Icom_IC-2KL_adjust.pdf
《Icom_IC-2KL_adjust.pdf》由会员分享,可在线阅读,更多相关《Icom_IC-2KL_adjust.pdf(1页珍藏版)》请在收音机爱好者资料库上搜索。
1、 ICOM IC-2KL ADJUSTMENT PROCEDURE IC-2KL INSTRUMENT TEST ADJUSTMENT CONDITIONS REQUIRED UNIT POINT UNIT PARTS HOW TO ADJUST READING INITIAL Connect IC-2KL to the RIF exciter MAIN R44 MAXIMUM CLOCKWISE SETUP (RF INPUT, ALC, PTT, ACC, etc). MAIN R36 MAXIMUM CLOCK WISE Connect IC-2KL output to a MAIN R
2、18 TURN R18 AND ADJUST STARTING dummy load. Connect IC-2KL to FROM MAXIMUM COUNTER- the power supply IC-2KLPS. CLOCKWISE IDLE Lift center tap lead from L4 and Ammeter (1 A) Power F1 PA1 R9 PA1 ADJUST R9 (ON PA-1) FOR 200 ma CURRENT insert an ammeter. supply regulator PA2 R9 PA2 REPEAT ABOVE FOR PA-2
3、 unit Vc METER Meter switch: Vc Multimeter Vc meter MAIN R40 ADJUST R40 TO INDICATE THE SAME Connect multimeter to fuse (F1) VOLTAGE AS SHOWN ON THE MULTIMETER PROTECTION Meter switch: PRO Dummy Load PRO R1 ADJUST ALC ADJUSTMENT POT (R1) CENTER OF PRO CIRCUIT Set mode to RTTY and transmit meter FOR