AN-UGC-74A_terminal_communications_user_TM11-5815-602-10_1983.pdf
《AN-UGC-74A_terminal_communications_user_TM11-5815-602-10_1983.pdf》由会员分享,可在线阅读,更多相关《AN-UGC-74A_terminal_communications_user_TM11-5815-602-10_1983.pdf(226页珍藏版)》请在收音机爱好者资料库上搜索。
1、A R M YTM 11-5815-602-10 NAVY EE161-DM-OPI-010/E154UGC74 AIR FORCETO 31W4-2UGC74-1 OPERATORS MANUAL EQUIPMENT DESCRIPTION Page 1-5 OPERATING INSTRUCTIONS Page 2-0 DESCRIPTION OF CONTROLS Page 2-1 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) Page 2-39 OPERATOR MAINTENANCE INSTRUCTIONS Page 3-1 T
2、ROUBLESHOOTING Page 3-3 TERMINAL, COMMUNICATIONS AN/UGC-74A(V)3 (NSN 5815-01-062-8194) SUBJECT INDEX Page Index-1 DEPARTMENTS OF THE ARMY, THE NAVY, AND THE AIR FORCE 2 3 S E P T E M B E R 1 9 8 3 may HIGH VOLTAGE is used in the operation of this equipment DEATH ON CONTACT result if personnel fail t
3、o observe safety precautions Never work on electronic equipment unless there is another person nearby who is familiar with the operation and hazards of the equipment and who is competent in administering first aid. When the technician is aided by operators, he must warn them about dangerous areas. W
4、henever possible, the power supply to the equipment must be shut off before beginning work on the equipment. Take particular care to ground every capacitor likely to hold a dangerous potential. When working inside the equipment, after the power has been turned off, always ground every part before to
5、uching it. Be careful not to contact high voltage input connections of 115/230 volt ac when installing or operating this equipment. Whenever the nature of the operation permits, keep one hand away from the equipment to reduce the hazard of current flowing through vital organs of the body. For Artifi
6、cial Do not be misled by the term “low voltage”. may cause death under adverse conditions. Respiration, refer to FM 21-11. Potentials as low as 50 volts TM 11-5815-602-10 EE161-DM-OPI-010/E154UGC74 TO 31W4-2UGC74-1 Adequate ventilation should be provided while using TRICHLOROTRIFLUOROETHANE. Prolong
7、ed breathing of vapor should be avoided. The solvent should not be used near heat or open flame; the products of decomposition are toxic and irritating. Since TRICHLOROTRIFLUOROETHANE dissolves natural oils, prolonged contact with skin should be avoided. When necessary use gloves which the solvent c
8、annot penetrate. If the solvent is taken internally, consult a physician immediately. Lithium organic batteries or cells are used in this equipment. They are potentially hazardous if misused or tampered with before, during, or after discharge. The following precautions must be strictly observed to p
9、revent possible injury to personnel or equipment damage: DO NOT heat, incinerate, crush, puncture, disassemble, or otherwise mutilate the batteries. DO NOT short circuit, recharge, or bypass internal fuse. DO NOT store in equipment during long period of nonuse in excess of 30 days. TURN OFF the equi
10、pment immediately if you detect battery compart- ment becoming unduly hot, hear battery cells venting (hissing sound), or smell irritating sulphur dioxide gas. Remove and dispose of the battery only after it is cool (30-60 minutes). A TM 11-5815-602-10 EE161-DM-OPI-010/E154UGC74 TO 31W4-2UGC74-1 SAF
11、ETY STEPS TO FOLLOW IF SOMEONE IS THE VICTIM OF ELECTRICAL SHOCK DO NOT TRY TO PULL OR GRAB THE INDIVIDUAL IF POSSIBLE , TURN OFF THE ELECTRICAL POWER IF YOU CANNOT TURN OFF THE ELECTRICAL POWER, PULL, PUSH, OR LIFT THE PERSON TO SAFETY USING A WOODEN POLE OR A ROPE OR SOME OTHER INSULATING MATERIAL
12、 SEND FOR HELP AS SOON AS POSSIBLE AFTER THE INJURED PERSON IS FREE OF CONTACT WITH THE SOURCE OF ELECTRICAL SHOCK, MOVE THE PERSON A SHORT DISTANCE AWAY AND IMMEDIATELY START ARTIFICIAL RESUSCITATION B TM 11-5815-602-10 EE161-DM-OPI-010/E154UGC74 TO 31W4-2UGC74-1 TECHNICAL MANUAL No. 11-5815-602-10
13、 DEPARTMENTS OF THE ARMY, THE NAVY, No. EE161-DM-OPl-010/E154UGC74AND THE AIR FORCE TECHNICAL ORDER No. 31W4-2UGC74-1WASHINGTON, DC, 23 September 1983 CHAPTER 1 Section I II CHAPTER 2 Section I II III IV CHAPTER 3 Section I II APPENDIX A B OPERATORS MANUAL TERMINAL, COMMUNICATIONS AN/UGC-74A(V)3 (NS
14、N 5815-01-062-8194) REPORTING OF ERRORS AND RECOMMENDING IMPROVEMENTS You can help improve this manual. If you find any mistakes or if you know of a way to improve the procedures, please let us know. Mail your letter, DA Form 2028 (Recommended Changes to Publications and Blank Forms), or DA Form 202
15、8-2 located in back of this manual direct to: Commander, US Army Communications-Electronics Command and Fort Monmouth, ATTN: DRSEL-ME-MP, Fort Monmouth, New Jersey 07703. For Air Force, submit AFTO Form 22 (Technical Order System Publica- tion Improvement Report and Reply) in accordance with paragra
16、ph 6-5, Section VI, T.O. 00-5-1. Forward direct to prime ALC/MST. For Navy, mail comments to the Commander, Naval Electronics Systems Command, ATTN: ELEX 8122, Washington, DC 20360. In either case, a reply will be furnished direct to you. TABLE OF CONTENTS HOW TO USE THIS MANUAL . . . . . . . . . .
17、. . . . . . . . . . . . . . . . . . . . . . . . INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18、 . . . . . . . . . . . . . . . . . . . Operation Under Usual Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation Under Unusual Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting Procedures . . . . . .
19、. . . . . . . . . . . . . . . . . . . . . . . . . . . . Operator Maintenance Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . COMPONENTS OF END ITEM LIST. . . . . . . . . . . .
20、 . . . . . . . . . . . . . . . PAGE iii 1-0 1-1 1-5 2-0 2-1 2-39 2-44 2-86 3-1 3-1 3-6 A-1 B-1 *This manual supersedes the operators portion of TM 11-5815-602-12, 30 November 1979, including all changes. i TM 11-5815-602-10 EE161-DM-OPI-010/E154UGC74 TO 31W4-2UGC74-1 TABLE OF CONTENTS - Continued AP
21、PENDIX C D E F G H I J ADDITIONAL AUTHORIZATION LIST ITEMS . . . . . . . . . . . . . . . . . . . . . . . EXPENDABLE SUPPLIES AND MATERIALS LIST . . . . . . . . . . . . . . . . . . . . AMERICAN NATIONAL STANDARD CODE FOR INFORMATION INTERCHANGE (ASCII) AND KEYBOARD TABLES . . . . . . . . . . . . . .
22、. . . OPERATOR EXAMPLES - SYSTEM COMMANDS . . . . . . . . . . . . . . . . . . . . OPERATOR EXAMPLES - PARAMETER SUBCOMMANDS . . . . . . . . . . . . . OPERATOR EXAMPLES - EDIT SUBCOMMANDS . . . . . . . . . . . . . . . . . . . . SUMMARY LISTS OF OPERATOR ACTIONS AND TERMINAL RESPONSES . . . . . . . .
23、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFERENCE TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table J-1. System Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . Table J-2. Error Message List . . . . . . . .
24、 . . . . . . . . . . . . . . . . . . . . Table J-3. Shortest Acceptable Forms for System Commands and Subcommands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PAGE C-1 D-1 E-1 F-1 G-1 H-1 I-1 J-1
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AN UGC 74 A_terminal_communications_user_TM11 5815 602 10 _1983
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-197021.html



Marshall-9100-62-02-Schematic电路原理图.pdf