TV-7_A_B_D_tube_tester_serv2_TM11-6625-274-35_1960.pdf
《TV-7_A_B_D_tube_tester_serv2_TM11-6625-274-35_1960.pdf》由会员分享,可在线阅读,更多相关《TV-7_A_B_D_tube_tester_serv2_TM11-6625-274-35_1960.pdf(78页珍藏版)》请在收音机爱好者资料库上搜索。
1、TM 11-6625-274-35 DEPARTMENT OF THE ARMY TECHNICAL MANUAL FIELD AND DEPOT MAINTENANCE MANUAL TEST SETS, ELECTRON TUBE TV-7/U, TV-7A/U, TV-7B/U, AND TV-7D/U This reprint includes all changes in effect at the time of publication: Changes 4 and 5. HEADQUARTERS, DEPARTMENT OF THE ARMY 30 JUNE 1960 W A R
2、 N I N G DANGEROUS VOLTAGES EXIST IN THIS EQUIPMENT Be careful when working on the 330- and 154-volt ac power supply circuits, on the 115-volt ac line connections, and on terminal board E106. Serious injury or death mayresuIt from contact with these points. DONT TAKE CHANCES! Changes in force: C 4 a
3、nd C 5 TM 11-6625-274-35 C 5 CHANGE No. 5 HEADQUARTERS DEPARTMENT OF THE ARMY WASHINGTON, DC, 30 March 1976 Direct Support, General Support, and Depot Maintenance Manual TEST SETS, ELECTRON TUBE TV-7/U, TV-7A/U, TV-7B/U, AND TV-7D/U TM 11-662527435, 30 June 1960, is changed as follows: Pages, paragr
4、aph 1b lines 2 and 3. TM 11-6625- 274-12P and TM 11-6625-274-35P” is changed to read TM 11-6625-274-25P. Subparagraph c is superseded as follows: c. You can help improve this manual by calling attention to errors and by recommending im- provements and stating your reasons for the recommendations. Yo
5、ur letter or DA Form 2028 (Recommended Changes to Publications and Blank Forms) should be mailed direct to Com- mander, US Army Electronics Command, ATTN: DRSEL-MA-Q, Fort Monmouth, NJ 07703. A reply will be furnished direct to you. Page 9, paragraph 7b(2), line 9. Change “121” to read “117.” Page 4
6、9, paragraph 36c, chart, performance stan- dard column. Make the following changes: Step 2b. Change “150 volts 3 to read “150 volts 6.” Step 2d. Change “130 volts 3 to read “130 volts 6.” Step 4, Performance stardard column: b(4). Change “0.65 to 0.72” to read “0.62 to 0.75.” c(4). Change “1.06 to 1
7、.16” to read “1.00 to 1.22.” d(4). Change “1.26 to 1.42” to read “1.21 to 1.47.” e(4). Change “1.90 to 2.10” to read “1.80 to 2.20.” g(4). Change 2.58 to 2.85” to read “2.45 to 2.99.” h.(4). Change “3.25 to 3.60” to read “3.09 to 3.77.” i(4). Change “4.30 to 4.75” to read “4.08 to 4.98.” j(4). Chang
8、e “5.15 to 5.68” to read “4.88 to 5.96.” k(4). Change “6.2 to 6.8” to read “5.85 to 7.15.” l(4). Change “7.32 to 8.1” to read “6.94 to 8.48.” n(4). Change “9.6 to 10.8” to read “9.18 to 11.22.” o(4). Change “12.1 to 13.3” to read 11.4 to 14.0.” p(4). Change “19 to 21” to read “18.0 to 22.0.” q(4). C
9、hange “25.3 to 28” to read “24.0 to 29.4.” r(4). Change “35.2 to 39” to read “33.4 to 40.8.” t(4). Change “51.5 to 57” to read “48.9 to 59.7.” u(4). Change “74 to 82” to read “70.2 to 85.8.” v(4). Change 115 to 127” to read “108.9 to 133.1.” Page 51, paragraph 38, Performance standard column. Make t
10、he following changes: 2c. Change “150 volts 3” to read “150 volts 6. 2d. Change “130 volts3 to read “130 volts to 6.” 2e. Change “40 volts 2 (4 volts 1)” to read “40 volts L2 (4 volts Y1 (F range, TV-7D/U only).” 2f. Delete “(F range, TV-7D/U only).” 2g. The chart is superseded as follows: 1 g. Fila
11、ment Voltage. Page 55, appendix. Delete TM 11-6625-274-20P” and TM 11-6625-274-35P” in their entirety and sub- stitute: TM 11-6625-274-25POrganizational, DS, GS, and Depot Maintenance Repair Parts and Special Tool Lists: Test Sets, Electron Tube TV-7/U, TV-7A/U, TV-7B/U, and TV-7D/U. 2 By Order of t
12、he secretary of the Army Official: PAUL T. SMITH Major General, United States Army The Adjusted General Distribution: Active Army: USMA (2) COE (1) TSG (1) USAARENBD (1) DARCOM (1) TRADOC (2) ARADCOM (2) ARADCOM Rgn (2) OS Maj Comd (4) MICOM (2) LOGCOMDS (3) TECOM (2) USAIB (2) USAEUR (4) USACC (4)
13、MDW (1) Armies (2) Corps (2) HISA (Ft Monmouth) (33) Svc Colleges (1) USASESS (5) USAADS (2) USAFAS (2) USAARMS (2) USAIS (2) USAES (2) USAINTCS (3) MAAG (1) USARMIS (1) SIGFLDMS (1) USAERDAA (1) USAERDAW (1) Instls (1) except Fort Gordon (10) Fort Huachuca (10) Fort Carson (5) FRED C. WEYAND Genera
14、l, United States Army Chief of Staff Fort Gillem (10) LBAD (14) SAAD (30) TOAD (14) SHAD (3) Units org under fd TOE: 11-35 1136 11-37 11-38 11-39 1145 11-46 11-85 11-86 11-87 11-95 11-96 11-97 11-98 11-117 11-127 11-137 11-147 11-215 11-216 11-217 11-218 11-225 11-226 11-237 11-247 11-347 11-357 11-
15、358 11377 Ft Richardson (ECOM Ofc) (2) 11-500 (U-AC) NC State AC (3), Units Same as Active Army. USAR: None For explanation of abbreviations used see AR 310-50. GPO 901-492 3 Change in force: C 4 TM 11-6625-274-35 *C 4 CHANGE HEADQUARTERS DEPARTMENT OF THE ARMY No. 4 WASHINGTON, D.C., 8 July 1966 DS
16、, GS, and Depot Maintenance Manual TEST SETS, ELECTRON TUBE TV-7/U, TV-7A/U, TV-7B/U, AND TV-7D/U TM 11-6625-274-35, 30 June 1960, is changed as follows: Page S. paragraph 1. Make the following changes: Delete subparagraph c as changed by C 3, 13 December 1963, and Substitute: c. The direct reportin
17、g by the individual user of errors, omissions, and recommendations for im- proving this manual is authorized and encouraged. DA. Form 2028 (Remmmended Changes to DA Publications) will be used for reporting these im- provement recommendations. This form will be completed using pencil, pen, or typewri
18、ter and forwarded direct to Commanding General, U.S. Army Electronics Command, ATTN: AMSEL- MR-NMP-AD, Fort Monmouth, N.J. 07703. Delete paragraph 1.1 as added by C 3,13 Decem- ber 1963, and substitute: 1.1. Index of Publications Refer to the latest issue of DA Pam 310-4 to determine whether there a
19、re new editions, changes, or additional publications pertaining to the equip- ment. DA Pam 310-4 is an index of current tech- nical manuals, technical bulletins, supply manuals (types 7, 8, and 9), supply bulletins, lubrication orders, and modification work orders available through publications supp
20、ly channels. The index lists the individual parts (-10, -20, -35P, etc.) and the Iatest changes to and revisions of each equip- ment publication. Page 21, paragraph 16c, chart, step 3, “Correc- tion” column, item 2. (As changed by C 3, 13 Dec 63) Change “resistance of” to transformer. Page 38. (As c
21、hanged by C 3,13 Dec 63) Delete paragraph 17 and substitute: 17. Dc Resistance of Transformer T101 The dc resistances of the transformer windings should be checked when the sc voltage readings vary from those shown in figures 42, 43, and . Resistance measurements are taken to locate shorts between w
22、indings, shorts to ground, open windings, and high resistance connetions. The dc resistances of the transformer windings will vary widely with each manufacturers design and should not be the determining factor for re- replacement. Typical measurements taken from three different Test Sets, Electron T
23、ube TV-7 ()/ U are shown in the following chart: Page 39, paragraph 22. (As changed by C 3,18 Dee. 63) Change paragraph 22 to 23 and add the following note after the paragraph heading. Note. Be sure to perform the plate voltage and line ad- just circuit test before performing the blat voltage test.
24、Page 40, paragraph 23. (As changed by C 3, 13 Dec. 63) Change paragraph 23 to 22, and add the following note after the paragraph heading: Note. Be sure to perform the plate voltage and line ad- just circult test before performing the blas voltage test. *The change superedes, C 3 December 1963. TAGO
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- TV _A_B_D_tube_tester_serv2_TM11 6625 274 35 _1960
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-197530.html



Marshall-9100-62-02-Schematic电路原理图.pdf