pioneer CDJ-200_RRV3095 电路图.pdf
《pioneer CDJ-200_RRV3095 电路图.pdf》由会员分享,可在线阅读,更多相关《pioneer CDJ-200_RRV3095 电路图.pdf(80页珍藏版)》请在收音机爱好者资料库上搜索。
1、 ORDER NO. PIONEER CORPORATION 4-1, Meguro 1-chome, Meguro-ku, Tokyo 153-8654, Japan PIONEER ELECTRONICS (USA) INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A. PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, Belgium PIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra Road, #04-01
2、, Singapore 159936 PIONEER CORPORATION 2005 CDJ-200 RRV3095 COMPACT DISC PLAYER CDJ-200 THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S). ModelTypePower RequirementRemarks CDJ-200KUCXJAC120V CDJ-200RLTXJAC110-120V/AC220-240V CDJ-200WYXJAC220-240V CDJ-200RFXJAC110-120V/AC220-240V NECES
3、SARY INFORMATION FOR DHHS RULES MARKED ON THE TOP COVER BELOW: CAUTION LASER RADIATION WHEN OPEN. DO NOT STARE INTO BEAM For details, refer to Important Check Points for good servicing. T-IZY MAR. 2005 printed in Japan RadioFans.CN 收音机爱 好者资料库 CDJ-200 2 1234 1234 C D F A B E SAFETY INFORMATION 1. SAF
4、ETY PRECAUTIONS The following check should be performed for the continued protection of the customer and service technician. LEAKAGE CURRENT CHECK Measure leakage current to a known earth ground (water pipe, conduit, etc.) by connecting a leakage current tester such as Simpson Model 229-2 or equival
5、ent between the earth ground and all exposed metal parts of the appliance (input/output terminals, screwheads, metal overlays, control shaft, etc.). Plug the AC line cord of the appliance directly into a 120V AC 60 Hz outlet and turn the AC power switch on. Any current measured must not exceed 0.5 m
6、A. ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED BEFORE RETURNING THE APPLIANCE TO THE CUSTOMER. 2. PRODUCT SAFETY NOTICE Many electrical and mechanical parts in the appliance have special safety related characteristics. These
7、are often not evident from visual inspection nor the protection afforded by them necessarily can be obtained by using replacement components rated for voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in this Service Manual. Electrical components
8、 having such features are identified by marking with a on the schematics and on the parts list in this Service Manual. The use of a substitute replacement component which does not have the same safety characteristics as the PIONEER recommended replacement one, shown in the parts list in this Service
9、 Manual, may create shock, fire, or other hazards. Product Safety is continuously under review and new instructions are issued from time to time. For the latest information, always consult the current PIONEER Service Manual. A subscription to, or additional copies of, PIONEER Service Manual may be o
10、btained at a nominal charge from PIONEER. Leakage current tester Reading should not be above 0.5 mA Device under test Test all exposed metal surfaces Also test with plug reversed (Using AC adapter plug as required) Earth ground AC Leakage Test (FOR USA MODEL ONLY) WARNING This product contains lead
11、in solder and certain electrical parts contain chemicals which are known to the state of California to cause cancer, birth defects or other reproductive harm. Health it is not meant for the casual do-it- yourselfer. Qualified technicians have the necessary test equipment and tools, and have been tra
12、ined to properly and safely repair complex products such as those covered by this manual. Improperly performed repairs can adversely affect the safety and reliability of the product and may void the warranty. If you are not qualified to perform the repair of this product properly and safely, you sho
13、uld not risk trying to do so and refer the repair to a qualified service technician. RadioFans.CN 收音机爱 好者资料库 CDJ-200 3 5678 56 7 8 C D F A B E WARNING ! THE AEL (ACCESSIBLE EMISSION LEVEL) OF THE LASER POWER OUTPUT IS LESS THAN CLASS 1 BUT THE LASER COMPONENT IS CAPABLE OF EMITTING RADIATION EXCEEDI
14、NG THE LIMIT FOR CLASS 1. A SPECIALLY INSTRUCTED PERSON SHOULD DO SERVICING OPERATION OF THE APPARATUS. LASER DIODE CHARACTERISTICS MAXIMUM OUTPUT POWER : 5 mW WAVELENGTH : 780 785 nm Additional Laser Caution : See page 51. 1. Laser Interlock Mechanism The position of the switch (S1901) for detectin
15、g loading completion is detected by the system microprocessor, and the design prevents laser diode oscillation when the switch is not in LPS1 terminal side (when the mechanism is not clamped and LPS1 signal is high level.) Thus, the interlock will no longer function if the switch is deliberately set
16、 to LPS1 terminal side. ( if LPS1 signal is low level ). In the test mode the interlock mechanism will not function. Laser diode oscillation will continue, if pin 41 of TC94A15FG (IC105) on the MAIN Assy is connected to GND, or else the terminals of Q105 are shorted to each other (fault condition).