1、ALIGNMENT PROCEDURE OF 18WS2 REVISION: 00 ENG-18WS2-08 Page: 1 OF 6 Print date: 06-4-10 ALIGNMENT PROCEDURE MODEL: 18WX ST II REVISION: 00 DATE : AUGUST 09, 2000 PREPARED BY:_ CHECKED BY: _ APPROVED BY: _ TOTAL PAGES: Downloaded from www.cbradio.nl ALIGNMENT PROCEDURE OF 18WS2 REVISION: 00 ENG-18WS2
2、-08 Page: 2 OF 6 Print date: 06-4-10 18WS2 ALIGNMENT INSTRUCTION 1.0 TEST CONDITION: 1.1. STANDARD DC POWER: EXT.DC 13.8VDC 1.2. MEASUREMENT CHANNEL: CB CH19 (27.185MHz) WX CH3 (162.475MHz) 1.3. STANDARD AUDIO LOADING: CB/WX 8 1.4. ANTENNA IMPEDANCE: CB/WX 50 1.5. STANDARD REF. MODULATION: CB 30% (A
3、M) WX 3KHz (FM) 1.6. STANDARD REF. AUDIO OUTPUT: CB/WX 0.5W 1.7. FREQUENCY TABLE CB BAND WX BAND CH NO. FREQ. (MHz) CH NO. FREQ. (MHz) 01 26.965 1 162.550 02 26.975 2 162.400 03 26.985 3 162.475 04 27.005 4 162.425 05 27.015 5 162.450 06 27.025 6 162.500 07 27.035 7 162.525 08 27.055 8 161.650 09 27
4、.065 9 161.775 10 27.075 10 163.275 11 27.085 12 27.105 13 27.115 14 27.125 15 27.135 16 27.155 17 27.165 18 27.175 19 27.185 20 27.205 21 27.215 22 27.225 23 27.255 24 27.235 25 27.245 26 27.265 27 27.275 28 27.285 29 27.295 30 27.305 31 27.315 32 27.325 33 27.335 34 27.345 35 27.355 36 27.365 37 2
5、7.375 38 27.385 39 27.395 40 27.405 ALIGNMENT PROCEDURE OF 18WS2 REVISION: 00 ENG-18WS2-08 Page: 3 OF 6 Print date: 06-4-10 1.8. TEST EQUIPMENT SETUP AS BELOW: A. TX test equipment setup: Spectrum Power Analyzer Supply Modulation Wattmeter 18WS2 Meter D.U.T. Oscilloscope Frequency Audio Gen. Counter
6、 Distortion AC Meter Voltmeter B. RX test equipment setup: SINAD Meter RF Signal Power Generator Supply Distortion 8 ohm 18WS2 Meter loading D.U.T. Oscilloscope Note: D.U.T. = device under test ALIGNMENT PROCEDURE OF 18WS2 REVISION: 00 ENG-18WS2-08 Page: 4 OF 6 Print date: 06-4-10 2.0 ALIGNMENT 2.1
7、LOCAL FREQ. ALIGNMENT TEST ITEM TEST CONDITION & PROCEDURE PURPOSE 1. VCO Frequency Connect a 5pf capacitor to TP7. Set CB mode RX CH19. Adjust VC1 FOR 16.485 MHz at the frequency counter. 2. 10.245MHz frequency Connect a 5pf capacitor to TP8. Set CB mode RX CH19. Adjust VC2 FOR 10.245 MHz at the fr
8、equency counter. 2.2 VCO ALIGNMENT TEST ITEM TEST CONDITION & PROCEDURE PURPOSE 1. CB VCO Voltage 1. Connect a digital multi-meter to TP1 2. Set CB RX mode: CH1. Adjust L11 for 1.0 0.1 V. 3. Set CB TX mode Check CH40 4.5V. 2. WX VCO Voltage 1. Connect a digital multi-meter to TP1 2. Set WX mode CH08
9、. Adjust L1 FOR 1.5 0.1V. Check CH1 0 3.0V. 2.3 WX RECEIVER TEST ITEM TEST CONDITION & PROCEDURE PURPOSE 1. Audio output level 1. Set WX mode, CH3. 2. Output of signal generator thru a 0.01F to TP3. 3. RF Gen. set 10.7MHz, Fmod= 1KHz, Dev.= 3KHz, RF level: 1mV. 4.Set volume control to middle positio
10、n. 1. Adjust L9 for maximum audio output & minimum distortion at the distortion meter.(Distortion less than 8% ) 2. Set volume control to maximum position, audio power output shall be more than 3 Watts. 2. WX sensitivity 1.Output of signal generator to antenna input terminal. 2. RF Gen. set 162.475M
11、Hz, Fmod= 1KHz, Dev.= 3KHz, RF level: 1V. 3. WX set CH3. 1. Adjust L4 and L3 for more than 12dB at the SINAD meter. 2. Repeat as needed. Check all channels sens. must met D.T.S. ALIGNMENT PROCEDURE OF 18WS2 REVISION: 00 ENG-18WS2-08 Page: 5 OF 6 Print date: 06-4-10 2.4 CB Receiver Alignment TEST ITE
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Service_Manual_Cobra_18WX_STII_EMG
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf