Vertex_VX-1400_user.pdf
《Vertex_VX-1400_user.pdf》由会员分享,可在线阅读,更多相关《Vertex_VX-1400_user.pdf(56页珍藏版)》请在收音机爱好者资料库上搜索。
1、VX-1400 OPERATING MANUAL Vertex Standard LMR, Inc. 4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan MH-67A8J Hand Microphone is optional. VX-1400 Quick Reference Guide .1 Button Overview / Reset Procedure.2 General .3 Front Panel Control consult with a qualified service technician when in doubt. G
2、rounding for Electrical Safety Connect the rear panel ground lug to a good earth ground. For best performance, such a ground should consist of one or more ground rods 2.6 m (8 feet) long, connected to the transceiver via a low-inductance cable such as a heavy braided wire (the shield from sur- plus/
3、discarded RG-213 type cable is ideal). The lead-in cable should be as short as pos- sible. Do not use gas lines as a ground connection! Electrical Shock Prevention Be certain that all station wiring is properly insulated so as to prevent short-circuits which could damage this transceiver and/or acce
4、ssories connected to it. Be sure to protect power cables from damage due to abrasion by ensuring that they cannot be walked upon nor crushed under rolling chairs, etc. Never route power cables near sharp metallic edges which might cut through protective insulation. Never spill liquids into this tran
5、sceiver, and do not drop metallic objects into the trans- ceiver enclosure. Electrical shock may result when you attempt to remove the object. Unsupervised children should be kept away from any electrical apparatus such as the VX- 1400 Transceiver and its accessories. INSTALLATION VX-1400 OPERATING
6、MANUAL8 Antenna Precautions Always locate antennas such that they can never come in contact with outdoor power lines in the event of a catastrophic antenna support or power line support structure failure. Ground the support structure adequately, so as to dissipate energy absorbed during a light- nin
7、g strike. Install appropriate lightning arrestors in the antenna lead-in and rotator cable (if used) according to the arrestors instructions. In the event of an approaching electrical storm, disconnect all antenna lead-in, rotator cables, and power cables completely from your station if the storm is
8、 not immediately in your area. Do not allow disconnected cables to touch the case of your VX-1400 trans- ceiver or accessories, as lightning can easily jump from the cable to the circuitry of your transceiver via the case, causing irreparable damage. If a lightning storm is in progress in your immed
9、iate area, do not attempt to disconnect the cables, as you could be killed in- stantly if lightning should strike your antenna structure or a nearby power line. If a vertical antenna is utilized, be certain that humans and/or pets and farm animals are kept away both from the radiating element (to pr
10、event electrical shock and RF exposure danger) and the ground system, in the event of an electrical storm. The buried radials of a ground-mounted vertical antenna can carry lethal voltages outward from the center of the antenna in the event of a direct lightning strike. Heat and Ventilation To ensur
11、e long life of the components, be certain to provide adequate ventilation around the cabinet of the VX-1400. The cooling system of the transceiver must be free to draw cool air in from the bottom of the transceiver and expel warm air from the rear of the transceiver. Do not install the transceiver o
12、n top of another heat-generating device (such as a linear amplifier), and do not place equipment, books, or papers on top of the transceiver. Place the transceiver on a hard, flat, stable surface. Avoid heating vents and window locations that could expose the transceiver to excessive direct sunlight
13、, especially in hot climates. INSTALLATION SAFETY PRECAUTIONS 9VX-1400 OPERATING MANUAL Electromagnetic Compatibility and RF Exposure If this transceiver is used with or in the vicinity of a computer or computer-driven acces- sories, you may need to experiment with grounding and/or radio frequency i
14、nterference (RFI) suppression devices (such as ferrite cores) to minimize interference to your commu- nications caused by energy leakage from the computer. Although there is negligible radio frequency (RF) leakage from the VX-1400 transceiver itself, its antenna system should be located as far away
15、from humans and animals as prac- ticable, so as to avoid the possibility of shock due to accidental contact with the antenna or excessive long-term exposure to RF energy. Preliminary Inspection Inspect the transceiver visually immediately upon opening the packing carton. Confirm that all controls an
16、d switches work freely, and inspect the cabinet for any damage. Gently shake the transceiver to verify that no internal components have been shaken loose due to rough handling during shipping. If any evidence of damage is discovered, document it thoroughly and contact the shipping company (or your l
17、ocal dealer, if the unit was purchased over-the-counter) so as to get instructions regarding the prompt resolution of the damage situation. Be certain to save the shipping carton, especially if there are any punctures or other evidence of damage incurred during shipping; if it is necessary to return
18、 the unit for service or replacement, use the original packing materials but put the entire package inside another packing car- ton, so as to preserve the evidence of shipping damage for insurance purposes. INSTALLATION SAFETY PRECAUTIONS VX-1400 OPERATING MANUAL10 POWER REQUIREMENTS AND BASIC INSTA
19、LLATION DC Power Connections The VX-1400 transceiver is designed for operation from 13.8 Volts DC, negative ground, with the DC source being capable of providing 23 Amperes of continuous current. For mobile applications, the fused (25-A) DC cable supplied with this transceiver may be used for making
20、 the power connections. Be absolutely certain to observe the proper polar- ity when making power connections: The RED DC power lead connects to the Positive (+) DC terminal; and the BLACK DC power lead connects to the Negative () DC terminal. To minimize noise pickup, and to provide the best input v
21、oltage stability for your trans- ceiver, we recommend you connect the DC cable directly to the vehicle battery, rather than to the ignition or accessory circuitry. Route the DC cable as far away from ignition cables as possible, and cut off any extra cable (from the battery end) to minimize voltage
22、drop. If the DC cable is not long enough, use #12 AWG (minimum) stranded, insulated wire to extend it. Be absolutely certain to solder the connections at the splice securely, and provide ample insulation for the soldered splice (heat shrink tubing plus black electrical tape work well). INSTALLATION
23、12V Battery Cigarette Lighter Plug Fuse Box REDBLACK VX-1400 FUSE: 25A When disconnecting the DC cable from the transceiver, pull the DC cable while pressing here. 11VX-1400 OPERATING MANUAL Use the following procedure to connect the DC cable: ?Before connecting the DC cable to the battery, measure
24、the voltage across the battery terminals with the engine running fast enough to show a charge. If the voltage is above 15 Volts, the vehicles voltage regulator should be adjusted to reduce the charg- ing voltage below 14 Volts. ?With the radio end of the cable disconnected, connect the RED cable lea