 kg (17 lb 3 oz) Supplied accessories Audio connecting cords (2) Remote commander (remote) RM-D19M (1) R6 (size-AA) batteries (2) Design and specifications are subject to chang
8、e without notice. SELF-DIAGNOSIS FUNCTION The self-diagnosis function consists of error codes for customers which are displayed automatically when errors occur, and error codes which show the error history in the test mode during servicing. For details on how to view error codes for the customer, re
9、fer to the following box in the instruction manual. For details on how to check error codes during servicing, refer to the following “Procedure for using the Self-Diagnosis Function (Error History Display Mode)”. Procedure for using the Self-Diagnosis Function (Error History Display Mode). Note: Per
10、form the self-diagnosis function in the “error history display mode” in the test mode. The following describes the least required procedure. Be careful not to enter other modes by mistake. If you set other modes accidentally, press the MENU/NO button to exit the mode. 1.While pressing the AMS knob a
11、nd p button, connect the power plug to the outlet, and release the AMS knob and p button. 2.Rotate the AMS knob and when “Service” is displayed, press the YES button. 3.Rotate the AMS knob and display “ERR DP MODE”. 4.Pressing the YES button sets the error history mode and displays “total rec”. 5.Se
12、lect the contents to be displayed or executed using the AMS knob. 6.Pressing the AMS knob will display or execute the contents selected. 7.Pressing the AMS knob another time returns to step 4. 8.Pressing the MENU/NO button displays “ERR DP MODE” and exits the error history mode. 9.To exit the test m
13、ode, press the REPEAT button. The unit sets into the STANDBY state, the disc is ejected, and the test mode ends. 收音机爱好者资料库 Ra d i o Fa n s .CN 3 Items of Error History Mode Items and Contents Selecting the Test Mode DisplayDetails of History E00No error E01Disc error. PTOC cannot be read (DISC eject
14、ed) E02Disc error. UTOC error (DISC not ejected) E03Loading error E04Address cannot be read (Servo has deviated) Table of Error Codes Error CodeError CodeDetails of Error total recDisplays the recording time. Displayed as “rh”. The displayed time is the total time the laser is set to the high power
15、state. This is about 1/4 of the actual recording time. The time is displayed in decimal digits from 0h to 65535h. total playDisplays the play time. Displayed as “ph”. The time displayed is the total actual play time. Pauses are not counted. The time is displayed in decimal digits from 0h to 65535h.
16、retry errDisplays the total number of retries during recording and number of retry errors during play. Displayed as “r p”. “r” indicates the retries during recording while “p” indicates the retry errors during play. The number of retries and retry errors are displayed in hexadecimal digits from 00 t
17、o FF. total errDisplays the total number of errors. Displayed as “total ”. The number of errors is displayed in hexadecimal digits from 00 to FF. err historyDisplays the 10 latest errors. Displayed as “0 E”. indicates the history number. The smaller the number, the more recent is the error. (00 is t
18、he latest). indicates the error code. Refer to the following table for the details. The error history can be switched by rotating the AMS knob. er refreshMode which erases the “retry err”, “total err”, and “err history” histories. When returning the unit to the customer after completing repairs, per
19、form this to erase the past error history. After pressing the AMS button and “er refresh?” is displayed, press the YES button to erase the history. “Complete!” will be displayed momentarily. Be sure to check the following when this mode has been executed. The data has been erased. The mechanism oper
20、ates normally when recording and play are performed. tm refreshMode which erases the “total rec” and “total play” histories. These histories serve as approximate indications of when to replace the optical pickup. If the optical pickup has been replaced, perform this operation and erase the history.
21、After pressing the AMS button and “tm refresh?” is displayed, press the YES button to erase the history. “Complete!” will be displayed momentarily. Be sure to check the following when this mode has been executed. The data has been erased. The mechanism operates normally when recording and play are p
22、erformed. E05FOK has deviated E06Cannot focus (Servo has deviated) E07Recording retry E08Recording retry error E09Playback retry error (Access error) E0APlayback retry error (C2 error) Details of Error 收音机爱好者资料库 Ra d i o Fa n s .CN 4 SECTION 1 SERVICING NOTES SAFETY CHECK-OUT After correcting the or
23、iginal service problem, perform the follow- ing safety check before releasing the set to the customer: Check the antenna terminals, metal trim, “metallized” knobs, screws, and all other exposed metal parts for AC leakage. Check leakage as described below. LEAKAGE TEST The AC leakage from any exposed
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- sony_mdsja20es_service 维修电路图 维修 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf