1、PAGE 1-3 PAGE 2-1 PAGE 2-16 PAGE 2-21 PAGE 3-2 TM 11-5820-520-10 O P E R A T O R S M A N U A L This copy is a reprint which includes current pages from Change 1. R A D I O S E T SA N / G R C - 1 0 6 ( N S N 5 8 2 0 - 0 0 - 4 0 2 - 2 2 6 3 ) A N / G R C - 1 0 6 A ( N S N 5 8 2 0 - 0 0 2 2 3 - 7 5 4 8
2、 ) H E A D Q U A R T E R S , D E P A R T M E N T O F T H E A R M Y 2 8 M A Y 1 9 8 4 T M 1 1 - 5 8 2 0 - 5 2 0 - 1 0 DANGEROUS VOLTAGES EXIST IN THIS EQUIPMENT Voltages as high as 128 volts ac, 3,000 volts dc, and 10,000 volts RF are used in the operation of Amplifier, Radio Frequency AM-3349/GRC-10
3、6. DANGEROUS VOLTAGES EXIST AT THE AM-3349/GRC-106 50-OHM LINE AND WHIP ANTENNA CONNECTORS Be careful when working around the antenna or antenna connectors. Radio- frequency voltages as high as 10,000 volts exist at these points. Operator and maintenance personnel should be familiar with the require
4、ments of TB SIG 291 before attempting installation or operation of Radio Set AN/GRC-106(*). DEATH ON CONTACT May result if operating personnel fail to observe safety precautions and fail to follow requirements of TB SIG 291. DONT TAKE CHANCES WARNING Adequate ventilation should be provided while usi
5、ng TRICHLOROTRIFLUORO- ETHANE. Prolonged breathing of vapor should be avoided. The solvent should not be used near heat or open flame; the products of decomposition are toxic and irritating. Since TRICHLOROTRIFLUOROETHANE dissolves natural oils, pro- longed contact with skin should be avoided. When
6、necessary, use gloves which the solvent cannot penetrate. If the solvent is taken internally, consult a physician immediately. TM 11-5820-529-10 C 1 Change No. 1 HEADQUARTERS DEPARTMENT OF THE ARMY Washington, DC, 15 May 1989 OPERATORS MANUAL RADIO SETS AN/GRC-106 (NSN 5820-00-402-2263) AN/GRC-106A
7、(NSN 5820-00-223-7548) TM 11-5820-520-10, 28 May 1984 is changed as follows: 1. Remove old pages and insert new pages as indicated below. New or changed material is indicated by a vertical bar in the margin of the page. Revised illustrations are indicated by a miniature pointing hand adjacent to the
8、 changed area. Remove pagesInsert pages a and c . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . a through d band d . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .None i and ii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i and ii 1-1 through 1-4 . . .
9、 . . . . . . . . . . . . . . . . . . . . . .1-1 through 1-4 1-7 and 1-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 and 1-8 2-9 and 2-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 and 2-10 2-15 through 2-20 . . . . . . . . . . . . . . . . . . . . . . . 2-15 through 2-2
10、0 2-23 through 2-26 . . . . . . . . . . . . . . . . . . . . . . . 2-23 through 2-26 2-29 and 2-30 . . . . . . . . . . . . . . . . . . . . . . . . . . 2-29 and 2-30 2-33 through 2-40 . . . . . . . . . . . . . . . . . . . . . . . 2-33 through 2-40 2-45 and 2-46 . . . . . . . . . . . . . . . . . . . .
11、. . . . . . 2-45 and 2-46 3-3 and 3-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 and 3-4 A-1 and A-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 and A-2 B-5 through B-7/(B-8 blank) . . . . . . . . . . . . . B-5 through B-7/(B-8 blank) 2. File this change sheet in front
12、 of the publication for reference purposes. Distribution authorized to the Department of Defense and DOD contractors only for official use or for administration or operational purposes. This determination was made on 9 February 1989. Other requests for this document will be referred to Commander, US
13、 Army Communications-Electronics Command and Fort Monmouth, ATTN: AMSEL-LC-ME-P, Fort Monmouth, NJ 07703-5000. DESTRUCTION NOTICE Destroy by any method that will prevent disclosure of contents or reconstruction of the document. TM11-5820-520-10 WARNING RADIOACTIVE MATERIAL CONTROLLED DISPOSAL REQUIR
14、ED ACCOUNTABILITY NOT REQUIRED STD RW-2 Meter, electrical indicating . . . . Ra226 . . . . . . 1.0uCi . . . . 6625-01-226-5681 Meter, electrical indicating . . . . Ra226 . . . . . . 1.0uCi . . . . 6625-00-226-5679 Meter, signal level . . . . . . . . . .Ra226 . . . . . . 0.6uCi . . . . 6625-00-226-56
15、80 Radiation Information:The following radiation information must be read and understood by all personnel before operating or repairing Radio Sets AN/GRC-106 and AN/GRC-106A. Radioactive materials are present in the above listed components of the AM-3349/GRC-106 and the RT-662/GRC. The components ar
16、e potentially hazardous when broken. See qualified medical personnel and the local Radiological Protection Officer (RPO) immediately, if you are exposed to or cut by broken components. First aid instructions are contained in TB 43-0116 and TB 43-0122. NEVER place radioactive components in your pocke
17、t. Use extreme care NOT to break radioactive components while handling them. NEVER remove radioactive components from cartons until you are ready to use them. If any of these components are broken, notify the local RPO immediately. The RPO will survey the immediate area for radiological contaminatio
18、n and will supervise the removal of broken components. The above listed radioactive components will NOT be repaired or disassembled. a TM11-5820-520-10 FIXED OPERATION WITH LONG RANGE ANTENNAS WARNING NEVER ERECT THESE LONG RANGE ANTENNAS DIRECTLY UNDER POWER LINES. IF YOU MUST ERECT THESE LONG RANG
19、E ANTENNAS NEAR POWER LINES, POWERLINE POLES OR TOWERS, OR BUILDINGS WITH OVERHEAD POWERLINE CONNECTIONS, NEVER PUT THE ANTENNA CLOSER THAN TWO TIMES THE ANTENNA HEIGHT FROM THE BASE OF THE POWER LINE, POLE, TOWER OR BUILDINGS, 100 FEET AWAY IS A GOOD SAFE ROUND NUMBER TO REMEMBER. NEVER ATTEMPT TO
20、ERECT ANY LONG RANGE ANTENNA WITHOUT A FULL TEAM. BEFORE ERECTING ANY LONG RANGE ANTENNA, INSPECT ALL THE PARTS MAKING UP THE ANTENNA KIT. DO NOT ERECT THE ANTENNA IF ANY PARTS ARE MISSING OR DAMAGED. DO AS MUCH OF THE ASSEMBLY WORK AS POSSIBLE ON THE GROUND. WHEN ERECTING THE ANTENNA, ALLOW ONLY TE
21、AM PERSONNEL IN THE ERECTION AREA. MAKE SURE THAT THE AREA FOR THE ANCHORS IS FIRM. IF THE GROUND IS MARSHY OR SANDY, GET SPECIFIC INSTRUCTIONS FROM YOUR CREW CHIEF OR SUPERVISOR ON HOW TO REINFORCE THE ANCHORS. WHEN SELECTING LOCATIONS FOR ANCHORS, AVOID TRAVELED AREAS AND ROADS. IF YOU CANNOT AVOI
22、D THESE AREAS, GET SPECIFIC INSTRUCTIONS FROM YOUR SUPERVISOR AS TO WHAT CLEAR- ANCE YOUR GUY WlRES AND ROPES MUST HAVE OVER THE TRAVELED AREAS AND ROAD. CLEARLY MARK ALL GUY WIRES AND ROPES WITH THE WARNING FLAGS OR SIGNS SUPPLIED BY YOUR UNIT. IN AN EMERGENCY, USE STRIPS OF WHITE CLOTH AS WARNING
23、STREAMERS. IF YOU SUSPECT THAT POWERLINES HAVE MADE ACCIDENTAL CONTACT WITH YOUR ANTENNA, STOP OPERATING, ROPE OFF THE ANTENNA AREA, AND NOTIFY YOUR SUPERIORS. IF THE WEATHER IN YOUR AREA CAN CAUSE ICE TO FORM ON YOUR LONG RANGE ANTENNA AND ITS GUY WIRES AND ROPES, ADD EXTRA GUYS TO SUPPORT THE SYST
24、EM. ROPE OFF THE AREA AND POST IT WITH WARNING SIGNS LIKE BEWARE OF FALLING ICE. DO NOT TRY TO ERECT ANY ANTENNA DURING AN ELECTRICAL STORM. KEEP A SHARP EYE ON YOUR ANCHORS AND GUYS. CHECK THEM DAILY AND lMMEDIATELY BEFORE AND AFTER BAD WEATHER. bChange 1 TM 11-5820-520-10 WARNING SERIOUS INJURY OR
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AN GRC 106 A_user_TM11 5820 520 10 _1984
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf