Sony Ta-Ax44 Stereo Amplifier 电路图.pdf
《Sony Ta-Ax44 Stereo Amplifier 电路图.pdf》由会员分享,可在线阅读,更多相关《Sony Ta-Ax44 Stereo Amplifier 电路图.pdf(36页珍藏版)》请在收音机爱好者资料库上搜索。
1、GENERAL System: Power Requirements: Power Consumption: AC Outlets: Dimensions: US Model Canadian Model AEP Model UK Model E Model INTEGRATED STEREO AMPLIFIER SPECIFICATIONS Preamplifier section: low-noise IC equalizer amp.; ASP tone control Power amplifier section: pure- complementary SEPP OCL power
2、 amplifier with all stages direct coupled US, Canadian model: 120 V ac, 60 Hz AEP model: 220 V ac (240 V ac adjustable by authorized Sony personnel), 50/60 Hz UK model: 240 V ac (220 V ac adjustable by authorized Sony personnel), 50/60 Hz E model: 120, 220 or 240 V ac adjustable, 50160 Hz US, AEP mo
3、del: 100 watts Canadian model: 155 watts UK model: 270 watts E model: 100 watts AEP, UK model: 3 switched, total 100 watts max. US, Canadian model: Two switched (total 100 watts) One unswitched (100 watts) E model: 2 switched, total 100 watts max. 1 unswitched, 100 watts max. Approx. 430 x 80 x 290
4、mm (w/h/d) (I 7 x 31/ x 11 I/ inches) including projecting parts and controls Weight:Approx. 5.6 kg (12 Ibs 6 oz) net Approx. 6 kg (13 lbs 4 oz) in shipping carton AMPLIFIER SECTION POWER OUTPUT AND TOTAL HARMONIC DISTORTION : (US, Canadian model) With 8 ohm loads, both channels driven, from 20 - 20
5、,000 Hz; rated 40 watts per chan- nel minimum RMS power, with no more than 0.008% total harmonic distortion from 250 milliwatts to rated output. - Continued on page 2 - SAFETY-RELATED COMPONENT WARNING! COMPONENTS IDENTIFIED BY SHADING AND MARK B ON THE SCHEMATIC DIAGRAMS, EXPLODED VIEWS AND IN THE
6、PARTS LIST ARE CRITICAL TO SAFE OPERATION.REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR ATTENTION AU COMPOSANT AYANT RAPPORT AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS d. LA ScCURITti!PUBLISHED BY SONY. LES COMPOSANTS IDENTIFIES PAR UNE TRAME ET U N E M A R Q U E A SUR LES DIAGRA
7、MMES SCHi- MATIQUES, LES VUES CCLATiES ET LA LISTE DES PIiCES SONT CRITIQUES POUR LA SliCURITi DE FONCTIONNEMENT. NE REMPLACER CES COMPO- S O N Y SANTS QUE PAR DES PICCES SONY DONT LES NU- MCROS SONT DONNES DANS CE MANUEL OU DANS LES SUPPLeMENTS PUBLItiS PAR SONY.SERVICE MANUAL RadioFans.CN 收音机爱 好者资
8、料库 Continuous RMS Power Output (Lea than 0.688% THD, both channels driven simultaneous- ly) (AEP, UK, E model): Power Bandwidth (IHF): Dynamic Headroom: Harmonic Distortion: Intermodulation (IM) Distortion (60Hr: 7kHz=4: 1): Frequency Response: Residual Noise: Damping Factor: At 20 Hz- 20 kHz 40 + 4
9、0 watts (8 ohms) At 1 kHz 44 + 44 watts (8 ohms) According to DIN 45500 40 + 40 watts (8 ohms) 5 Hz - 45 kHz 1.8 dB (78 IHF) Less than 0.008% at rated output Less than 0.008% at rated output PHONO: AIAA equalization curve f0.5dB TUNER DAD/AUX TAPE 1.2 10Hz-120kHz;OdB Less than 35pV (8 ohms, network
10、A) 50 (8 ohms, 1 kHz) Inputs: I Maximum inputSIN (weihfmg capability (1 kliz)network, (“put le”e, I1 * 70 IHF outputs:RECOUT1,2 Voltage 150 mV Impedance 4.7 k ohms SPEAKER A, B Accepts speakers of 8 - 16 ohms. HEADPHONES Accepts low and high impedance head- phones. Tone Controls:BASS +lOdB at 100 Hz
11、 (turnover freq. 500 Hz) TREBLE ?lOdB at 10 kHz (turnover freq. 2 kHz) Subsonic Filter:6 dB/octave attenuation below 15 Hz High Filter:6 dB/octave attenuation above 9 kHz Muting:-20dB 1 OdB=0.775V 1 FEATURES The TA-AX44 integrated stereo amplifier incorporates a number of technical breakthroughs in
12、circuit design. On its attractive front panel most of the controls and switches are “touch pad” switches and the tone, filter and volume settings are shown by fluorescent displays. HIGHLIGHTS OF THE TA-AX44S CIRCUIT ASP (Audio Signal Processor) IC in the preamplifier stage Sony has developed a new a
13、udio device, called the Audio Signal Processor IC, which can digitally control the tone, filter and volume settings. The ASP IC also permits electronic program source selec tion. Mechanical controls and switches have been practically eliminated from the front panel. In combination with a microcom- p
14、uter and a non-volatile memory IC, the ASP IC offers greater flex- ibility - an Acoustic Function, an ability to store and recall two sets of tonal adjustments. Legato linear power amplifier stage The operation of the power amplifier stage is stable without any observable distortion up through the h
15、igher frequencies. We call this power amp “Legato Linear” because its switching distortion is very low and its output waveform smooth. Simple, straight signal path layout A heat-pipe cooling system and the ASP IC layout near the input and output terminals minimize wiring losses and allow low distor-
16、 tion ooeration. OPERATING VOLTAGE Before connecting the unit to the power source, check that the operating voltage of your unit is the same as the local power line voltage. The Continental European model (AEP model) operates on 220 V ac (or 240 V ac adjustable by authorized Sony personnel). The Uni
17、ted Kingdom model (UK model) operates on 240 V ac (or 220 V ac adjustable by authorized Sony personnel). The model for other countries (E model) operates on either 120, 220 or 240 V ac. The voltage selector is located on the rear panel. If the selector must be reset, disconnect the ac power cord and
18、 turn the selector with a coin so that the arrow mark of the selector points to the proper voltage figure. The US, Canadian model operates on 120 V ac. Wireless remote control operation Using the optional RM-44 system remote controller, various opera. tions - power on/off, program selection, acousti
19、c setting selec- tion, muting on/off and volume adjustment - can be remotely con- trolled. RadioFans.CN 收音机爱 好者资料库 PRECAUTIONS On safety ? Check that the operating voltage of your unit is identical with the voltage of your local power supply. ? Should any liquid or solid object fall into the cabinet
20、, unplug the unit and have it checked by qualified personnel before operating It any further. ? Unplug the unit from the wall outlet if it is not to be used for an extended period of time. To disconnect the cord, pull it out by grasping the plug. Never pull the cord itself. On installation ? Do not
21、install the unit in a location near heat sources such as radiators or air ducts, or in a place subject to direct sunlight, ex- cessive dust, mechanical vibration or shock. ? Good air circulation is essential to prevent internal heat build-up in the unit. Place the unit in the location with adequate
22、air circula- tion. Do not place the unit on a soft surface, such as a rug that would block the ventilation holes on the bottom. ? DO not place anything on top of the cabinet. The top ventilation holes must be unobstructed for the proper operation of the unit and to prolong the life of its components
23、. On operation ? Before making program source connections, be sure to turn the power switch off and unplug the unit. ? Do not attempt to test the protection circuits by blocking the ven- tilation holes or connecting improper loads. ? When the unit is not used, turn the power off, to conserve energy
24、and to extend the useful life of your unit. On cleaning the cabinet Clean the cabinet, panel and controls with a soft cloth lightly moistened with mild detergent solution. Do not use any type of abrasive pad, scouring powder or solvent such as alcohol or ben- zine. On repacking Do not throw away the
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Sony Ta-Ax44 Stereo Amplifier 电路图 Ta Ax44
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf