1、ARMYTM 11-5895-1180-10 NAVYEE125-JC-OPl-010/PSC3 AIR FORCE MARINE CORPS OPERATORS MANUAL RADIO SET AN/PSC-3 (NSN 5820-01-145-4943) 31R2-2PSC3-1 TM 5895-10/1 Change No. 1 TM115895-1180-10 EE125-JC-OPI-01A/PSC3 TO 31R2-2PSC3-1 TM 5898-10/1 DEPARTMENTS OF THE ARMY, THE NAVY, AND THE AIR FORCE AND HEADQ
2、UARTERS, MARINE CORPS Washington, DC, 15 January 1992 Operators Manual RADIO SET AN/PSC-3 (NSN 5820-01-1454943) (EIC: L2S) TM 11-5895-1180-10 / EE125-JC-OPI-010/PSC 3/ TO 31R2- 2PSC3-1 / TM 5895-10/1, 15 February 1988, is changed as follows: 1. Pen and ink change. On front cover, following NSN, add:
3、 (EIC:L2S). 2. Remove old pages and insert new pages as indicated below. New or changed material is indicated by a vertical bar in the margin of the page. Remove pagesInsert pages i and iii and ii 1-1 and 1-211 and 1-2 2-5 and 2-82-5 and 2-6 A-1 through A-4A1 through A-4 B-1 through B-4B-1 through B
4、-4 C-1 and C2C-1 and C2 3. File this change sheet in front of the manual for reference purposes. Distribution authorized to US Government agencies and their contractors for official use or for administrative or operational purposes only. This determination was made on 15 June 1991. Other requests fo
5、r this document will be referred to Commander, US Army Communications-Electronics Command and Fort Monmouth, ATTN: AMSEL-LC-LM-LT, Fort Monmouth, New Jersey 07703-5007. DESTRUCTION NOTICE - Destroy by any method that will prevent disclosure of contents or reconstruction of the document. By Order of
6、the Secretary of the Army: GORDON R. SULLIVAN Official: MILTON H. HAMILTON Administrative Assistant to the Secretary of the Army 00297 By Order of the Marine Corps: H. E. REESE Deputy for Support Marine Corps Research Development and Acquisition Command By Order of the Secretary of the Navy: ROBERT
7、AILES Rear Admiral, United States Navy Command, Space and Naval Warfare Systems Command By Order of the Secretary of the Air Force: LARRY D. WELSH General, United States Air Force Chief of Staff Official: CHARLES D. McDONALD General, United States Air Force Commander, Air Force Logistics Command Dis
8、tribution: To be distributed in accordance with DA Form 12-51-E, block 1587, Operator Maintenance requirements for TM 11-5895-1180-10. WARNING ELECTROMAGNETIC RADIATION Do NOT stand in direct path of the Medium Gain Antenna when power is on. Do NOT work on cables while power is on. Transmit antenna
9、cables conduct radio frequency energy that can cause fatal internal burns and electrical shock. Ensure that power is off before working on antenna or connectors. If you feel a slight warming effect while near this equipment, MOVE AWAY QUICKLY! CLEANING Adequate ventilation should be provided while u
10、sing TRl- CHLOROTRIFLUOROETHANE.Prolonged breathing of vapor should be avoided. The solvent should not be used near heat or open flame, the products of decomposition are toxic and irritating.Since TRICHLOROTRIFLUOROETHANE dissolves natural oils, prolonged contact with skin should be avoided. When ne
11、cessary, use gloves which the solvent cannot penetrate. If the solvent is taken internally, consult a physician immediately. Compressed air shall not be used for cleaning purposes except where reduced to less than 29 pounds per square inch (psi) and then only with effective chip guarding and personn
12、el protective equipment. Do not use compressed air to dry parts when TRICHLOROTRIFLUOROETHANE has been used. Compressed air is dangerous and can cause serious bodily harm if protective means or methods are not observed to prevent chips or particles (of whatever size) from being blown into the eyes o
13、r unbroken skin of the operator or other personnel. BLACKOUT When operating Radio Set AN/PSC-3 in enemy territory, bright lights will make it easy for the enemy to detect your presence. Use blackout procedures to prevent detection by the enemy. A SAFETY STEPS TO FOLLOW IF SOMEONE IS THE VICTIM OF EL
14、ECTRICAL SHOCK DO NOT TRY TO PULL OR GRAB THE INDIVIDUAL IF POSSIBLE, TURN OFF THE ELECTRICAL POWER IF YOU CANNOT TURN OFF THE ELEC- TRICAL POWER, PULL, PUSH, OR LIFT THE PERSON TO SAFETY USING A DRY WOODEN POLE OR A DRY ROPE OR SOME OTHER INSULATING MATERIAL SEND FOR HELP AS SOON AS POSSIBLE AFTER
15、THE INJURED PERSON IS FREE OF CONTACT WITH THE SOURCE OF ELECTRICAL SHOCK, MOVE THE PERSON A SHORT DISTANCE AWAY AND IMMEDIATELY START ARTIFICIAL RESUSCITATION B HIGH VOLTAGE is used in the operation of this equipment DEATH ON CONTACT may result if personnel fail to observe safety precautions. Never
16、 work on electronic equipment unless there is another person nearby who is familiar with the operation and hazards of the equipment and who is competent in administering first aid. When technicians are aided by operators. they must be warned about dangerous areas. Whenever possible, the power supply
17、 to the equipment must be shut off before beginning work on the equipment. Take partic- ular care to ground every capacitor likely to hold a dangerous potential. When working inside the equipment, after the power has been turned off, always ground every part before touching it. Be careful not to con
18、tact high-voltage connections or 115 volt ac input connections when installing or operating this equip- ment. Whenever the nature of the operation permits, keep one hand away from the equipment to reduce the hazard of current flowing through the body. WARNING:DO NOT BE MISLED BY THE TERM “LOW VOLTAG
19、E.” POTENTIALS AS LOW AS 50 VOLTS MAY CAUSE DEATH UNDER ADVERSE CONDITIONS. For Artificial Respiration, refer to FM 21-11. c WARNING A lithium-sulfur dioxide (Li-SO2) battery used with the RT-1402A/G contains pressurized sulfur dioxide (SO2) gas. The gas is toxic, and the battery MUST NOT be abused
20、in any way which may cause the battery to rupture. Do not heat, short circuit, crush, puncture, mutilate, or disassemble batteries. Do not use any battery which shows signs of damage, such as bulging, swelling, disfigurement, brown liquid in the plastic wrap, a swollen plastic wrap, etc. Do not test
21、 Li-SO2 batteries for capacity, Do not recharge Li-SO2 batteries. Do not use water to extinguish Li-SO2 battery fires if a shock hazard exists due to high voltage electrical equipment in the immediate vicinity (i.e., greater than 30 volts, alternating current (ac) or direct current (dc). If the batt
22、ery compartment becomes hot to the touch, if - you hear a hissing sound (i.e., battery venting), or smell irritating sulfur dioxide gas, IMMEDIATELY turn OFF the equipment.Remove the equipment to a well ventilated area or leave the area. . Do not use a HaIon type fire extinguisher on a lithium batte
23、ry fire. In the event of a fire, near a lithium battery(ies), rapid cooling of the battery(ies) is important. Use a carbon dioxide (CO2) extinguisher. Control of the equipment fire, and cooling, may prevent the battery from venting and potentially exposing lithium metal.In the event that lithium met
24、al becomes involved in fire, the use of a graphite based Class D fire extinguisher is recommended, such as Lith-X or MET-L-X, Do not store lithium batteries with other hazardous materials and keep them away from open flame or heat. D TM 11-5895-1180-10 EE125-JC-OPl-01A/PSC-3 31R2-2PSC3-1 TM 5895-10/
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AN PSC3_user_TM11 5895 1180 10 _1988
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf