FT-7900R_SM.pdf
《FT-7900R_SM.pdf》由会员分享,可在线阅读,更多相关《FT-7900R_SM.pdf(50页珍藏版)》请在收音机爱好者资料库上搜索。
1、FT-7900R/E Technical Supplement Dual Band FM Transceiver FT-7900R/E Technical Supplement Introduction This manual provides technical information necessary for servicing the FT-7900R/E Transceiver. Servicing this equipment requires expertise in handling surface-mount chip components. Attempts by non-
2、qualified persons to service this equipment may result in permanent damage not covered by the warranty, and may be illegal in some countries. Two PCB layout diagrams are provided for each double-sided circuit board in the transceiver. Each side of thr board is referred to by the type of the majority
3、 of components installed on that side (“leaded” or “chip-only”). In most cases one side has only chip components, and the other has either a mixture of both chip and leaded components (trimmers, coils, electrolytic capacitors, ICs, etc.), or leaded components only. While we believe the technical inf
4、ormation in this manual to be correct, Vertex Standard assumes no liability for dam- age that may occur as a result of typographical or other errors that may be present. Your cooperation in pointing out any inconsistencies in the technical information would be appreciated. Specifications . A-1 Explo
5、ded View check with your dealer. B-1FT-7900R/E Technical Supplement Exploded View realignment should not be done until after the faulty component has been replaced. We recommend that servicing be performed only by au- thorized Vertex Standard service technicians who are ex- perienced with the circui
6、try and fully equipped for re- pair and alignment. Therefore, if a fault is suspected, con- tact the dealer from whom the transceiver was purchased for instructions regarding repair. Authorized Vertex Stan- dard service technicians realign all circuits and make com- plete performance checks to ensur
7、e compliance with fac- tory specifications after replacing any faulty components. Those who do undertake any of the following alignments are cautioned to proceed at their own risk. Problems caused by unauthorized attempts at realignment are not covered by the warranty policy. Also, Vertex Standard m
8、ust reserve the right to change circuits and alignment procedures in the interest of improved performance, with- out notifying owners. Under no circumstances should any alignment be attempt- ed unless the normal function and operation of the trans- ceiver are clearly understood, the cause of the mal
9、func- tion has been clearly pinpointed and any faulty compo- nents replaced, and the need for realignment determined to be absolutely necessary. Required Test Equipment The following test equipment (and thorough familiarity with its correct use) is necessary for complete realignment. Correction of p
10、roblems caused by misalignment result- ing from use of improper test equipment is not covered under the warranty policy. While most steps do not re- quire all of the equipment listed, the interactions of some adjustments may require that more complex adjustments be performed afterwards. Do not attem
11、pt to perform only a single step unless it is clearly isolated electrically from all other steps. Have all test equipment ready before be- ginning, and follow all of the steps in a section in the or- der presented. ?Regulated DC Power Supply: adjustable from 11.5 to 16 VDC, 10 A ?RF Signal Generator
12、 with calibrated output level at 500 MHz ?Frequency Counter: 0.1 ppm accuracy at 500 MHz ?AF Signal Generator ?SINAD Meter ?Oscilloscope ?Spectrum Analyzer ?Deviation Meter (linear detector) ?AF Millivoltmeter ?AF Dummy Load: 8-Ohm, 5 W ?DC Voltmeter: high impedance ?Inline Wattmeter with 5% accurac
13、y at 500 MHz ?50-Ohm non-reactive Dummy Load: 50 watts at 500 MHz ?VHF/UHF Sampling Coupler Set up the test equipment as shown below, and apply 13.8 VDC power to the transceiver. E-1 Power Supply 13.8 VDC Pin 5 EXT SP Frequency Counter Deviation Meter Inline Wattmeter 50-ohm Dummy Load RF Sampling C
14、oupler RF Signal Generator 8-ohm Dummy Load SINAD Meter AF Signal Generator FT-7900R/E Technical Supplement Alignment Alignment Preparation & Precautions A dummy load and inline wattmeter must be connected to the main antenna jack in all procedures that call for transmission, except where specified
15、otherwise. Correct alignment is not possible with an antenna. After complet- ing one step, read the following step to determine wheth- er the same test equipment will be required. If not, re- move the test equipment (except dummy load and watt- meter, if connected) before proceeding. Correct alignme
16、nt requires that the ambient temperature in the repair shop be the same as that of the transceiver and test equipment, and that this temperature be held constant between 20 C and 30 C. When the transceiver is brought into the shop from hot or cold air it should be allowed some time for thermal equal
17、ization with the en- vironment before alignment. If possible, alignments should be made with oscillator shields and circuit boards firmly affixed in place. Also, the test equipment must be thoroughly warmed up before beginning. Notes: Signal levels in dB referred to in alignment are based on 0 dB =
18、0.5 V (closed circuit). Entering the Alignment mode Alignment of the FT-7900R/E is performed using a front- panel software-based procedure. To perform alignment of the transceiver, it must first be placed in the “Align- ment Mode,” in which the adjustments will be made and then stored into memory. T
19、o enter the Alignment mode: 1.Press and hold in the MHz(PRI) key while turning the radio on. 2.Rotate the DIAL konb so select menu “F-8 NOR/CH.” 3.Press and hold in the BAND(SET) key for 1/2 sec- ond. The radio is turned off automatically, and then switched on again afterwards. 4.Press and hold in t
20、he PWR( ) switch for 1/2 sec- ond to turn the radio off. 5.Press and hold in the V/M(MW) key while turning the radio on. The display will be show in the illus- tration at the right. 6.Press and hold in the PWR( ) switch for 1/2 sec- ond to turn the radio off. 7.Press and hold in the MHz(PRI) key and
21、 the Hyper Memory 5 key while turning the radio on. 8.Press the front panel keys in the following sequence. MHz(PRI) ? TONE(HM/RV) ?LOW(ACC) ? BAND(SET) ? V/M(MW) ? SCAN(SEL) ? S.SCH(ARTS) 9.Press and hold in the (L) key to cause “A-0 REF.xxH” to appear on the display, this signifies that the trans-
22、 ceiver is now in the “Alignment mode.” PLL Reference Frequency 1.Rotate the DIAL knob to set the display to “B4006”, then set the Transmit Power Level to “LOW” by press- ing the LOW(ACC) key repeatedly. 2.Press the BAND(SET) key while pressing and hold- ing in the (L) key, if needed, to set the Ali
23、gnment parameter to “A-0 REF.xxH”. 3.Press the PTT switch to activate the transmitter, and adjust the DIAL knob while pressing and holding the (L) key, if needed, so that the counter frequency reading is 435.050 MHz (100 Hz). RF Front-end Tuning 1.Connect the DC voltmeter to TP1010 on the MAIN Unit,
24、 then inject a 439.050 MHz signal at a level of +10 dB (with 1 kHz modulation 3.5 kHz deviation) from the RF Signal Generator. 2.Rotate the DIAL knob to set the display to “B4906”. 3.Press the BAND(SET) key while pressing and hold- ing the (L) key to set the Alignment parameter to “A-1 TUN.xxH”. 4.A