OE-452_antenna_ serv_user_TM11-5985-391-12_1991.pdf
《OE-452_antenna_ serv_user_TM11-5985-391-12_1991.pdf》由会员分享,可在线阅读,更多相关《OE-452_antenna_ serv_user_TM11-5985-391-12_1991.pdf(158页珍藏版)》请在收音机爱好者资料库上搜索。
1、TM 11-5985-391-12 TECHNICAL MANUAL OPERATORS AND UNIT MAINTENANCE MANUAL EQUIPMENTPAGE DATA1-6 SETUPPAGE 2-3 PMCSPAGE 4-13 - STORAGE AND PAGE SHIPMENT4-43 MAC APP B SETUP REFER-APP ENCE CARDSF SPECIAL OPERATIONS RADIO ANTENNA KIT (SORAK) ANTENNA GROUP OE-452/PRC (NSN 5985-01-279-7942) Distribution a
2、uthorized to the Department of Defense and DOD contractors only for official use or for ad- ministrative or operational purposes. This determination was made on 15 April 1990. Other requests for this document will be referred to Commander, US Army Communications-Electronics Command and Fort Monmouth
3、, ATTN: AMSEL-LC-LM-LT, Fort Monmouth, NJ 07703-5000. DESTRUCTION NOTICE - Destroy by any method that will prevent disclosure of contents or reconstruction of the document. HEADQUARTERS, DEPARTMENT OF THE ARMY 1 JANUARY 1991 TM 11-5985-391-12 GUIDELINES FOR SORAK OPERATIONS Never erect the antenna d
4、irectly under power lines. If you must erect an antenna below a power line, power line pole, tower, or building with overhead power line connections, never put the antenna closer than two times the an- tenna height from the base of the power line, pole, tower, or building. Before erecting any SORAK
5、antenna, inspect all the parts making up the antenna kit. Do not deploy antenna if components are missing or damaged. When erecting the antenna, allow only team personnel in the erection area. Make sure the areas for antenna anchor and guy rope stakes are firm. If the ground is marshy or sandy, use
6、rocks, trees, or bushes to help secure the antenna. When selecting locations for antenna anchor and guy rope stakes, avoid traveled areas and roads. If you cannot avoid these areas, clearly mark guy ropes and antenna wires with the warning flags or signs supplied by your unit. In an emergency, use s
7、trips of white cloth as warning streamers. If you suspect that power lines nave made accidental contact with your antenna, stop operating, rope off the antenna area, and notify your superiors. Keep a sharp eye on your mast guy ropes and stakes, and antenna anchor stakes. Check them daily and immedia
8、tely before and after bad weather. DO NOT ERECT ANY ANTENNA DURING AN ELECTRICAL STORM. B TM 11-5985-391-12 SAFETY STEPS TO FOLLOW IF SOMEONE IS THE VICTIM OF ELECTRICAL SHOCK DO NOT TRY TO PULL OR GRAB THE INDIVIDUAL IF POSSIBLE, TURN OFF THE ELECTRICAL POWER IF YOU CANNOT TURN OFF THE ELECTRICAL P
9、OWER, PULL, PUSH, OR LIFT THE PERSON TO SAFETY USING A DRY WOODEN POLE OR A DRY ROPE OR SOME OTHER INSULATING MATERIAL SEND FOR HELP AS SOON AS POSSIBLE AFTER THE INJURED PERSON IS FREE OF CONTACT WITH THE SOURCE OF ELECTRICAL SHOCK, MOVE THE PERSON A SHORT DIS- TANCE AWAY AND IMMEDIATELY START ARTI
10、FICIAL RESUSCITATION C/(D blank) TM 11-5985-391-12 Technical ManualHEADQUARTERS DEPARTMENT OF THE ARMY No. 115985-391-12Washington, DC, 1 January 1991 Operators and Unit Maintenance Manual Special Operations Radio Antenna Kit (SORAK) Antenna Group OE-452/PRC (NSN 5985-01-279-7942) REPORTING ERRORS A
11、ND RECOMMENDING IMPROVEMENTS You can help improve this manual. If you find any mistakes, or if you know of a way to improve the procedures, please let us know. Mail your letter, DA Form 2028 (Recommended Changes to Publications and Blank Forms), or DA Form 2028-2 located in the back of this manual d
12、irect to: Commander, US Army Communications-Electronics Command and Fort Monmouth, ATTN: AMSEL-LC-LM-LT, Fort Monmouth, New Jersey 07703-5000. HOW TO USE THIS MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHAPTER 1 Section I Section II Section III CHAPTER 2 Section I Secti
13、on II Section III Section IV Section V CHAPTER 3 CHAPTER 4 Section I Section II Section III Section IV Section V Section VI INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Equipment Description .
14、 . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Principles of Operation . . . . . . . . . . . . . . . . . . OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . . . . Description and Use of Operators Controls. . . . . . . . . and Indicators Preventive Maintenance Checks. . . . . . . .
15、 . . . . . . . . . . . . and Services (PMCS) Operation Under Usual Conditions . . . . . . . . . . . . . . . . Operation Under Unusual Conditions. . . . . . . . . . . . . . Equipment Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OPERATOR MAINTENANCE INSTRUCTIONS. . ORGANIZATION
16、AL MAINTENANCE . . . . . . . . . Repair Parts, Special Tools, TMDE, . . . . . . . . . . . . . . . . and Support Equipment Service Upon Receipt . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preventive Maintenance Checks. . . . . . . . . . . . . . . . . . . . and Services (PMCS) Troubleshoot
17、ing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . Preparation for Storage or Shipment . . . . . . . . . . . . . . . Page ii 1-1 1-1 1-5 1-7 2-1 2-1 2-1 2-3 2-33 2-37 3-1 4-1 4-1 4-3 4-13 4-19 4-25 4-43 i T
18、M 11-5985-391-12 APPENDIX A APPENDIX B APPENDIX C APPENDIX D APPENDIX E APPENDIX F GLOSSARY INDEX References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance Allocation Chart. . . . . . . . . . . . . . . . . . . Components of End Item . . . . . . . . . . . . . . .
19、. . . . . . . . and Basic Issue Items Lists Additional Authorization List . . . . . . . . . . . . . . . . . . . Expendable and Durable Items List . . . . . . . . . . . . . . Antenna Deployment Reference Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page A-1 B-1 C-1 D-1 E-1 F-1 Glossary -1 Index -1 HOW TO USE THIS MANUAL This manual tells you how to set up and use the Antenna Group OE-452/PRC Special Operations Radio Antenna Kit
21、(SORAK). It also includes organizational level main- tenance instructions and data. The front cover index gives you a quick reference to important information that you will use most often. Warning pages are at the beginning of this manual. Study the warnings and always follow safety procedures when
22、installing, using, or maintaining the equipment. Units of measurement used in this manual are U.S. standard with metrics units in paren- theses. Read all information found at the start of each procedure. It includes important state- ments about the equipment and your safety. Paragraphs in this manua
23、l are numbered by chapter and order of appearance within a chapter. Indexes at the start of each chapter will help you find information quickly. ii TM 11-5985-391-12 CHAPTER 1 INTRODUCTION SubjectSectionPage General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I 1-
24、1 Equipment Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . II 1-5 Technical Principles of Operation . . . . . . . . . . . . . . . . . . . . . . .III 1-7 Section I. GENERAL INFORMATION Subject Para.Page Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- OE-452_antenna_ serv_user_TM11-5985-391-12_1991 OE 452 _antenna_ serv_user_TM11 5985 391 12 _1991
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


