Anritsu MS4661_4662 电路图.pdf
《Anritsu MS4661_4662 电路图.pdf》由会员分享,可在线阅读,更多相关《Anritsu MS4661_4662 电路图.pdf(5页珍藏版)》请在收音机爱好者资料库上搜索。
1、For product ordering information, see pages 4-213 NETWORK ANALYZERS 3 For Measuring Transmission/Reflection and S-Parameter NETWORK ANALYZER MS4661A/E, MS4662A 100 kHz to 3 GHz PTA GPIB The MS4661A/E include a built-in transmission/reflection measure- ment test set (bridge), making them ideal for me
2、asuring antennas and passive devices (filters, attenuators, switches, cables) where the input and output impedances are nearly equal. The MS4662A also has an S-parameter test set. In addition to measuring active devices with dif- ferent input and output characteristics (such as amplifiers), it mea-
3、sures forward and reverse direction characteristics with a single con- nection. You can choose the model best suited to your application. The MS4661A and MS4662A has color LCD displays, while the MS4661E has an EL display (monochrome). The high-speed synthesizer and DSP (digital signal processor) pe
4、r- mit measurements at 400 s/point (or 600 s/point using two-port cal- ibration), with sweep times approximating real-time measurement. Post-measurement data analysis is facilitated by unique functions such as limit tests, 3 dB bandwidth searches, and ripple searches for device evaluation and pass/f
5、ail identification. With PTA (Personal Test Automation) capability as standard, it is easy to configure ATE (Automated Test Equipment) systems. Features Built-in transmission/reflection measurement, and S-parameter test set Full range of limit test functions for real-time pass/fail testing One-touch
6、 measurement of each characteristic using target data search function Time domain analysis Application examples Measurement of cable fault locations Time-domain function permits measurement of distances to cable faults and impedance mismatch points. Simultaneous measurement of amplifier forward/reve
7、rse direction transmission (MS4662A) The S-parameter test set in the MS4662A allows you simultaneous measurement of forward and reverse direction device characteristics. Custom-made product RadioFans.CN 收音机爱 好者资料库 NETWORK ANALYZERS For product ordering information, see pages 4-7. Measurement Frequen
8、cy Measurement items Display Display format Resolution Frequency accuracy Range Internal reference oscillator S parameter: S11, S21 Level characteristics: R, TA, TB Group delay characteristics: GPDLY (any aperture) Time domain characteristics: displays impulse and step response of above characterist
9、ics S11: LOG MAG, PHASE, LIN MAG, REAL IMAG, POLAR (M/P), VSWR, IMPD (ZPHASE, Q/D, RS/CS, LS, R+jX), ADMT (YPHASE, Q/D, RP/CP, LP, G+jB) S21: LOG MAG, PHASE, LIN MAG, REAL IMAG, POLAR (M/P), HSDLY GPDLY: REAL LEVEL: LOG MAG Time domain (band pass, low pass, impulse/step response): LOG MAG, PHASE, LI
10、N MAG, REAL, IMAG S parameter: S11, S21, S12, S22 Level characteristics: R, TA, TB Time domain characteristics: displays impulse and step response of above characteristics S11/S22: LOG MAG, PHASE, LIN MAG, REAL IMAG, POLAR (M/P), VSWR, IMPD (ZPHASE, Q/D, RS/CS, LS, R+jX), ADMT (YPHASE, Q/D, RP/CP, L
11、P, G+jB) S21/S12: LOG MAG, PHASE, LIN MAG, REAL IMAG, POLAR (M/P), HSDLY LEVEL: LOG MAG Time domain (band pass, low pass, impulse/step response): LOG MAG, PHASE, LIN MAG, REAL, IMAG Model Filter pass/fail judgment using limit tests The segment limit test permits pass/fail testing for complex charac-
12、 teristics with subtle fluctuations in slope not detected as ripples. Filter analysis using target data search This function is useful in filter 3 dB bandwidth measurements and ripple searches. Specifications MS4661A/E 1 to 2 screens (front/back, split) 100 kHz to 3 GHz Minimum resolution: 0.1 Hz Sa
13、me as internal reference oscillator Standard Aging rate: 1 x 106/day (compared to after 15 minutes warm-up) Temperature characteristics: 5 x 106(0 to 50C) Option 01 Aging rate: 2 x 108/day (compared to after 24 hours warm-up) Temperature characteristics: 5 x 108(0 to 50C) MS4662A Continued on next p
14、age SAW filter measurement with time gate function Time domain gate function is very useful for eliminating test fixture leakage signals. RadioFans.CN 收音机爱 好者资料库 For product ordering information, see pages 4-215 NETWORK ANALYZERS 3 Test port output characteristics Aperture frequency fixed mode (GPDL
15、Y): delay range (DRG); 40 ns to 400 ms (1-2-4 sequence, aperture frequency = 0.4/DRG) Aperture frequency free mode (GPDLY): 1 Hz (correspond to 400 ms) to 400 MHz (correspond to 1 ns) High-speed mode (HSDLY): = /(360 x aperture frequency) : phase measurement range, aperture frequency = SPAN x smooth
16、ing aperture (%). Smoothing aperture can be set between 20 to 2/MEP x 100 (%). 2.78 x 105/aperture frequency, DRG/14400 when set by DRG Phase measurement dynamic accuracy/(360 x aperture frequency) Test port level (input) 10 to 0 dB 0 to 40 dB 40 to 50 dB 50 to 60 dB 60 to 70 dB 70 to 80 dB 80 to 90
17、 dB 6.0 1.0 GHz Measurement accuracy 0.3 0.3 0.8 2.0 6.0 20 6.0 1.0 GHz 0.3 0.8 2.0 6.0 20 Test port level (input) +10 to 0 dB 0 to 40 dB 40 to 50 dB 50 to 60 dB 60 to 70 dB 70 to 80 dB 80 to 90 dB 0.30 dB 1.0 GHz Measurement accuracy 0.05 dB 0.05 dB 0.10 dB 0.30 dB 1.20 dB 4.00 dB 0.30 dB 1.0 GHz 0
18、.05 dB 0.10 dB 0.30 dB 1.20 dB 4.00 dB Measurement accuracy Compared to 10 dBm at test port level, RBW: 10 Hz) Dynamic accuracy Measurement range Display resolution Dynamic accuracy 180(resolution: 0.001) 0.01/div to 50/div (1-2-5 sequence) Measurement accuracy Compared to 10 dBm at test port level,
19、 RBW: 10 Hz) Frequency 100 to 500 kHz 500 kHz to 2 GHz 2 to 3 GHz Deviation 0.5 to +2.5 dB 1.5 to +1.5 dB 2.0 to +2.0 dB Frequency 100 to 500 kHz 500 kHz to 2 GHz 2 to 3 GHz Deviation 0.5 to +2.5 dB 1.5 to +1.5 dB 2.0 to +2.0 dB GPC-7 +20 dBm, DC 40 V (AC couple) 90 dBm (100 kHz to 80 MHz, RBW: 1 kH
20、z) 80 dBm (80 MHz to 3 GHz, RBW: 1 kHz) 0 dB, 20 dB (switching error: 1 dB) Range: 70 to +10 dBm Accuracy: 1.0 dB (100 MHz, 0 dBm) Linearity: 0.5 dB (10 to +8 dBm, compared to 100 MHz/0 dBm) Resolution: 0.01 dB Output level deviation: Compared to 100 MHz/0 dBm Signal purity Test port connector Frequ
21、ency RBW Maximum input level Average noise level Crosstalk Measurement range Display resolution SSB phase noise (offset frequency: 10 kHz): 90 dBc/Hz (100 kHz to 80 MHz), 85 dBc/Hz (80 MHz to 1 GHz), 80 dBc/Hz (1 to 3 GHz) Non-harmonic spurious: 30 dBc (output level: 0 dBm) Harmonic distortion: 25 d
22、Bc (output level: 0 dBm) N-J 100 kHz to 3 GHz 0 dBm (DC couple) Measurement of transmission characteristics (S21, TB): 90 dBm (100 kHz to 80 MHz, RBW: 1 kHz), 80 dBm (80 MHz to 3 GHz, RBW: 1 kHz) Measurement of reflection characteristics (S11, TA): 70 dBm (100 kHz to 80 MHz, RBW: 1 kHz), 90 dB (100