1、 - 1 - No part of this manual may be copied, transcribed, translated or reproduced in any manner or form whatsoever, for commercial purposes, without obtaining prior written permission from Q-MAC Electronics Pty Ltd. However, limited copying is permitted for private use providing authorship is ackno
2、wledged. Copyright Q-MAC Electronics Pty Ltd, 2003. 142 Hasler Road Osborne Park, WA 6017 PO Box 1334 Osborne Park Business Centre, WA 6916 AUSTRALIA Australia: Phone 08 - 9242 2900, Fax 08 - 9242 3900 International: Phone +618 - 92242 2900, Fax +618 - 9242 3900 First Edition Print date: August 1996
3、 Second Edition Print date: February 1997 Third Edition Print date: October 2000 Author: Rod Macduff Literature Reference Number: TECH02C.PUB Part Number: QM1021 Additional Technical Support: Note that additional technical support is available to Q-MAC Dealers under the “Dealer Support” section of t
4、he Q-MAC website: . This site incorporates Technical Bulletins issued by Q-MAC, plus Technical Notes and Instructions in relation to specific products. - 2 - TABLE OF CONTENTS Section 1 Warnings & advice.4 Section 2 Introduction. 5 Section 3 Product specification. 6 Section 4 Mechanical assembly.7 S
5、ection 5 Functional overview.8 Section 6 Block diagrams Front panel.10 Microprocessor.11 Receiver/exciter.12 Synthesizers.13 Power amp & switching P.S.U.14 Section 7 Circuit description 7.1 Front panel PCB .15 7.2 RXMP PCB .16 7.3 PASW PCB .21 Section 8 Tables & diagrams Table 1. HF-90 micro port al
6、locations.24 Diagram 1. Serial link chain .25 Table 2. Diagram 2. Superhet. mixing scheme.26 Diagram 3. HF-90 Rx gain distribution.26 Table 3. HF-90 Tx low pass filters.27 Table 4. HF-90 connector pinouts.28 Diagram 4. Connector positions.30 Section 9 Maintenance 9.1 Disassembly & assembly.31 9.2 Re
7、placement of Microprocessor.32 9.3 Radio alignment.33 Section 10 Fault finding 10.1 No tools fault finding.36 Section 11 Diagnostic test sequence 11.1 Receiver test sequence.39 11.2 Transmitter test sequence .43 - 3 - Section 12 Test point overlays 12.1 RXMP test point voltages.45 HF-90 P.A. board a
8、lignment - position reference.46 Section 13 Software overview 13.1 Program description.47 13.2 Routine description (not frequency hopping).48 13.3 Software releases.50 Section 14 Hints & tips 14.1 Device removal.51 14.2 Servicing warnings.52 14.3 Servicing case histories.53 Section 15 Parts List 15.
9、1 Front panel PCB parts list (ISSUE N).60 15.2 RXMP PCB parts list (ISSUE V).61 15.3 PASW PCB parts list (ISSUE Q) .67 Section 16 PCB overlays Front panel top overlay - issue N (designators).72 Front panel top overlay - issue N (component values).73 RXMP top overlay - issue V (designators).74 RXMP t
10、op overlay - issue V (component values).75 PASW top overlay - issue Q (designators).76 PASW top overlay - issue Q (component values).77 Section 17 Schematic diagrams HF-90 display (90000).79 HF-90 I.F. strip, micro section & synth (90003).80 HF-90 P.A. & power supply (90002).81 Section 18 External c
11、onnectors.82 Section 19 Device pinouts & codes Device pinouts.84 19.1 SMD capacitor codes.85 - 4 - 1. On no account should the unit be connected directly to 110volt or 240volt AC mains power. Serious damage or personal injury may result. 2. An approved 12volt or 24volt power supply or battery should
12、 be used. The supply should be capable of sourcing peak currents up to 10ampere. Failure to comply with this rating will result in severe distortion on transmissions. Please note that some power supplies labeled as 10ampere peak are not adequate as the voltage collapses towards the peaks. 3. Use onl
13、y the approved power cable for installation. Use of thinner conductors or extensions will result in severe distortion on transmissions. 4. The system performance is generally only as good as the antenna and ground system will allow. If unbalanced antennas are being used eg. whips, end-fed broadbands
14、 etc, then it is vital to obtain a good low impedance ground connection either to a vehicle body, a moist patch of ground or a metal fence with rust removed at the point of connection. 5. The HF-90 is extremely small. When transmitting, the heatsink and extrusion may get very hot. Under some circums
15、tances it may be possible to get burned by touching the heatsink. The radio has been designed and tested to cope with elevated temperatures. However the user should endeavour to allow free circulation of air around the radio. 6. In order to achieve the high output power, an internal power convertor
16、is used to supply +55volt to the final amplifier on transmit. The energy stored by this supply is quite high (2.2joules) and it is wise to WAIT FOR A FULL MINUTE after transmitting prior to doing any service work on the PASW printed circuit board. 7. Radio Frequency Field Exposure: The HF-90 Package
17、s generate high radio frequency fields. Their antennas are marked with a safe working distance in accordance with required Standards. This should be observed. 8. This device complies with Part 90 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interfer
18、ence. 1. WARNINGS & ADVICE ! ! - 5 - 2. INTRODUCTION The HF-90 Compact Transceiver breaks new ground in the following areas: Size: The volume of the transceiver is approximately one litre. This is less than a tenth of comparable products. On initial inspection it is often mistaken for a VHF/UHF set.