1、9 1 PREPARATION BEFORE SERVICING I REQUIRED TEST EQUIPMENT AC outlet RF power meter (terminated type) Frequency counter RF voltmeter FM deviation meter Modulation analyzer Distortion meter Oscilloscope Audio generator Standard signal generator (SSG) Digital multimeter AC millivoltmeter DC voltmeter
2、DC ammeter Spectrum analyzer Attenuator External speaker Terminator EQUIPMENTGREDE AND RANGEEQUIPMENTGREDE AND RENGE Voltage: 85 V265 V Measuring range: 10200 W Frequency range: 1.8100 MHz Impedance: 50 SWR: Less than 1.2 : 1 Frequency range: 0.1100 MHz Frequency accuracy: 0.5 ppm or better Sensitiv
3、ity: 100 mV or better Frequency range: 0.1100 MHz Measuring range: 0.0110 V Frequency range: DC500 MHz Measuring range: 0 to 5 kHz Frequency range: At least 90 MHz Measuring range: 0100 % Frequency range: 1 kHz 10 % Measuring range: 1100 % Frequency range: DC20 MHz Measuring range: 0.0120 V Frequenc
4、y range: 3003000 Hz Measuring range: 1500 mV Frequency range: 0.1100 MHz Output level: 0.1 V32 mV (127 to 17 dBm) Imput impeadance: 10 M/DC or beter Measuring range: 10 mV10 V Input impedance:50 k/V DC or better Measurement capability: 1 A/30 A Frequency range: At least 90 MHz Spectraum bandwidth: 1
5、00 kHz or more Power attenuation: 50 or 60 dB Capacity: 150 W or more Input impedance: 8 Capacity: 5 W or more Resistance: 50 and 150 Capacity: 150 W or more IC-7800 ADJUSTMENT PROCEDURES 10 *This output level of a standard signal generator (SSG) is indicated as SSGs open circuit. 2 OSC UNIT ADJUSTM
6、ENTS REFERENCE OUTPUT REF IN OUTPUT REF OUT OUTPUT ADJUSTMENT ADJUSTMENTADJUSTMENT CONDITION MEASUREMENT VALUE POINT UNITLOCATIONUNITADJUST 1 2 3 Set the OSC unit to the external ref- erence mode on the set mode. MAIN display frequency : 10.000 MHz Connect an SSG to J71 on the OSC unit and set as: F
7、requency: 10.000 MHz Level: 71 mV* (10 dBm) Modulation: OFF Terminates J73 with 50 . Receiving MAIN display frequency : 10.000 MHz Receiving Terminates J72 with 50 . SUB display frequency : 10.000 MHz Receiving Set the OSC unit to the internal ref- erence mode on the set mode. MAIN display frequency
8、 : 10.000 MHz Receiving Terminates J73 with 50 . SUB display frequency : 10.000 MHz Receiving Terminates J72 with 50 . SUB display frequency : 10.000 MHz Receiving OSC OSC OSC Connect an RF volt- meter to the J72. Connect an RF volt- meter to the J72. Connect an RF volt- meter to the J73. Connect an
9、 RF volt- meter to the J71. Connect an RF volt- meter to the J72. Connect an RF volt- meter to the J73. Maximum voltage 0 dBm 3.0 dB 0 dBm 3.0 dB 10.0 dBm 3.0 dB 0 dBm 3.0 dB 0 dBm 3.0 dB OSCL61, L62 Verify Verify Verify Verify Verify 11 3 RX PLL-A UNIT ADJUSTMENTS 40M OUTPUT LPL LOCK VOLTAGE HPL LO
10、CK VOLTAGE (VCO1) (VCO2) (VCO3) (VCO4) (VCO5) (VCO6) (VCO1) (VCO2) (VCO3) (VCO4) (VCO5) ADJUSTMENT ADJUSTMENTADJUSTMENT CONDITION MEASUREMENT VALUE POINT UNITLOCATIONUNITADJUST 1 1 2 1 2 3 4 5 6 7 8 9 10 11 MAIN display frequency : 40.000 MHz Mode: USB Receiving MAIN display frequency : 0.030 MHz Mo
11、de: USB Receiving MAIN display frequency : 7.999 MHz Mode: USB Receiving MAIN display frequency : 7.999 MHz Mode: USB Receiving MAIN display frequency : 14.999 MHz Mode: USB Receiving MAIN display frequency : 21.999 MHz Mode: USB Receiving MAIN display frequency : 29.999 MHz Mode: USB Receiving MAIN
12、 display frequency : 44.999 MHz Mode: USB Receiving MAIN display frequency : 60.000 MHz Mode: USB Receiving MAIN display frequency : 0.030 MHz Mode: USB Receiving MAIN display frequency : 8.000 MHz Mode: USB Receiving MAIN display frequency : 15.000 MHz Mode: USB Receiving MAIN display frequency : 2
13、2.000 MHz Mode: USB Receiving MAIN display frequency : 30.000 MHz Mode: USB Receiving RX PLL-A RX PLL-A RX PLL-A RX PLL-A Connect an RF volt- meter to the CP701 (40MHz). Connect a DC volt- meter to the CP1 (LV1). Connect a DC volt- meter to the CP2 (LV2). Connect a DC volt- meter to the CP2 (LV2). M
14、aximum voltage 2.0 V 0.1 V Less than 3.0 V 6.0 V 0.1 V 6.0 V 0.1 V 6.0 V 0.1 V 6.0 V 0.1 V 6.0 V 0.1 V 6.0 V 0.1 V 1.8 V2.8 V 1.8 V2.8 V 1.8 V2.8 V 1.8 V2.8 V 1.8 V2.8 V RX PLL-A RX PLL-A RX PLL-A L702, L703 C154 Verify C222 C232 C242 C252 C262 C272 Verify Verify Verify Verify Verify 12 RX PLL-A UNI
15、T ADJUSTMENTSContinued HPL LOCK VOLTAGE (VCO6) R1 LO OUTPUT 2LO LOCK VOLTAGE R2 LO OUTPUT T2 LO OUTPUT RX SENSITIVITY (HF) IMAGE RESPONSE ADJUSTMENT ADJUSTMENTADJUSTMENT CONDITION MEASUREMENT VALUE POINT UNITLOCATIONUNITADJUST 12 1 1 1 1 1 2 1 MAIN display frequency : 45.0 MHz Mode: USB Receiving MA
16、IN display frequency : 14.999 MHz Mode: USB Receiving MAIN display frequency : 14.100 MHz Mode: USB Receiving MAIN display frequency : 14.100 MHz Mode: USB Receiving MAIN display frequency : 14.100 MHz Mode: USB Receiving Pre-set the IC-7800 as below condi- tion. MAIN display frequency : 14.150 MHz
17、Mode: USB Dual watch: OFF MAIN Ant.: ANT1 Pre-amp. 1: ON SUB AF: Minimum level Set R1228 to center position. Rotate L1058 to 8.5 turns in clock- wise direction. Rotate L1401 to 2 turns in clock- wise direction. Rotate L1402 to 2 turns in clock- wise direction. Rotate L1403 to 3.5 turns in clock- wis
18、e direction. Rotate L1404 to 3.5 turns in clock- wise direction. Receiving MAIN display frequency : 14.150 MHz Mode: USB Connect an SSG to ANT1 connec- tor and set as: Frequency : 14.1515 MHz Level: 1 V* (107 dBm) Modulation: OFF Receiving MAIN display frequency : 14.150 MHz Mode: USB Connect an SSG
19、 to ANT1 connec- tor and set as: Frequency : 14.0765 MHz Level: 50 mV* (13 dBm) Modulation: OFF Receiving RX PLL-A RX PLL-A RX PLL-A RX PLL-A RX PLL-A RX PLL-A Rear panel Rear panel Connect a DC volt- meter to the CP2 (LV2). Connect an DC volt- meter to the J351 (R1LO). Connect an DC volt- meter to
20、the CP3. Connect a spectrum analyzer to the J831 (R2LO). Connect a spectrum analyzer to the J561 (T2LO). Connect a DC volt- meter to the CP1102. Connect a DC volt- meter to the CP1103. Connect an AC milli- volt meter to the EXT SP jack with 8 load. Connect a spectrum analyzer to the EXT SP jack with
21、 8 load. 1.8 V2.8 V 2.25 dBm 0.25 dB 1.5 V 0.3 V Maximum level (10 dBm 3.0 dB) Maximum level (3.0 dBm 3.0 dB) 4.5 V 0.1 V 4.5 V 0.1 V Maximum audio level Mimimum image RX PLL-A RX PLL-A RX PLL-A RX PLL-A RX PLL-A RX PLL-A RX PLL-A RX PLL-A Verify R357 C546 L801, L834 L565, L566 R1101 R1132 L1408, L1
22、058 R1516, C1656 *This output level of a standard signal generator (SSG) is indicated as SSGs open circuit. 13 RX PLL-A UNIT ADJUSTMENTSContinued RX SENSITIVITY (50 MHz) IF THROUGH (50 MHz) ADJUSTMENT ADJUSTMENTADJUSTMENT CONDITION MEASUREMENT VALUE POINT UNITLOCATIONUNITADJUST 1 1 MAIN display freq
23、uency : 50.020 MHz Mode: USB Pre-amp. 2: ON Connect an SSG to ANT1 connec- tor and set as: Frequency : 50.0215 MHz Level: 0.32 V* (117 dBm) Modulation: OFF Receiving MAIN display frequency : 50.020 MHz Mode: USB Connect an SSG to ANT1 connec- tor and set as: Frequency : 64.455 MHz Level: 50 mV* (13
24、dBm) Modulation: OFF Receiving Rear panel Front panel Connect an AC milli- volt meter to the EXT SP jack with 8 load. S-meter Maximum audio level Mimimum level RX PLL-A RX PLL-A L1222 C1265 *This output level of a standard signal generator (SSG) is indicated as SSGs open circuit. 14 4 RX PLL-B UNIT