Vertex_VX-4500_4600_UHF_serv.pdf
《Vertex_VX-4500_4600_UHF_serv.pdf》由会员分享,可在线阅读,更多相关《Vertex_VX-4500_4600_UHF_serv.pdf(45页珍藏版)》请在收音机爱好者资料库上搜索。
1、1VX-4500/-4600 Series UHF FM Transceiver Service Manual Introduction This manual provides the technical information necessary for servicing the VX-4500/-4600 Series Mobile Transceiver. Servicing this equipment requires expertise in handing surface-mount chip components. Attempts by non-qualified per
2、sons to service this equipment may result in permanent damage not covered by the warranty, and may be illegal in some countries. Two PCB layout diagrams are provided for each double-sided board in this transceiver. Each side of the board is referred to by the type of the majority of components insta
3、lled on that side (“Side A” or “Side B”). In most cases one side has only chip components (surface-mount devices), and the other has either a mixture of both chip and leaded components (trimmers, coils, electrolytic capacitors, ICs, etc.), or leaded components only. As described in the pages to foll
4、ow, the advanced microprocessor design of the VX-4500/-4600 allows a complete alignment of this transceiver to be performed without opening the case of the radio; all adjustments can be performed from the personal computer, using with the Vertex Standard FIF-12 USB Programming Interface and CE115 So
5、ftware. While we believe the information in this manual to be correct, Vertex Standard assumes no liability for damage that may occur as a result of typographical or other errors that may be present. Your cooperation in pointing out any inconsistencies in the technical information would be appreciat
6、ed. 2013 Vertex Standard LMR, Inc. EC093U90G UHF FM Transceiver VX-4500 Series VX-4600 Series Service Manual VX-4600 SeriesVX-4500 Series Specifications . 2 DSUB 15-pin Accessory Connector . 3 Exploded View programmed via the CE115 program- mer) at 600-ohm. Pin 2: AF OUT (ANALOG OUTPUT) Low-level re
7、ceiver output. Peak signal level is 10 dBm at 600-ohm. Pin 3: AF GND Ground for all logic levels and power supply return. Pin 4: DC OUT (13.6 V DC OUTPUT) Switched 13.6V output for supplying power to an acces- sory. Maximum output current is 1 A. Pin 5: RSSI (ANALOG OUTPUT) A DC voltage proportional
8、 to the strength of the signal cur- rently being received (Receiver Signal Strength Indicator) is provided on this pin. This low impedance output is gererated by the receiver IF sub-system and bufferd by an internal op-amp. Typical output voltages are 1 V (No Sig- nal Input) through 2.5 V (50 dB Sig
9、nal Input). Pin 6: EXT PTT Shorting this port to ground causes the transceiver to be placed in the Transmit mode, while opening the connection to this port returns the transceiver to the Receive mode. Opening voltage is 5 V, closed current approx. 5 mA. Pin 7: TRX This port is intended for controlli
10、ng an external TX/RX switching circuit. When the transceiver is placed in the Re- ceiver mode, this port is 5 V. When the transceiver is placed in the Transmit mode, this port reduce to 0 V. This port is open drain output which can sink approx. 50 mA when active. Pin 8: ING (IGNITION SENSE FEATURE)
11、The VX-4500/-4600 may be automatically be switched to the STND-BY mode when the vehicles ignition key is turned on. Maximum current is 20 mA. Pin 9 - 12: ACC1 - ACC4 (ACCESSORY PORT) These port features can be programmed via the CE115 pro- grammer. Each port is open drain output which can sink appro
12、x. 50 mA when active. Max. output 16 V. When the input is selected, it becomes active between 2 V and 16 V. Pin 13: ACC5 (ACCESSORY PORT) The port 5 is available to set only for Output function, and active logic is opposite side against the Port 1 4. Max. output 5 V, closed current approx. 1 mA (CMO
13、S out- put). Pin 14: ACC6 (ACCESSORY PORT) The port 6 is available to set only for Input function, and active logic is opposite side against the Port 1 4. Max. input 5 V (CMOS input). Pin 15: GND Chassis ground 4VX-4500/-4600 Series UHF FM Transceiver Service Manual Exploded View realignment should
14、not be done until after the faulty component has been replaced. We recommend that servicing be performed only by authorized Vertex Standard service technicians who are experienced with the circuitry and fully equipped for repair and alignment. There- fore, if a fault is suspected, contact the dealer
15、 from whom the transceiver was purchased for instructions regarding repair. Authorized Vertex Standard service technicians realign all cir- cuits and make complete performance checks to ensure com- pliance with factory specifications after replacing any faulty components. Those who do undertake any
16、of the following align- ments are cautioned to proceed at their own risk. Problems caused by unauthorized attempts at realignment are not cov- ered by the warranty policy. Also, Vertex Standard must re- serve the right to change circuits and alignment procedures in the interest of improved performan
17、ce, without notifying own- ers. Under no circumstances should any alignment be attempt- ed unless the normal function and operation of the transceiver are clearly understood, the cause of the malfunction has been clearly pinpointed and any faulty components replaced, and the need for realignment det
18、ermined to be absolutely necessary. The following test equipment (and thorough familiarity with its correct use) is necessary for complete realignment. Correction of problems caused by misalignment resulting from use of im- proper test equipment is not covered under the warranty policy. While most s
19、teps do not require all of the equipment listed, the interactions of some adjustments may require that more com- plex adjustments be performed afterwards. Do not attempt to perform only a single step unless it is clearly isolated electrical- ly from all other steps. Have all test equipment ready bef
20、ore beginning, and follow all of the steps in a section in the order presented. Required Test Equipment ? Radio Tester with calibrated output level at 1 GHz ? In-line Wattmeter with 5% accuracy at 1 GHz ? 50-ohm, 50-W RF Dummy Load ? Regulated DC Power Supply (standard 13.6V DC, 15A) ? Frequency Cou
21、nter: 0.2 ppm accuracy at 1 GHz ? AF Signal Generator ? AC Voltmeter ? DC Voltmeter ? UHF Sampling Coupler ? IBM PC/compatible Computer with Microsoft Windows 2000, XP, Vista or Windows7 ? Vertex Standard CE115 PC Programming Software ? Vertex Standard FIF-12 USB Programming Interface and CT-104A, C
22、T-106, or CT-171 PC Programming Cable ? Vertex FRB-6 Tuning Interface Box and CT-159 Connec- tion Cable Alignment Preparation & Precautions A 50-ohm RF Dummy load and in-line wattmeter must be con- nected to the main antenna jack in all procedures that call for transmission, except where specified o
23、therwise. Correct align- ment is not possible with an antenna. Beacuse of the BTL (Bridged Trans Less) Amplifier circuit used in the VX-4500/-4600, do not connect eather side of the speak- er leads to chassis “ground”. After completing one step, read the following step to determine whether the same
24、test equipment will be required. If not, re- move the test equipment (except dummy load and wattmeter, if connected) before proceeding. Correct alignment requires that the ambient temperature be the same as that of the transceiver and test equipment, and that this temperature be held constant betwee