1、EVX-5300/-5400 UHF Service Manual1 Introduction This manual provides technical information necessary for servicing the EVX-5300/-5400 UHF Digital/Analog Mobile Trans- ceiver. Servicing this equipment requires expertise in handling surface-mount chip components. Attempts by non-qualiied persons to se
2、rvice this equipment may result in permanent damage not covered by the warranty, and may be illegal in some countries. Two PCB layout diagrams are provided for each double-sided circuit board in the transceiver. Each side of is referred to by the type of the majority of components installed on that
3、side (“leaded” or “chip-only”). In most cases one side has only chip com- ponents, and the other has either a mixture of both chip and leaded components (trimmers, coils, electrolytic capacitors, ICs, etc.), or leaded components only. As described in the pages to follow, the advanced microprocessor
4、design of the EVX-5300/-5400 allows a complete alignment of this transceiver to be performed without opening the case of the radio; all adjustments can be performed from the personal computer, using with the Vertex Standard FIF-12 USB Programming Interface and CE142 Software. While we believe the te
5、chnical information in this manual to be correct, Vertex Standard assumes no liability for damage that may occur as a result of typographical or other errors that may be present. Your cooperation in pointing out any inconsistencies in the technical information would be appreciated. Important Note Th
6、is transceiver is assembled using Pb (lead) free solder, based on the RoHS speciication. Only lead-free solder (Alloy Composition: Sn-3.0Ag-0.5Cu) should be used for repairs performed on this apparatus. The solder stated above utilizes the alloy composition required for compliance with the lead-free
7、 speciication, and any solder with the above alloy composition may be used. UHF Digital/Analog Mobile Transceiver EVX-5300/-5400 Service Manual Vertex Standard LMR, Inc. 2014 Vertex Standard LMR, Inc. EC114U90E Contents Speciications USA/EXP Models .2 EU Model .3 DSUB 15-pin Accessory Connector .4 E
8、xploded View programmed via the CE142 programmer) at 600-ohm. Pin 2: AF OUT (Analog Output) Low-level receiver output. Peak signal level is 10 dBm at 600-ohm. Pin 3: AF GND Ground for all logic levels and power supply return. Pin 4: DC OUT (13.6 V DC Output) Switched 13.6V output for supplying power
9、 to an acces- sory. Maximum output current is 1 A. Pin 5: RSSI (Analog Output) A DC voltage proportional to the strength of the signal currently being received (Receiver Signal Strength Indica- tor) is provided on this pin. This low impedance output is generated by the receiver IF sub-system and buf
10、fered by an internal op-amp. Typical output voltages are 0.1 V ( No Signal Input) through 2.0 V (50 dB Signal Input). Pin 6: EXT PTT Shorting this port to ground causes the transceiver to be placed in the Transmit mode, while opening the connec- tion to this port returns the transceiver to the Recei
11、ve mode. Opening voltage is 5 V, closed current approx. 5 mA. Pin 7: TRX This port is intended for controlling an external TX/RX switching circuit. When the transceiver is placed in the Receiver mode, this port is 5 V. When the transceiver is placed in the Transmit mode, this port reduce to 0 V. Thi
12、s port is open drain output which can sink approx. 50 mA when active. Pin 8: IGN (Ignition Sense feature) The EVX-5300/-5400 may be automatically be switched to the STND-BY mode when the vehicles ignition key is turned on. Maximum current is 20 mA. Pin 9-12: ACC1 - ACC4 (Accessory Port) These port f
13、eatures can be programmed via the CE142 programmer. Each port is open drain output which can sink approx. 50 mA when active. Max. output 16 V. When the input is selected, it becomes active between 2 V and 16 V. Pin 13: ACC5 (Accessory Port) The port 5 is available to set only for Output function, an
14、d active logic is opposite side against the Port 1 4. Max. output 5 V, closed current approx. 1 mA (CMOS output). Pin 14: ACC6 (Accessory Port) The port 6 is available to set only for Input function, and active logic is opposite side against the Port 1 4. Max. input 5 V (CMOS input). Pin 15: GND Cha
15、ssis ground EVX-5300/-5400 UHF Service Manual5 Exploded View realignment should not be done un- til after the faulty component has been replaced. We recommend that servicing be performed only by autho- rized Vertex Standard service technicians who are experi- enced with the circuitry and fully equip
16、ped for repair and alignment. Therefore, if a fault is suspected, contact the deal- er from whom the transceiver was purchased for instructions regarding repair. Authorized Vertex Standard service techni- cians realign all circuits and make complete performance checks to ensure compliance with facto
17、ry speciications after replacing any faulty components. Those who do undertake any of the following alignments are cautioned to proceed at their own risk. Problems caused by unauthorized attempts at realignment are not covered by the warranty policy. Also, Vertex Standard must reserve the right to c
18、hange circuits and alignment procedures in the interest of improved perfor- mance, without notifying owners. Under no circumstances should any alignment be attempted unless the normal func- tion and operation of the transceiver are clearly understood, the cause of the malfunction has been clearly pi
19、npointed and any faulty components replaced, and the need for realignment determined to be absolutely necessary. The following test equipment (and thorough familiarity with its correct use) is necessary for complete realignment. Correction of problems caused by misalignment resulting from use of imp
20、roper test equipment is not covered under the warranty policy. While most steps do not require all of the equipment listed, the inter- actions of some adjustments may require that more complex adjustments be performed afterwards. Do not attempt to per- form only a single step unless it is clearly is
21、olated electrically from all other steps. Have all test equipment ready before beginning, and follow all of the steps in a section in the order presented. Alignment Required Test Equipment r Radio Tester with calibrated output level at 600 MHz r In-line Wattmeter with 5% accuracy at 600 MHz r 50-ohm
22、, 100 W RF Dummy Load r Regulated DC Power Supply (standard 13.6 VDC, 15 A) r Frequency Counter: 0.2 ppm accuracy at 600 MHz r AF Signal Generator r AC Voltmeter r DC Voltmeter r UHF Sampling Coupler r IBM PC/Compatible Computer with Microsoft Win- dows 2000, XP, Vista, or 7 r Vertex Standard CE142
23、PC Programming Software r Vertex Standard FIF-12 USB Programming Interface and CT-104A or CT-171 PC Programming Cable r Vertex Standard FRB-6 Tuning Interface Box and CT-159 Connection Cable Alignment Preparation only one step proce- dure. 6. Click the “OK” button, then the data will be saved and th
24、e alignment is inished. Alignment EVX-5300/-5400 UHF Service Manual17 5. tx power This parameter is to align the “High Power”, “Low3 Power”, and “Low2 Power” for the selected channel. 1. Click the “TX Power (High Pwr / Low3 Pwr / Low2 Pwr)” but- ton to open the “TX Power Alignment” window. 2. Click