1、VX-1700 Operating Manual Vertex Standard LMR, Inc. Table of Contents General .1 Front Panel Control conversely, counter-clock- wise rotation of this control allows progressively weaker signals to be heard. When a signal or noise breaks through the squelch “threshold,” the “” icon on the display will
2、 be illuminated. FRONT PANEL CONTROLS consult with a qualified service tech- nician when in doubt. Grounding for Electrical Safety Connect the rear panel ground lug to a good earth ground. For best performance, such a ground should consist of one or more ground rods 2.6 m (8 feet) long, connected to
3、 the transceiver via a low-inductance cable such as a heavy braided wire (the shield from surplus/discarded RG-213 type cable is ideal). The lead-in cable should be as short as possible. Do not use gas lines as a ground connection! Electrical Shock Prevention Be certain that all station wiring is pr
4、operly insulated so as to prevent short-circuits which could damage this trans- ceiver and/or accessories connected to it. Be sure to pro- tect power cables from damage due to abrasion by ensur- ing that they cannot be walked upon nor crushed under rolling chairs, etc. Never route power cables near
5、sharp metallic edges which might cut through protective insula- tion. Never spill liquids into this transceiver, and do not drop metallic objects into the transceiver enclosure. Electrical shock may result when you attempt to remove the object. Unsupervised children should be kept away from any elec
6、- trical apparatus such as the VX-1700 Transceiver and its accessories. INSTALLATION Antenna Precautions Always locate antennas such that they can never come in contact with outdoor power lines in the event of a cata- strophic antenna support or power line support structure failure. Ground the suppo
7、rt structure adequately, so as to dissipate energy absorbed during a lightning strike. In- stall appropriate lightning arrestors in the antenna lead-in and rotator cable (if used) according to the arrestors in- structions. In the event of an approaching electrical storm, discon- nect all antenna lea
8、d-in, rotator cables, and power cables completely from your station if the storm is not immedi- ately in your area. Do not allow disconnected cables to touch the case of your VX-1700 transceiver or accesso- ries, as lightning can easily jump from the cable to the circuitry of your transceiver via th
9、e case, causing irrepa- rable damage. If a lightning storm is in progress in your immediate area, do not attempt to disconnect the cables, as you could be killed instantly if lightning should strike your antenna structure or a nearby power line. If a vertical antenna is utilized, be certain that hum
10、ans and/or pets and farm animals are kept away both from the radiating element (to prevent electrical shock and RF ex- posure danger) and the ground system, in the event of an electrical storm. The buried radials of a ground-mounted vertical antenna can carry lethal voltages outward from the center
11、of the antenna in the event of a direct lightning strike. Heat and Ventilation To ensure long life of the components, be certain to pro- vide adequate ventilation around the cabinet of the VX- 1700. The cooling system of the transceiver must be free to draw cool air in from the bottom of the transce
12、iver and expel warm air from the rear of the transceiver. Do not install the transceiver on top of another heat-gen- erating device (such as a linear amplifier), and do not place equipment, books, or papers on top of the transceiver. Place the transceiver on a hard, flat, stable surface. Avoid heat-
13、 ing vents and window locations that could expose the trans- ceiver to excessive direct sunlight, especially in hot cli- mates. Page 6VX-1700 OPERATING MANUAL Electromagnetic Compatibility and RF Exposure If this transceiver is used with or in the vicinity of a com- puter or computer-driven accessor
14、ies, you may need to experiment with grounding and/or radio frequency inter- ference (RFI) suppression devices (such as ferrite cores) to minimize interference to your communications caused by energy leakage from the computer. Although there is negligible radio frequency (RF) leak- age from the VX-1
15、700 transceiver itself, its antenna sys- tem should be located as far away from humans and ani- mals as practicable, so as to avoid the possibility of shock due to accidental contact with the antenna or excessive long-term exposure to RF energy. Preliminary Inspection Inspect the transceiver visuall
16、y immediately upon open- ing the packing carton. Confirm that all controls and switches work freely, and inspect the cabinet for any dam- age. Gently shake the transceiver to verify that no inter- nal components have been shaken loose due to rough han- dling during shipping. If any evidence of damag
17、e is discovered, document it thor- oughly and contact the shipping company (or your local dealer, if the unit was purchased over-the-counter) so as to get instructions regarding the prompt resolution of the damage situation. Be certain to save the shipping carton, especially if there are any punctur
18、es or other evidence of damage incurred during shipping; if it is necessary to re- turn the unit for service or replacement, use the original packing materials but put the entire package inside an- other packing carton, so as to preserve the evidence of shipping damage for insurance purposes. INSTAL
19、LATION Page 7VX-1700 OPERATING MANUAL POWER REQUIREMENTS AND BASIC INSTALLATION DC Power Connections The VX-1700 transceiver is designed for operation from 13.8 Volts DC, negative ground, with the DC source be- ing capable of providing 25 Amperes of continuous cur- rent. For mobile applications, the
20、 fused (25-A) DC cable sup- plied with this transceiver may be used for making the power connections. Be absolutely certain to observe the proper polarity when making power connections: The RED DC power lead connects to the Positive (+) DC terminal; and The BLACK DC power lead connects to the Negati
21、ve () DC terminal. To minimize noise pickup, and to provide the best input voltage stability for your transceiver, we recommend you connect the DC cable directly to the vehicle battery, rather than to the ignition or accessory circuitry. Route the DC cable as far away from ignition cables as possibl
22、e, and cut off any extra cable (from the battery end) to minimize voltage drop. If the DC cable is not long enough, use #12 AWG (minimum) stranded, insulated wire to extend it. Be absolutely certain to solder the connections at the splice securely, and provide ample insulation for the soldered splic
23、e (heat shrink tubing plus black electrical tape work well). Use the following procedure to connect the DC cable: ? Before connecting the DC cable to the battery, mea- sure the voltage across the battery terminals with the engine running fast enough to show a charge. If the voltage is above 15 Volts
24、, the vehicles voltage regu- lator should be adjusted to reduce the charging volt- age below 14 Volts. ? With the radio end of the cable disconnected, connect the RED cable lead to the POSITIVE battery termi- nal, and the BLACK cable lead to the NEGATIVE battery terminal. Make certain that the batte
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Vertex_VX 1700 _series_USA_version_user
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf