IC-7610_remote_control_user.pdf
《IC-7610_remote_control_user.pdf》由会员分享,可在线阅读,更多相关《IC-7610_remote_control_user.pdf(17页珍藏版)》请在收音机爱好者资料库上搜索。
1、CI-V REFERENCE GUIDE i7610 HF/50MHz TRANSCEIVER Table of contents 1 1 Remote control 2 Remote control (CI-V) information 2 D CI-V connection 2 D Preparing 2 D About the data format 2 D Command table 3 D Command formats 10 Remote control 2 Connection example DCI-V connection The transceivers operatin
2、g frequency, mode, VFO and memory selection, can be remotely controlled using a PC. Use a USB cable (A-B type, user supplied) to connect the IC-7610 and the PC (controller). The required USB driver and driver installation guide can be downloaded from the Icom web site. Go to “http:/www.icom.co.jp/wo
3、rld,” and then click “Support,” “Firmware Updates / Software downloads” in sequence. L The download procedure on the web page may be changed without notice. DPreparing The Icom Communications Interface V (CI-V) is used for remote control. To control the transceiver, fjrst set its address, data commu
4、nication speed, and transceive function. These settings are set in Set mode (Refer to the IC-7610 instruction manual). DAbout the data format The CI-V system can be written using the following data formats. Data formats differ according to command numbers. A data area or sub command is added for som
5、e commands. Controller to IC-7610 IC-7610 to controller FE FE98E0CnScData areaFD Preamble code (fixed) Transceivers default address Controllers default address Command number (see the command table) Sub command number (see the command table) BCD code data for frequency or memory number entry End of
6、message code (fixed) FE FEE098FBFD FE FEE098FAFD Preamble code (fixed) Controllers default address Transceivers default address OK code (fixed) End of message code (fixed) NG code (fixed) qwertyu FE FEE098CnScData areaFD qwertyu OK message to controller NG message to controller Remote control (CI-V)
7、 information L Make the connection as short as possible. The transceiver may not be recognized by the controller, depending on the USB cable length. PC Type A Type B To a USB port To the USB 1 port A/B USB cable (user supplied) Cmd. Sub cmd.DataDescription 00see p. 10Send frequency data (transceive)
8、 01see p. 10Send mode data (transceive) 02see p. 10Read band edge frequencies 03see p. 10Read operating frequency 04see p. 10Read operating mode 05see p. 10Set operating frequency 06see p. 10Set operating mode 07Select the VFO mode B0Exchange main and sub bands B1Equalize main and sub bands C0Turn O
9、FF Dualwatch C1Turn ON Dualwatch C2*00 or 01Send/read the dualwatch setting (00=OFF, 01=ON) D0Select the main band D1Select the sub band D2*00Send/read main band selection 01Send/read sub band selection 08Select the Memory mode 0001 to 0099 Select the Memory channel (0001=M-CH01, 0099=M-CH99) 0100Se
10、lect program scan edge channel P1 0101Select program scan edge channel P2 09Memory write 0AMemory copy to VFO 0BMemory clear 0E00Cancel the scan 01Start a Programmed/memory scan 02Start a Programmed scan 03Start a F scan 12Start a Fine programmed scan 13Start a Fine F scan 22Start a Memory scan 23St
11、art a Select memory scan Ax (x=1 to 7) Select F scan span ( x=1 (5 kHz), x=2 (10 kHz), x=3 (20 kHz), x=4 (50 kHz), x=5 (100 kHz), x=6 (500 kHz), x=7 (1 MHz) B0Clear the Select channel setting B1Set as select channel ( The previously set number by CI-V is set after turning power ON, or “1” is selecte
12、d if no selection is performed.) 01 to 03Set the channel as a Select channel (01=SEL1, 02=SEL2, 03=SEL3) B200 to 03Set the Select memory scan channel (00=ALL, 01=SEL1, 02=SEL2, 03=SEL3) D0Set Scan resume OFF D3Set Scan resume ON 0F00Read Split OFF setting 01Read Split ON setting 00Turn OFF the Split
13、 function 01Turn ON the Split function 10*00 to 08Send/read the tuning step ( 00=OFF (10 Hz or 1 Hz), 01=100 Hz, 02=1 kHz, 03=5 kHz, 04=9 kHz, 05=10 kHz, 06=12.5 kHz, 07=20 kHz, 08=25 kHz) 11*00Send/read attenuator OFF setting 03Send/read 3 dB attenuator setting 06Send/read 6 dB attenuator setting 0
14、9Send/read 9 dB attenuator setting 12Send/read 12 dB attenuator setting 15Send/read 15 dB attenuator setting 18Send/read 18 dB attenuator setting 21Send/read 21 dB attenuator setting 24Send/read 24 dB attenuator setting Cmd. Sub cmd.DataDescription 27Send/read 27 dB attenuator setting 30Send/read 30
15、 dB attenuator setting 33Send/read 33 dB attenuator setting 36Send/read 36 dB attenuator setting 39Send/read 39 dB attenuator setting 42Send/read 42 dB attenuator setting 45Send/read 45 dB attenuator setting 12*00*100 or 01Select/read ANT1 selection (00=RX ANT OFF, 01=RX ANT ON) 01*100 or 01Select/r
16、ead ANT2 selection (00=RX ANT OFF, 01=RX ANT ON) 1300Speech all data with voice synthesizer (S meter level, frequency and mode) 01Speech the operating frequency and S meter level by voice synthesizer 02Speech the operating mode by voice synthesizer L The mode is announced after the ongoing speech. 1
17、4*010000 0255 Send/read the AF level (0000=min. to 0255=max.) 020000 0255 Send/read the RF gain level (0000=min. to 0255=max.) 030000 0255 Send/read the squelch level (0000=min. to 0255=max.) 050000 0255 Send/read the APF level (10 Hz steps) ( 0000=Pitch550 Hz, 0128=Pitch, 0255=Pitch+550 Hz) 060000
18、0255 Send/read the NR level (0000=0%, 0255=100%) 070000 0255 Send/read inner TWIN PBT position ( 0000=max. CCW, 0128=center, 0255=max. CW) 080000 0255 Send/read outer TWIN PBT position ( 0000=max. Counter Clockwise, 0128=center, 0255=max. Clockwise) 090000 0255 Send/read CW pitch (5 Hz steps) ( 0000
19、=300 Hz, 0128=600 Hz, 0255=900 Hz) 0A0000 0255 Send/read RF power ( 0000=min. to 0255=max.) 0B0000 0255 Send/read MIC gain ( 0000=min. to 0255=max.) 0C0000 0255 Send/read keying speed (0000=6 wpm to 0255=48 wpm) 0D0000 0255 Send/read Nothc fjlter setting ( 0000=max. Counter Clockwise, 0128=center, 0
20、255=max. Clockwise) 0E0000 0255 Send/read the COMP level (0000=0 to 0255=10) 0F0000 0255 Send/read the Break-IN Delay setting (0000=2.0 d to 0255=13.0 d) 120000 0255 Send/read NB level (0000=0% to 0255=100%) 130000 0255 Send/read the DIGI-SEL shift amount ( 0000=min. to 0255=max.) 140000 0255 Send/r
21、ead DRIVE gain (0000=0% to 0255=100%) 150000 0255 Send/read Monitor audio MONI level (0000=0% to 0255=100%) 160000 0255 Send/read the VOX gain (0000=0% to 0255=100%) 170000 0255 Send/read the Anti VOX gain (0000=0% to 0255=100%) 190000 0255 Send/read LCD backlight brightness (0000=0% to 0255=100%) 1
22、50100 or 01Read noise or S-meter squelch status (00=Close, 01=Open) 020000 to 0255 Read S-meter level (0000=S0, 0120=S9, 0241=S9+60 dB) 0500 or 01Read various squelch (tone squelch, and so on) status (00=Close, 01=Open) DCommand table NOTE: Operation to the some control dials overrides CI-V commands
23、. If a control dial (such as the AF Volume dial that has a mark on it) is rotated after sending a CI-V command, the command will be overwritten by the operation. 11* Remote control 3 Cmd. Sub cmd.DataDescription 0700 or 01Read the Overfmow status ( 00=OVF indicator is OFF, 01=OVF indicator is ON) 11
24、0000 0255 Read the PO meter level (0000=0% to 0143=50% to 212=100%) 120000 0255 Read SWR meter level ( 0000=SWR1.0, 0048=SWR1.5, 0080=SWR2.0, 0120=SWR3.0) 130000 0255 Read ALC meter level (0000=Min. to 0120=Max.) 140000 0255 Read COMP meter level (0000=0 dB, 0130=15 dB, 0241=30 dB) 150000 0255 Read