SONY MZ-G755 维修电路图.pdf
《SONY MZ-G755 维修电路图.pdf》由会员分享,可在线阅读,更多相关《SONY MZ-G755 维修电路图.pdf(52页珍藏版)》请在收音机爱好者资料库上搜索。
1、1 SERVICE MANUAL FM/AM PORTABLE MINIDISC RECORDER Model Name Using Similar MechanismMZ-G750/R700 Mechanism TypeMT-MZR700-172 Optical Pick-up NameLCX-4R MD recorder Audio playing system MiniDisc digital audio system Laser diode properties Material: GaAlAs MQW Wavelength: = 790 nm Emission duration: c
2、ontinuous Laser output: less than 44.6 W (This output is the value measured at a distance of 200 mm from the lens surface on the optical pick-up block with 7 mm aperture.) Recording and playback time When using MDW-80 Maximum 160 min. in monaural Maximum 320 min. in stereo Revolutions 350 rpm to 2,8
3、00 rpm (CLV) Error correction ACIRC (Advanced Cross Interleave Reed Solomon Code) Sampling frequency 44.1 kHz Sampling rate converter Input: 32 kHz/44.1 kHz/48 kHz Coding ATRAC (Adaptive TRansform Acoustic Coding) ATRAC3-LP2 ATRAC3-LP4 SPECIFICATIONS Modulation system EFM (Eight to Fourteen Modulati
4、on) Number of channels 2 stereo channels 1 monaural channel Frequency response 20 to 20,000 Hz 3 dB Wow and Flutter Below measurable limit Inputs Microphone: stereo mini-jack, minimum input level 0.35 mV Line in: stereo mini-jack, minimum input level 49 mV Optical (Digital) in: optical (digital) min
5、i- jack Outputs i: stereo mini-jack, maximum output level 5 mW + 5 mW, load impedance 16 ohm Radio Frequency range AM: 531-1,602 kHz FM: 87.5-108.0 MHz General Power requirements Sony AC Power Adaptor (supplied*) connected at the DC IN 3 V jack: 230 V AC, 50/60 Hz (AEP, FR, CET model) 240 V AC, 50 H
6、z (Australian model) 230-240 V AC, 50 Hz (UK, HK model) 110/220 V AC, 60 Hz (Korean model) 100-240 V AC, 50/60 Hz (E, JE model) Nickel cadmium rechargeable battery NC-WMAA (supplied) LR6 (size AA) alkaline battery (not supplied) *) Except for Korean model Abbreviation FR: French model CET : East Eur
7、opean battery case assy qsbattery coil spring qdMAIN board qaRemove the solder. 4screws (M1.7x3) 5screws (M1.4x2) 1CN502 2arm 8CN501 9 MZ-G755 3-7. HOLDER ASSY 3Remove the holder assy to direction of the arrow B. 1Open the holder assy. A 2 B boss 3-6. OP SERVICE ASSY 4rack spring (s) 6thrust detent
8、spring 3precision pan screw (M1.4) 5precision pan screw (M1.4) 1washer (0.8 - 2.5) 2gear (SA) 8Pull off the lead screw. 7 B A 9Opening the over write head toward the direction A, remove the OP service assy toward the direction B. Note: Do not open the entire assy forcibly, when opening the over writ
9、e head. over write head section 10 MZ-G755 4two precision pan screws (M1.4) 5DC moter (sled) (M602) 3Remove four solders of motor flexible board. 1washer (0.8 - 2.5) 2gear (SA) 3-9. DC MOTOR (M602) 2Remove two solders of DC motor (over write head up/down) (M603). 1Remove four solders of DC motor (sl
10、ed) (M602). 3Remove four solders of DC motor (spindle) (M601). DC motor (sled) circular hole 5motor flexible board 4adhesive sheet Note: Align a circular hole in the stripping paper with a circular hole in the DC motor (sled), when mounting the motor flexible board. 3-8. MOTOR FLEXIBLE BOARD 11 MZ-G
11、755 1Remove six solders of motor flexible board. 4three precision pan screws (M1.4) qsDC moter (over write head up/down) (M603) 6two precision pan screws (M1.4) qagear chassis assy 0screw (M1.2 1.5) 9gear (HA) 8gear (HB) 7washer (0.8 - 2.5) 2washer (0.8 - 2.5) 3gear (HC) 5DC moter (spindle) (M601) D
12、C motor (over write head up/down) (M603) gear chassis assy gear (HA) 2.65 mm Note: Press-fit the gear (HA) up to the position of the DC motor (over write head up/down) (M603) as shown below. 3-10. DC MOTOR (M601), DC MOTOR (M603) 12 MZ-G755 2 In the normal mode, turn on the HOLD switch. While press-
13、 ing the VOL - key press the following order: tt.t.tt .t t.tXtX SECTION 4 TEST MODE 4-3. Operation in Setting the Test Mode When the test mode becomes active, first the display check mode is selected. Other mode can be selected from the display check mode. When the test mode is set, the LCD repeats
14、the following dis- play. When theXkey is pressed and hold down, the display at that time is held so that display can be checked. Caution: On the set having the microcomputer version 1.000, some adjusted values were set in the manual mode at the shipment, but these data will be cleared when the NV is
15、 reset. Therefore, on the set having the micro- computer version 1.000, change the adjusted values following the Change of Adjusted Values immediately after the NV was reset (see page 18). 4-4. Releasing the Test Mode For test mode set with the method 1: Turn off the power and open the solder bridge
16、 on SL801 (TEST) on the MAIN board. Note: Remove the solders completely. Remaining could be shorted with the chassis, etc. For test mode set with the method 2: Turn off the power. Note: If electrical adjustment (see page 18) has not been finished completely, always start in the test mode. (The set c
17、annot start in normal mode) 4-1. Outline This set provides the Overall adjustment mode that allows CD (PB) and MO (REC/PB) disk to be automatically adjusted when in the test mode. In this overall adjustment mode, the disc is discriminate between CD and MO, and each adjustment is automatically execut
18、ed in order. If a fault is found, the system displays its location. Also, the manual mode allows each individual adjustment to be automatically adjusted. Operation in the test mode is performed with the set. A key having no particular description in the text, indicates a set key. For the LCD display
19、, the LCD on the set is shown. 4-2. Setting Method of Test Mode There are two different methods to set the test mode: 1 Short SL801 (TEST) on the MAIN board with a solder bridge (connect pin 3 of IC801 to the ground). Then, turn on the power. MAIN BOARD (SIDE B) C821 C815 X801 SL801 (TEST) C809 R817
20、 C807C808R806 C814 FB801 AP817 AP828 BASS All lit This set LCD display SYNCMONOLP24REC RECDATEREMAIN 1 SHUFF PGM AM PM F e88:88 00 5 All off Microcomputer version display Ver 1.300 13 MZ-G755 4-5. Configuration of Test Mode 4-6. Manual Mode Mode to adjust or check the operation of the set by functio
21、n. Normally, the adjustment in this mode is not executed. However, the Manual mode is used to clear the memory, power supply adjustment, and laser power check before performing automatic adjustments in the Overall Adjustment mode. Transition method in manual mode 1.Setting the test mode (see page 12
22、). 2.Press the or VOL + key activates the manual mode where the LCD display as shown below. 3.During each test, the optical pick-up moves outward or in- ward while theNor.key is pressed for several sec- onds respectively. 4.Each test item is assigned with a 3-digit item number; 100th place is a majo
23、r item, 10th place is a medium item, and unit place is a minor item. The values adjusted in the test mode are written to the nonvolatile memory (for the items where adjustment was made). Press the or VOL + key. Press the x key. Press the x key. Press the x key. Press the x key. Press the N or REC ke
24、y. The key check quits, or open the upper panel. Press the T MARK or ENTER key for several seconds (about 3 seconds). ENTER key Test Mode (Display Check Mode) Servo Adjustment Manual Mode Key Check Mode Audio Adjustment Power Supply Adjustment OP Alignment Adjustment Press the . or VOL key. Electric
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SONY MZ-G755 维修电路图 MZ G755 维修 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf