1、1 Introduction This manual provides technical information necessary for servicing the VX-6000U UHF FM Transceiver. Servicing this equipment requires expertise in handling surface-mount chip components. Attempts by non-qualified persons to service this equipment may result in permanent damage not cov
2、ered by the warranty, and may be illegal in some countries. Two PCB layout diagrams are provided for each double-sided circuit board in the Transceiver. Each side of is referred to by the type of the majority of components installed on that side (“leaded” or “chip-only”). In most cases one side has
3、only chip components, and the other has either a mixture of both chip and leaded components (trimmers, coils, electrolyt- ic capacitors, ICs, etc.), or leaded components only. While we believe the technical information in this manual to be correct, VERTEX STANDARD assumes no liability for damage tha
4、t may occur as a result of typographical or other errors that may be present. Your cooperation in pointing out any inconsistencies in the technical information would be appreciated. 2003 VERTEX STANDARD CO., LTD. Printed in Japan. Service Manual VX-6000U UHF FM Transceiver Operating Manual Reprint .
5、1-1 Cloning.2-1 Specifications.2-2 Exploded View background noise will now be heard, and you may use this to set the VOLUME knob for the desired audio level. Press and hold the MON button more than 1/ 2 seconds to quiet the noise and resume normal (quiet) monitoring. Transmitting To transmit, wait u
6、ntil the “BUSY” indicator is off (the channel is not in use), and press the PTT (Push-To-Talk) switch on the side of the micro- phone (the “TX” indicator will appear or the “TX” indicator will glow red). While holding in the PTT switch, speak across the face of the microphone in a clear, normal voic
7、e level, and then release the PTT switch to receive. Selecting Groups and Channels H Press the UP (?) or DOWN (?) button (re- peatedly, if necessary) to select a different group of channels. H Turn the CHANNEL selector knob to select a different channel within the current group. Automatic Time-Out T
8、imer If the selected channel has been programmed for automatic time-out, you must limit the length of each transmission. While transmitting, a beep will sound five seconds before time-out. Another beep will sound just before the deadline; the “TX” in- dicator will disappear and transmission will cea
9、se soon thereafter. To resume transmitting, you must release the PTT and wait for the “penalty timer” to expire (if you press the PTT before this timer expires, the timer restarts, and you will have to wait another “penalty” period.) 1-4 POWER Operating Manual Reprint ADVANCED OPERATION Programmable
10、 Function Button (PF button) The VX-6000 includes the seven Programmable Function Buttons (PF button). The PF button functions can be customized, via programming by your VERTEX STANDARD dealer, to meet your communications/network requirements. Some features may require the purchase and in- stallatio
11、n of optional internal accessories. The possible PF button programming features are il- lustrated at the below, and their functions are explained on next page. For further details, contact your VERTEX STAN- DARD dealer. For future reference, check the box next to each function that has been assigned
12、 to the PF button on your particular radio, and keep it handy. 1.5 sec1.5 sec1.5 sec1.5 sec1.5 sec1.5 sec1.5 sec Functions Programmable Function Button (PF button) None SCAN (SCN) Dual Watch Call/Reset Talk-Around (TA) Alpha Numeric (A/N) DIMMER (DIM) Emergency (EMG) Horn Alert (HA) Home Channel (HO
13、M) Intercom (IC) Low Power (LOW) GRP UP GRP DWN CH UP CH DWN AUX A AUX B AUX C Public Address (PA) Monitor (MON) RCL Selectable Tone (ST) SP* Squelch Level (SQL) Compander Encryption* (OPT) * requires RMK-4000 * requires Encryption Unit 1-5 Operating Manual Reprint Channel Scan The Scanning feature
14、is used to monitor multiple signals programmed into the transceiver. While scanning, the transceiver will check each chan- nel for the presence of a signal, and will stop on a channel if a signal is present. To activate scanning: H Press the assigned PF button of the “Scan” mo- mentarily to activate
15、 scanning. H The scanner will search the channels, looking for active ones; it will pause each time it finds a channel on which someone is speaking. To stop scanning H Press the assigned PF button of the “Scan”. H Operation will revert to the channel to which the CHANNEL selector knob is set. Note:Y
16、our dealer may have programmed your radio to stay on one of the following chan- nels if you press the PTT switch during scanning pause: Current channel (“Talk Back”) “Last Busy” channel “Priority” channel “Home” channel Scan Start” channel Dual Watch The Dual Watch feature is similar to the Scan fea
17、- ture, except that only two channels are monitored: The current operating channel; and The “Priority” channel. To activate Dual Watch: H Press the assigned PF button of the “Dual Watch”. H The scanner will search the two channels; it will pause each time it finds a channel on which someone is speak
18、ing. To stop Dual Watch: H Press the assigned PF button of the “Dual Watch”. H Operation will revert to the channel to which the CHANNEL selector knob is set. ADVANCED OPERATION ARTS (Auto Range Transpond System) This system is designed to inform you when you and another ARTS-equipped station are wi
19、thin communication range. During ARTS operation, your radio automatically transmits for about 1 second every 25 (or 55) sec- onds (the interval is programmed by Dealer) in an attempt to Shake hands with the other station. If you move out of range for more than one min- utes, your radio senses that n
20、o signal has been received, a ringing beeper will sound. If you sub- sequently move back into range, as soon as the other station transmits, your beeper will sound. The PF Button Function The PF (Programmable Function) button can be programmed by the dealer to provide two of the other functions desc
21、ribed below. To activate the primary Accessory function, press the PF button momentarily. To access the second- ary Accessory function (which may include the Alarm), press and hold the PF button for 1.5 sec- onds or longer. Call/Reset When this feature is programmed and a selec- tive call has been r
22、eceived, momentarily press the assigned PF button of the “Call/Reset” to reset the flashing indicator and mute the receiver, oth- erwise press the assigned PF button of the “Call/ Reset” to sent your radios identification code (ANI) to the dispatcher. Talk-Around The feature causes the assigned PF b
23、utton of the “Talk-Around” to select simplex operation on semi-duplex channels: the transmit frequency becomes the same as the receive frequency (re- gardless of any programmed offset for the chan- nel). Note:This feature has no effect on simplex channels. After pressing the button, “-TAKARD-” is di
24、splayed on the LCD. Alpha Numeric Press the assigned PF button of the “Alpha Nu- meric” to switch the display between the Group/ Channel number, and the Group/ Channel name (alphanumeric). A tone will sound each time you switch between numerical and alphanumerical display. 1-6 Operating Manual Repri
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Vertex_VX 6000 U_serv
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf
4ad042e5gb10b9bac6239&690.
松下807图纸.png