1、TM 11-5985-370-12 TECHNICAL MANUAL OPERATORS AND ORGANIZATIONAL MAINTENANCE MANUAL ANTENNA GROUP OE-303/GRC (NSN 5985-01-152-5845) HEADQUARTERS, DEPARTMENT OF THE ARMY19 JULY 1984 TM 11-5985-370-12 BEFORE LEAVING YOUR BASE, MAKE SURE YOU HAVE: ENOUGH WARNING SIGNS. EXTRA STREAMERS OR APPROVED MARKER
2、S. A SUPPLY OF SPECIAL ANCHORS TO USE IN THE TYPE OF SOIL YOU MAY FIND IN YOUR AREA OF OPERATIONS. EXTRA GUY ROPES OR APPROVED SUBSTITUTES. TM 11-5985-370-12 NEVER ERECT ANTENNA GROUP OE-303/GRC UNDER POWER LINES. IF YOU MUST ERECT THIS ANTENNA NEAR POWERLINES, POWER TOWERS, POWER POLES OR BUILDINGS
3、 WITH OVERHEAD POWER WIRES, FOLLOW THE RULE: “DOUBLE THE HEIGHT OF THE TALLEST THING IN THE AREA” EXAMPLE: If a powerline tower is 80 feet tall, (your antenna is 30 feet tall) DOUBLE 80 FEET to get a SAFE DISTANCE of 160 feet AWAY FROM the powerline tower. NEVER ATTEMPT TO ERECT THIS ANTENNA WITHOUT
4、 A TEAM OF TWO PERSONS AND THE NECESSARY HELP TO PROVIDE ADEQUATE CONTROL OF FOOT AND VEHICLE TRAFFIC IN THE AREA DURING ANTENNA ERECTION. AND NEVER ERECT OR OPERATE THIS ANTENNA DURING AN ELECTRICAL STORM. CLEARLY MARK THE ANTENNA AREA WITH SIGNS TO PREVENT PEOPLE AND VEHICLES FROM DRIVING THROUGH
5、THE AREA OR ATTEMPTING TO DRIVE UNDER THE ANTENNA ITSELF. IT MAY BE NECESSARY TO POST SIGNS IN SEVERAL LOCATIONS TO GET EFFECTIVE RESULTS. IT MAY EVEN BE NECESSARY TO POST A GUARD OR WATCH DURING CERTAIN TIMES (LIKE BLACKOUT OPERATIONS, BAD WEATHER, TROOP MOVEMENT). YOUR SUPERVISOR SHOULD CONSULT WI
6、TH THE UNIT SAFETY OFFICER TO MAKE SURE THAT ALL UNITS IN YOUR AREA ARE AWARE THAT YOUR LONG RANGE ANTENNA IS TAKING UP A LARGE AREA AND TO BE CAREFUL. MAKE SURE THE SOIL CAN SAFELY HOLD YOUR ANTENNA ANCHORS. IF THE SOIL IS LOOSE, MARSHY OR SANDY, IT MAY BE NECESSARY TO USE SPECIAL ANCHORS. USE OF S
7、PECIAL ANCHORS IS COVERED IN THIS MANUAL. WHEN OPERATING UNDER UNUSUAL CONDITIONS, IT WILL BE NECESSARY TO KEEP A SHARP EYE ON ALL ANCHORS UNTIL THESE CONDITIONS PASS. A TM 11-5985-370-12 CLEARLY MARK ALL GUY WIRES, GUY ROPES AND THE ANTENNA WIRES WITH FLAGS OR STREAMERS. STRIPS OF CLOTH MAKE GOOD S
8、TREAMERS. IF THE WEATHER IN YOUR AREA CAN CAUSE ICE TO FORM ON THE ANTENNA, GUY WIRES AND GUY ROPES, ADD EXTRA GUYS TO SUPPORT THE ANTENNA. CLEARLY MARK THE AREA WITH WARNING SIGNS LIKE “BEWARE OF FALLING ICE”. IF YOU SUSPECT THAT POWERLINES HAVE MADE ACCIDENTAL CON- TACT WITH YOUR ANTENNA - STOP OP
9、ERATION - TURN OFF THE EQUIPMENT- ROPE OFF OR HAVE SOME PERSON GUARD THE ANTENNA AREA - AND NOTIFY YOUR TEAM CHIEF. WHEN SELECTING A SITE FOR YOUR ANTENNA, KEEP IN MIND THAT YOU SHOULD SELECT GROUND WHICH WILL NOT ACCUMULATE WATER WHICH CAN REACH UP TO THE TRANSFORMERS USED AT EACH END OF THE ANTENN
10、A. THIS IS TO PREVENT A SHOCK HAZARD. FUMES OF TRICHLOROTRIFLOUROETHANE ARE POISONOUS. PROVIDE ADEQUATE VENTILATION WHENEVER YOU USE IT. DO NOT USE THIS SOLVENT NEAR HEAT OR OPEN FLAME. TRICHLOROTRIFLOUROETHANE WILL NOT BURN, BUT HEAT TURNS THE SOLVENT INTO POISONOUS AND IRRITATING FUMES. DO NOT BRE
11、ATHE THE FUMES OR VAPORS. THIS SOLVENT DISSOLVES NATURAL SKIN OILS. DO NOT GET THE SOLVENT ON YOUR SKIN. USE GLOVES, SLEEVES AND AN APRON WHICH THE SOLVENT CANNOT PENETRATE. IF THE SOLVENT IS TAKEN INTERNALLY, CONSULT A PHYSICIAN IMMEDIATELY. USE THIS SOLVENT ONLY ON THE METAL MAST SECTIONS, DO NOT
12、CLEAN THE TRAN- SFORMER HOUSINGS WITH THIS SOLVENT. B TM 11-5985-370-12 SAFETY STEPS TO FOLLOW IF SOMEONE IS THE VICTIM OF ELECTRICAL SHOCK DO NOT TRY TO PULL OR GRAB THE INDIVIDUAL IF POSSIBLE ,TURN OFF THE ELECTRICAL POWER IF YOU CANNOT TURN OFF THE ELECTRICAL POWER, PULL, PUSH, OR LIFT THE PERSON
13、 TO SAFETY USING A WOODEN POLE OR A ROPE OR SOME OTHER INSULATING MATERIAL SEND FOR HELP AS SOON AS POSSIBLE AFTER THE INJURED PERSON IS FREE OF CONTACT WITH THE SOURCE OF ELECTRICAL SHOCK, MOVE THE PERSON A SHORT DISTANCE AWAY AND IMMEDIATELY START ARTIFICIAL RESUSCITATION C TM 11-5985-370-12 HOW T
14、O USE THIS MANUAL This technical manual includes a cover index to assist you in locating the information you need to operate and maintain Antenna Group OE-303/GRC. In addition, this manual is also divided into chapters, sections and paragraphs which are numbered sequentially. Instructions on install
15、ation and use of this antenna equipment are presented in a detailed sequence. DO NOT ATTEMPT ANY SHORT CUTS in installing and using this antenna equipment. FOLLOW THE INSTRUCTIONS IN THIS MANUAL. This antenna equipment has been designed to work with certain radio sets in a certain frequency range. D
16、O NOT ATTEMPT TO REDESIGN THIS ANTENNA. Follow the specific DIMENSIONS and MEASUREMENTS in this manual. D TM 11-5985-370-12 TECHNICAL MANUAL NO. 11-5985-370-12 HEADQUARTERS DEPARTMENT OF THE ARMY Washington, DC, 19 July 1984 OPERATORS AND ORGANIZATIONAL MAINTENANCE MANUAL FOR ANTENNA GROUP OE-303/GR
17、C (NSN 5985-01-152-5845) REPORTING ERRORS AND RECOMMENDING IMPROVEMENTS You can help improve this manual. lf you find any mistakes or if you know of a way to improve the procedures, please let us know. Mail your letter, DA Form 2028 (Recommended Changes to Publications and Blank Forms), or DA Form 2
18、028-2 located in the back of this manual direct to: Commander, US Army Communications-Electronics Command and Fort Monmouth, ATTN: DRSEL- ME-MP Fort Monmouth, New Jersey 07703. In either case, a reply will be furnished direct to you. D CHAPTER 1. Section I. Il. Ill. CHAPTER 2. Section I. Il. III. IV
19、. V . V I . HOW TO USE THIS MANUAL INTRODUCTION General Information PAGE 1 - 1 Equipment Description Principles of Operation 1-10 1-17 OPERATING INSTRUCTIONS DescriPtion and Use of Operators Controls PMCS Operation Under Normal Conditions 2 - 1 2 - 4 2 - 9 2 - 1 3 2 - 2 5 2 - 3 5 Antenna Erection Or
20、ienting the Half -Rhombic Antenna Operation Under Unusual Conditions i TM 11-5985-370-12 CHAPTER Section I. CHAPTER Section I. 3. OPERATOR MAINTENANCE Troubleshooting 4. ORGANIZATIONAL MAINTENANCE 3-1 Repair Parts and TMDE Il. PMCS Ill. Troubleshooting 4-1 4-1 4-3 IV. Maintenance Procedures4-6 APPEN
21、DIX A Reference B Maintenance Allocation C Components of End ltem List D Additional Authorization List (Not Applicable) E Expendable Supplies and Materials List A - 1 B - 1 C - 1 D - 1 E - 1 i i TM 11-5985-370-12 CHAPTER 1 INTRODUCTION SECTION I. GENERAL INFORMATION 1-1. SCOPE This technical manual
22、covers Antenna Group OE-303/GRC. Instructions are given for: installation (2 person team) operation. troubleshooting. operator/crew maintenance. organizational maintenance. Antenna Group OE-303/GRC consists of 3 major items: Antenna AS-3490/GRC. Radio Frequency Cable Assembly CG-1889 C/U. Mast Assem
23、bly AB-1244A/GRC. 1-1 TM 11-5985-370-12 Antenna Group OE-303/GRC has the following characteristics: rugged. lightweight. directional radiation. no adjustments required. easy installation. It cannot be overemphasized that this antenna must be used with caution. It occupies a large area, Both foot and
24、 vehicular traffic must be controlled in the antenna area. The CAUTIONS and WARNINGS in the manual give you specific instructions on how to control traffic and to prevent accidents. 1-2 TM 11-5985-370-12 1-2. MAINTENANCE FORMS. RECORDS AND REPORTS Reports of Maintenance and Unsatisfactory Equipment.