Hafler SE120 Power Amplifier Service Manual 电路图.pdf
《Hafler SE120 Power Amplifier Service Manual 电路图.pdf》由会员分享,可在线阅读,更多相关《Hafler SE120 Power Amplifier Service Manual 电路图.pdf(13页珍藏版)》请在收音机爱好者资料库上搜索。
1、THE Hafler SE120 POWER AMPLIFIER SERVICE MANUAL HAFLER A DIVISION OF ROCKFORD CORPORATlON 613 SOUTH ROCKFORD DRIVE TEMPE, ARIZONA 85281 Downloaded from www.M manuals search engine RadioFans.CN 收音机爱 好者资料库 SPECIFICATIONS POWER RATING: Less than 0.006% total harmonic distortion at any power level up to
2、 60 watts continuous average power per channel into 8 ohms at any frequency between 20 Hz and 20 kHz with both channels driven. IM DISTORTION (IHF): Less than 0.005% from 1 to 60 watts, each channel, into 8 ohms. TYPICAL THD AT 60 WATTS INTO 8 OHMS: 20 Hz: 0.002% 1 kHz: 0.002% 20 kHz: 0.006% FREQUEN
3、CY RESPONSE INTO 8 OHMS: -3dB, 4Hz to 2OOkHz at 1 watt. +OdB, -0.5dB, 1OHz to 4OkHz at 60 watts. TYPICAL CHANNEL SEPARATION: 2OHz: 75dB 1kHz: 85 dB 20kHz: 65dB SIGNAL TO NOISE RATIO, UNWEIGHTED: Exceeds 1OOdB referred to 60 watts into 8 ohms. INPUT IMPEDANCE: 22,000 ohms INPUT SENSITIVITY: 1.1 volts
4、 rms for 60 watts into 8 ohms. DAMPING FACTOR: 100to1kHzinto8ohms,50to1OkHzinto8ohms. POWER CONSUMPTION: 60 watts both channels into 8 ohms: 300 VA Quiescent: 60 VA SIZE: 3-1/4” high plus 1/2” feet, 17” wide, 9” deep. (83 mm high plus 152 mm, 432 mm wide, 229 mm deep.) NET WEIGHT: 18 lbs. (8.2 kg) S
5、HIPPING WEIGHT: 20 lbs. (9.1 kg) Stereo/Mono Channel Operation: The SE120 delivers 60 watts continuous average power per channel into 8 ohms. It can be bridged for single channel operation producing up to 120 watts of power into 16 ohms. Input Mode Selector: This switch will allow the user to specif
6、y the input signal to the amplifier. A. Stereo Mode: This allows the right and left channels to reach their designated amplifier channels. This mode will deliver more than 60 watts into an 8 ohm load. B. Mono Mode: The SE1 20 can be operated in a bridged mode which drives both channels with the same
7、 signal and combines to deliver more than 150 watts into 8 ohms. This disables the right channel input and routes the signal through the left channel. Construction: The simplified construction of the SE120 improves relia- bility and results in consistent performance. The heavy duty case construction
8、 on the SE120 will provide years of durability and trouble free protection. Gold Plated RCA Input Connectors: This provides the most accurate signal transmission and lowest possible loss. Gold-plated terminals are immune to signal deterioration with time that can be caused by corro- sion in the conn
9、ectors. Speaker Output and Power Connectors: For minimum loss power transfer, high definition and oxidization resistance. Protection System: The SE120 is equipped with a unique protection system that constantly monitors the temperature of the output devices and takes corrective action to prevent dam
10、age to the amplifier as a result of excessive overheating. ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. Copyright 1990. All rights reserved -l- Downloaded from www.M manuals search engine RadioFans.CN 收音机爱 好者资料库 Downloaded from www.M manuals search engine RadioFans.CN 收音机爱 好者资料库 LINE CONNECT
11、IONS AND SWITCHING The SE120 is normally wired for use on 12OV AC power lines, as in the U.S.A. If your line voltage is different, you will need the special Hafler export power transformer which accommodates many other line voltages. Be sure your amplifier is wired for your line voltage before you p
12、lug it in. The SEl2Os power switch may be left on, and the amplifier switched remotely by connecting its line cord to the preamplifier (or other control center) which provides a switched AC outlet. Make sure that the control device can supply a current of 5 amperes to the SE 120, in addition to the
13、current required by any other switched units. You may instead connect the amplifier directly to a wall outlet, and control it with its own front panel power switch. CONNECTING CABLES GROUNDING: INPUT: Conventional shielded cables, often supplied with pre- amplifiers, may connect the control center t
14、o the amplifiers input jacks. Be sure the cables are not frayed or loosely connected to the plugs, and that the plugs outer shield connection is tight on the jack, to avoid hum. If you wish to install the SE120 more than a few feet from the preampli- fier, the permissible cable length to avoid loss
15、of high frequencies is determined by the preamplifiers output im- pedance and the internal capacitance of the cable. If the output impedance is 600 ohms or less, as with Hafler preamplifiers, and the cable capacitance is less than 50 picofarads per foot, up to 50- feet is acceptable. Ordinary stereo
16、 interconnecting cables often have higher capaci- tance, however, so a good quality low capacitance shielded wire should be used. When making long runs, keep the left and right cables close together, and avoid running them parallel to power wiring to reduce the likelihood of hum pickup. OUTPUT: The
17、wires which connect the speakers to the amplifier should be of sufficient size to preserve the SEl2Os high damping factor. Standard #18 gauge lamp cord is satisfac- tory for up to 15 feet if your speakers are of 8 ohms or higher impedance. A heavier gauge (#16 or larger) wire should be used with 4 o
18、hm speakers or 8 ohm speakers at a greater distance. Special loudspeaker cables which have adequate thickness to accommodate long runs are usually available from audio dealers. The SEl2Os red and black outputs accept standard banana plug connectors, including the double ones with 3/4” spacing. These
19、 are the most conven- ient to use if you will be disconnecting the speakers occa- sionally. The terminals will also clamp a spade lug, or a bare wire through the hole in the center post. Be sure there are no frayed wire ends which could touch adjacent terminals or the chassis. Tin bare wire ends wit
20、h solder to secure all strands. PHASING: Consistent phase relationships are important when con- necting speakers in order to enable full bass reproduction as well as midrange and high frequency time alignment. To be sure all speakers in a system are wired in phase to the amplifier, each ground or -
21、speaker terminal should be connected to its black ground tenninal on the SE 120 and the speakers + terminal to the corresponding red binding post. Speaker connecting cable identifies one wire from the other by the color of the wire, or by marking or coloring the insulation. NOTE: In the special case
22、 of monophonic operation of the SE 120, (described later) different speaker connections are employed. The black output terminals of the SE120 are connected together internally and grounded to the chassis. This facilitates the use of external devices which use a common ground connection, such as some
23、 headphone junctionboxes. You must be sure that the ground or shield connection from such a device goes to a black terminal on the SE1 20. NOTE: No such connection may be made when the SE120 is connected for bridged mono operation. CONVENTIONAL STEREO CONNECTIONS It is best to make all connections w
24、ith the SE120 switched off. Each of the stereo speakers connects to one horizontal pair of red and black outputs, as identified left or right on back of the SE 120. The input signals connect to the corresponding input jacks, and the mono/stereo switch should be set to stereo. CONNECTIONS FOR MONOPHO
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Hafler SE120 Power Amplifier Service Manual 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


