AN-URM-25B_RF_signal_generator_serv_user_TM11-5551B_1954.pdf
《AN-URM-25B_RF_signal_generator_serv_user_TM11-5551B_1954.pdf》由会员分享,可在线阅读,更多相关《AN-URM-25B_RF_signal_generator_serv_user_TM11-5551B_1954.pdf(123页珍藏版)》请在收音机爱好者资料库上搜索。
1、TM 11-5551B DEPARTMENT OF THE ARMY TECHNICAL MANUAL R. F. SIGNAL GENERATOR SET AN/URM-25B This copy is a reprint which includes current pages from change 1. DEPARTMENT OF THE ARMY JANUARY 1954 TM 11-5551B C 1 R. F. SIGNAL GENERATOR SET AN/URM-25B CHANGEHEADQUARTERS DEPARTMENT OF THE ARMY No. 1WASHIN
2、GTON, D.C., 19 November 1963 TM 11-5551B, 25 January 1954, is changed as follows: Page 1-1. Add paragraphs 1.1 and 1.2 after paragraph 1. 1.1. Index of Publications Refer to the latest issue of DA Pam 310-4 to determine whether there are new editions, changes or additional publications pertaining to
3、 the equipment. DA Pam 3104 is an index of current technical manuals, technical bulletins, Supply manuals (types 4, 6, 7, 8, and 9), supply bulletins, lubrication orders, and modification work orders available through publications supply channels. The index lists the individual parts (-10, -20, -35P
4、, etc) and the latest changes to and revisions of each equipment publication. 1.2. Forms and Records aReports of Maintenance and Unsatisfactory Equipment. Use equipment forms and records in accordance with instructions in TM 38-750. bReport of Damaged or Improper Shipment.Fill out and forward DD For
5、m 6 (Report of Damaged or Improper Shipment) as prescribed in AR 700-58 (Army), NAVASANDA Publication 378 (Navy), and AFR 71-4 (Air Force). cReporting of Equipment Manual Improvements. The direct reporting by the individual user of errors, omissions, and recommendations for improving this manual is
6、authorized and encouraged. DA Form 2028 (Recommended changes to DA technical manual parts lists or supply manual 7, 8, or 9) will be used for reporting these improvements. This form will be completed in triplicate using pencil, pen, or typewriter. The original and one copy will be forwarded direct t
7、o Commanding Officer, U. S. Army Electronics Material Support Agency, ATTN: SELMS-MP, Fort Monmouth, N. J. 07703. One information copy will be furnished to the individuals immediate supervisor (officer, noncommissioned officer, supervisor, etc). Page 5-1. Delete paragraph 1 and substitute: 1. Scope
8、of Maintenance The maintenance duties assigned to the operator and organizational repairman of the equipment are listed below together with a reference to the paragraphs covering the specific maintenance functions. aDaily preventive maintenance checks and services (par. 1.3). bWeekly preventive main
9、tenance checks and services (par. 1.4). cMonthly preventive maintenance checks and services (par. 1.5). dQuarterly preventive maintenance checks and services (par. 1.6). eCleaning (par. 1.7). fTouchup painting (par. 1.8). gRoutine check (table 5-1). Add paragraphs 1.1 through 1.8 after paragraph 1.
10、1.1. Preventive Maintenance Preventive maintenance is the systematic care, servicing, and inspection of equipment to prevent the occurrence of trouble, to reduce downtime, and to assure that the equipment is serviceable. aSystematic Care. The procedures given in paragraphs 1.3 through 1.7 cover rout
11、ine systematic care and cleaning essential to proper upkeep and operation of the equipment. b.Preventive Maintenance Checks and Services. The preventive maintenance checks and services charts (par. 1.3- 1.6) outline functions to be performed at specific intervals. These checks and services are to ma
12、intain Army electronic equipment in a combat serviceable condition; that is, in good general (physical) condition and in good operating condition. To assist operators in maintaining combat serviceability, the charts indicate what to check, how to check, and what the normal conditions are; the refere
13、nces column lists the tables or manuals that contain detailed repair or 1 replacement procedures. If the defect cannot be remedied by performing the corrective actions listed, higher echelon maintenance or repair is required. Records and reports of these checks and services must be made in accordanc
14、e with the requirements set forth in TM 38-750. 1.2. Preventive Maintenance Checks and Services Periods Preventive maintenance checks and services of the equipment are required daily, weekly, monthly and quarterly. aParagraph 1.3 specifies the checks and services that must be accomplished daily (or
15、at least once each week if the equipment is maintained in standby condition). b.Paragraphs 1.4, 1.5, and 1.6 specify additional checks and services that must be performed on a weekly, monthly, and quarterly basis, respectively. 1.3. Daily Preventive Maintenance Checks and Services Chart Sequence No.
16、 ItemProcedureReferences 1Completness.See that the equipment is complete.Table 1-1 2Exterior surface.Clean the exterior surfaces, including the panel, dial windows, and meter glass (par. 1.7). Check all glass and indicator lens for cracks. 3Connectors.Check the tightness of all connectors 4Controls
17、and indicators.While making the operating checks (item 5), observe that the mechanical action of each knob, dial, and switch is smooth and free of external or internal binding, and that there is no excessive looseness. Also, check the meter for sticking or bent pointer. 5Operation.Operate the equipm
18、ent according to table 5-1.Table 5-1 1.4. Weekly Preventive Maintenance Checks and Services Chart Sequence No. ItemProcedureReferences 1Cables.Inspect or, cables and wires for chafed, cracked, or frayed insulation. Replace connectors that are broken, arced, stripped, or worn excessively. None 2Handl
19、es and latch.Inspect handles and latches for looseness. Replace or tighten as necessary. None 3Metal surfaces.Inspect exposed metal surfaces for rust and corrosion. Touchup paint as required (par. 1.8). None 1.5. Monthly Preventive Maintenance Checks and Services Chart Sequence No. ItemProcedureRefe
20、rences 1Pluckout items.Inspect seating of pluckout items. Make certain that tube clamps grip tube bases tightly None 2Jacks .Inspect jacks for snug fir and good contact.None 3Transformer terminals.Inspect the terminals on the power transformer. All nuts must be tight. There should be no evidence of
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AN URM 25 B_RF_signal_generator_serv_user_TM11 5551 B_1954
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-196943.html



Marshall-9100-62-02-Schematic电路原理图.pdf