1、EK895/EK896 Digital VLF-HF Receivers For all shortwave applications from 10 kHz to 30 MHz Data sheet Compact DSP-based receivers for the following applications: Radiomonitoring and radio detection Radiocommunications Search operation, DF systems Frontend for HF intelligence tasks Digital signal proc
2、essing (DSP) for convenient and versatile operation Two models: EK895 half-rack receiver EK896 search receiver Realtime remote control or master-slave mode Tried and tested system concept Excellent price/performance ratio Extremely reliable operation under harsh environmental and EMC conditions EK89
3、5/EK896 Digital VLF-HF Receivers EK895/EK896 digital VLF-HF receivers Special features Excellent large-signal behavior, very good intercept points High resolution of tuning frequency down to 1 Hz Fast and low-noise synthesizer Demodulators for AM, CW, LSB, USB, ISB, FM, FSK, AFSK and FAX included in
4、 basic configuration 13 bandwidths from 150 Hz to 8 kHz (quasi-continuous on request) RF preamplifier, switchable (noise figure 8kT0) Double notch filter Noise blanker DATA LINK reception (option) Passband tuning Syllabic squelch Special RTTY (FSK/AFSK) mark and space filters, matched to the selecte
5、d shift Digital data output Maximum input voltage protection up to 100 V EMF Control interface fully complying with international standards Low power consumption 0 dB (0 dB) at 10 % spacing from the center frequency Switch on/off by remote control Input voltage protection of 00 V EMF Rear view of th
6、e EK895 EK895/EK896 Digital VLF-HF Receivers 7 The FK896D digitally tuned RF selector is recommended for use in en- vironments with strong RF interference (collocation problems). It improves input selection by automatically tracking the receive frequency and, at the same time, considerably increases
7、 input-voltage protection (overload protection). GM893 broadband IF output (option) The optional broadband output (plug-in module) supplies a 1 MHz output signal at the first IF of 1. MHz (relative to a receive frequency of 500 kHz). To pre- vent impairment of the receiver sensitiv- ity of the main
8、channel (message chan- nel), the path to the broadband chan- nel is decoupled by approx. 10 dB. For broadband spectrum analysis, a spec- trum display can be connected to this broadband output. Digital data output For further digital signal processing of the received signal, a separate digital IF int
9、erface (connector X 69 at rear) is available, delivering the digital DATA, CLOCK FRAME outputs (0 Hz to 0 kHz, sampling rate 100 ksps). DATA LINK option If DATA LINK operation (MIL-STD-188- 03-1A) is required, special receiver versions are available. 1.44 MHz IF output, unregulated (option) For conn
10、ecting and operating an exter- nal IF spectrum display, an unregulated IF output at 1. MHz is available. This option uses the HF unit (model .03) and has to be ordered along with the basic receiver. Operating concept The EK890 family has a suitable operating mode for every application (see also page
11、 8). The remote-control interface is configured to the RS-85 standard and is bus-compatible for system operation. Users who want to control their radiomonitoring system from the receiver front panel rather than from a computer can use the receivers of the EK890 family as a master re- ceiver or insta
12、ll the GB899 remote control unit. The softkey-menu operator interface provides the ergonomical advantage of clean front panel layout as well as ac- cess to a large number of setting param- eters. When you insert extension mod- ules, they are automatically detected and incorporated in the software BI
13、T and the menu system. The clearcut operat- ing concept of the EK890 family has five menu levels which allow 50 logi- cally structured operating routines to be called up by softkeys. In spite of the mul- titude of functions, operation is highly convenient, e.g. each type of modula- tion is assigned
14、a default setting with all relevant parameters, which can also be individually programmed. The table shows all possible settings down to the second menu level. For fast access to the setting param- eters, the EK896 has 1 additional hardkeys, e.g. for standard types of mod- ulation, bandwidth variati
15、on, etc. Main menu: MOD GAIN BW SCA MORE Second menu level MODDemodulation modes MORE: for further modes AM CW LSB USB MORE GAINControl modes Auto, manual, auto+manual, auto+digital MORE: fast or slow control AGC MGC A+M A+D MORE BWBandwidthBW BW SCAScan mode Frequency sweep, channel sweep (any sequ
16、ence), channel sweep (incremental), stop or continue sweep, program sweep FRQ CHP CHS S/C PRO MORE: M/S SYS SPEC CHM MEM M/SMaster-slave operation Address slave (indicate slave address, e.g. 6), read out or vary slave settings ADR 62 GET PUT SYSSystem status Read out firmware version, built-in optio
17、ns, error messages; start self-test; MORE: total reset VERS OPT CM BIT MORE SPECSpecial functions Rotary knob: step size on/off; level setting for threshold-controlled external switching sig- nal; show serial interface setting; switch to remote control; default settings on/off KNOB LEV SER REM DEF C
18、HMChannel memory parameters Channel memory indication and channel-specific parameter variation without interrupting reception MOD GAIN BW THLD MEMChannel memory operations Clear all memory, clear certain memory, store to certain memory, use next free memory CLA CLCH STCH STO 8 EK895/EK896 Digital VL
19、F-HF Receivers Control concepts of the EK895/EK896 digital VLF-HF receivers Certified Quality System ISO 9001 DQS REG. NO 1954 QM Certified Environmental System ISO 14001 DQS REG. NO 1954 UM AQAP-110 Audit report GP Q2-NO 96.07 Certified Quality System AS 9100 DQS REG. NO 1954 AS Certified Quality S