Icom_AT-180_user.pdf
《Icom_AT-180_user.pdf》由会员分享,可在线阅读,更多相关《Icom_AT-180_user.pdf(9页珍藏版)》请在收音机爱好者资料库上搜索。
1、 2006 Icom America Inc. Icom America, Inc. 2380 116th Ave NE Bellevue, WA 98004 425.454.7619 AT-180 Automatic Antenna Tuner Operating Instructions and Service Information Compiled from the IC-706 Operating Instructions and Service Manual 27 4RECEIVE AND TRANSMIT The AT-180 automatic antenna tuner ma
2、tches the IC- 706MKIIG to the connected antenna automatically. Once the tuner matches an antenna, the variable capacitor angles are memorized as a preset point for each frequency range (100 kHz steps). Therefore, when you change the frequency range, the variable capacitors are automatically preset t
3、o the memorized point. N No ot te e: : The AT-180 cannot be used for the 144/430 MHz band. When operating on the 144/430 MHz band, push- ing the tuner switch selects the call channel (p. 39). The AT-180 can match both HF and 50 MHz bands. However, operation is different for the HF and 50 MHz bands.
4、T TU UN NE ER R O OP PE ER RA AT TI IO ON N F Fo or r t th he e H HF F b ba an nd d: : Push TUNER to turn the tuner ON. The antenna is tuned automatically during transmission when the antenna SWR is higher than 1.5:1. When the tuner is OFF, the TUNER light goes out. F Fo or r t th he e 5 50 0 MMH Hz
5、 z b ba an nd d: : Push and hold TUNER to tune the antenna. If the TUNER light fl ashes slowly while transmitting, push and hold TUNER again to re-tune the antenna. MMA AN NU UA AL L T TU UN NI IN NG G During SSB operation on HF bands at low voice lev- els, the AT-180 may not be tuned correctly. In
6、such cases, manual tuning is helpful. Push and hold TUNER for 1 sec. to start manual tun- ing. CW mode is selected, a side tone is emitted, and the TUNER light fl ashes; then, the previous mode is select- ed. If the tuner cannot reduce the SWR to less than 1.5:1 after 20 sec. of tuning, the TUNER li
7、ght goes out. In this case, check the following: the antenna connection and feedline the antenna SWR (p. 26; meter function) T Th hr ro ou ug gh h i in nh hi ib bi it t (HF bands only) The AT-180 has a through inhibit condition. When selecting this condition, the tuner can be used at poor SWRs. In t
8、his case, automatic tuning in the HF bands activates only when exceeding SWR 3:1. Therefore, manual tuning is necessary each time you change the frequency. Although termed “through inhibit,” the tuner will be “through” if the SWR is high- er than 3:1 after tuning. T Tu un ne er r s se en ns si it ti
9、 iv ve e c co on nd di it ti io on n (HF bands only) If you require critical tuning at any time during trans- mission, select the tuner sensitive condition. See p. 55 for selection. A Au ut to omma at ti ic c t tu un ne er r s st ta ar rt t (HF bands only) If you want to turn OFF the tuner under con