1、PC CONTROL COMMAND REFERENCE FOR THE TS-590S TRANSCEIVER October/01/2010 PC CONTROL COMMAND REFERENCE GUIDE ABOUT THIS REFERENCE GUIDE All descriptions in this reference guide are for the users convenience. Kenwood does not support or warrantee this documentation in any way. CONNECTING TO A PC You c
2、an connect the TS-590S transceiver to a PC COM port using a traditional RS-232C connector, or to a USB port using a USB 2.0 (AB type) cable. Through the transceiver menu, select a baud rate for communications between the PC and the transceiver. Using a RS-232C Straight Cable Directly connect the RS-
3、232C straight cable between the COM port of the PC and the COM terminal of the transceiver. Using a USB Cable When using a USB cable, you must first pre- install a virtual COM port driver on the PC. Then, connect the USB cable A-connector to the USB port of the PC and the B-connector the USB termina
4、l of the transceiver. Note: Operation is not guaranteed when connecting through a USB hub. CONTROL OPERATION Most computers handle data in the form of “bits” and “bytes”. A bit is the smallest piece of information a computer can handle. A byte is composed of eight bits. This is the most convenient f
5、orm for most computer data. This data may be sent in the form of either serial or parallel data strings. The parallel method is faster but more complicated, while the serial method is slower and requires less complicated equipment. The serial form is, therefore, a less expensive alternative. Serial
6、data transmission uses time-division methods over a single line. Using a single line also offers the advantage of reducing the number of errors due to line noise. Theoretically, only three lines are required to control the transceiver via the computer: Transmit data Receive data Ground From a practi
7、cal standpoint however, it is also necessary to incorporate some means of controlling when this data transfer will occur. The computer and transceiver cannot be allowed to send data at the same time! The required control is achieved by using the RTS and CTS lines. For example, the transceiver is pla
8、ced into the transmit mode whenever the character string “TX;” is sent from the computer. The character string “TX;” is called a computer control command; it tells the transceiver what to do. There are numerous commands available for control of the transceiver. These commands may be incorporated int
9、o a computer program written in any high level language. Programming methods vary from computer to computer; refer to the instruction manuals provided with the terminal program and computer. 2 PC CONTROL COMMAND REFERENCE GUIDE Command A command consists of 2 characters. You may use either lower or
10、upper case characters. The commands available for this transceiver are listed in the PC Control Command Tables, beginning on page 3. Parameters Parameters are used to specify information necessary to implement the desired command. The parameters to be used for each command are predetermined. The num
11、ber of digits assigned to each parameter is also predetermined. Refer to the PC Control Command Tables page 3 to configure the appropriate parameters. When configuring parameters, be careful not to make the following mistakes. Correct parameter example: “IS+000;” IS000; Not enough parameters specifi
12、ed (No direction given for the IF shift) IS+00; Not enough digits (Only three frequency digits given) IS_+_000; Unnecessary characters (spaces) between parameters IS+0000; Too many digits (Five frequency digits given) Note: If a particular parameter is not applicable to this transceiver, the paramet
13、er digits should be filled using any character except the ASCII control codes (00 to Fh) and the terminator (;). Terminator To signal the end of a command, it is necessary to use a semicolon (;). The digit where this special character must appear differs depending on the command used. Error Messages
14、 In addition to the Answer command, the transceiver can send the error messages listed below. Error Message Reason for Error ?; Command syntax was incorrect. Command was not executed due to the current status of the transceiver (even though the command syntax was correct). Note: Occasionally, this m
15、essage may not appear due to microprocessor transients in the transceiver. E; A communication error occurred, such as an overrun or framing error during a serial data transmission. O; Receive data was sent but processing was not completed. COMPUTER CONTROL COMMANDS A computer control command is comp
16、osed of a 2 letter alphabetical command name, a set of parameters, and the terminator that signals the end of the command. Example: Command to set VFO A to 7 MHz FA 00007000000 ; Alphabetical command Parameters Terminator Commands can be classified as shown below: Computer control commands Input com
17、mand (input to the transceiver) Set command (sets a particular condition) Read command (reads an answer) Output command (from the transceiver) Answer command (transmits a condition) For example, note the following in the case of the above FA command (Frequency of VFO A): To set the frequency to 7 MH
18、z, the following command is sent from the computer to the transceiver: “FA00007000000;” (Set command) To read the frequency of VFO A, the following command is sent from the computer to the transceiver: “FA;” (Read command) When the Read command above has been sent, the following command is returned
19、to the computer: “FA00007000000;” (Answer command) Note: Do not use the control characters 00 to Fh since they are either ignored or cause a “?” answer. Program execution may be delayed while turning the Tuning control rapidly. Receive data is not processed if the frequency is entered from the keypa
20、d. 3 PC CONTROL COMMAND REFERENCE GUIDE PC CONTROL COMMAND TABLES AC Sets or reads the internal antenna tuner status. Parameters: P 0: RX-AT THRU : RX-AT IN P2 0: TX-AT THRU : TX-AT IN P3 0: Stop Tuning (Set)/ Tuning is stopped (Answer) : Start Tuning (Set)/ Tuning is active (Answer) The setting can
21、not be performed for RX IN/THRU AT Tuning will not begin when using the TX THRU status. To begin tuning, you must use command “AC”. Set 234567890 ACPP2P3; Read 234567890 AC; Answer 234567890 ACPP2P3; AG Sets or reads the AF gain. Parameters: P 0: Always 0 P2 000 (minimum) 255 (maximum) Set 234567890
22、 AGPP2P2P2; Read 234567890 AGP; Answer 234567890 AGPP2P2P2; AI Sets or reads the Auto Information (AI) function ON/ OFF. Parameters: P 0: AI OFF 2: AI ON When AI is ON, the respective response command is output when the parameter is changed by the command with the response command. AI turns OFF when
23、 the transceiver power is turned OFF. Set 234567890 AIP; Read 234567890 AI; Answer 234567890 AIP; AN Selects the antenna connector ANT/ ANT2. Parameters: P 0: ANT : ANT2 9: No change P2 0: RX ANT is not used : RX ANT is used 9: No change P3 0: Drive Out OFF : Drive Out ON 9: No change When setting t
24、he command, enter only the parameters you are changing. For parameters you are not changing, enter “9”. For a response command, parameter P, P2, and P3 cannot be “9”. Set 234567890 ANPP2P3; Read 234567890 AN; Answer 234567890 ANPP2P3; 4 PC CONTROL COMMAND REFERENCE GUIDE AS Sets or reads the Auto Mo
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- TS 590 S_PC_control_user
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf