Anritsu anritsu-emi test 电路图.pdf
《Anritsu anritsu-emi test 电路图.pdf》由会员分享,可在线阅读,更多相关《Anritsu anritsu-emi test 电路图.pdf(10页珍藏版)》请在收音机爱好者资料库上搜索。
1、RADIO COMMUNICATIONS, EMI MEASURING TEST INSTRUMENTS Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . 432 Measuring Receiver . . . . . . . . . . . . . . . . . . . . . . . . 433 Radio Communication Analyzer . . . . . . . . . . . . . . 435 Frequency Converter . . . . . . . . . . .
2、 . . . . . . . . . . . . 435 Interference/Field Strength Meters . . . . . . . . . 435, 436 Antennas . . . . . . . . . . . . . . . . . . . . . . . . . . . . 436, 437 EMI Measuring Systems . . . . . . . . . . . . . . . . . . . . 438 EMI Probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、 . 440 EMI Probe Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 440 Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . 440 431 RadioFans.CN 收音机爱 好者资料库 RADIO COMMUNICATIONS, EMI MEASURING TEST INSTRUMENTS 432For product ordering information, see pages 4 10 Spectrum analyz
4、ers MS2651B, MS2661B/C9 kHz to 3 GHz MS2663C9 kHz to 8.1 GHz Pre-amplifierMH648A100 kHz to 1200 MHz Pulse limiterESH3-Z29 kHz to 30 MHz Absorption clamp KT-1030 to 1000 MHz KT-2030 to 1000 MHz Dipole antennaMP534A25 to 520 MHz TripodMB9A Dipole antennaMP651A470 to 1700 MHz TripodMB9A Log-periodic an
5、tennaMP666A200 to 2000 MHz TripodMB9A PoleMB18B Biconical antennaBBA910630 to 300 MHz Line probe3701450 kHz to 30 MHz EMI probeMA2601B/C5 MHz to 1 GHz/1 to 50 MHz Fixed attenuatorMP721B6 dB Programmable attenuatorMN63A0 to 100 dB PrinterVP-870 PlotterMP5300-11 System software MX264001A (for MS2651B,
6、 MS2661B/C, MS2663C) Models and names Frequency range or attenuation Simplified EMI measurement system Noise measures Conducted interface Interference power Radiation noise All items EMI measuring instruments selection guide MS555B MG3641A MG3642A MG3633A 68000C, 69000B ML2437A/2438A ML2407A/2408A M
7、F2400B series ML524B S331B 54100A series MS4630B 37200C series MS2651B, MS2661B/C, MS2663C, MS2665C, MS2667C, MS2668C MS2683A Radio communica- tion analyzer Time-domain- capable spectrum analyzer Power meter Frequency counter Measuring receiver Site master Network analyzer Signal generator Anritsu m
8、odel Construction, maintenance Service areas TransmitterTransmitterReceiver Maintenance, troubleshoot- ing Receiver Parts Entrance circuitry Mobile equipmentBase station Equipment to be measured Selection guide (example of an application; various other types of measurement equipment are also availab
9、le) Type of measurement equipment RadioFans.CN 收音机爱 好者资料库 433 RADIO COMMUNICATIONS, EMI MEASURING TEST INSTRUMENTS 10 GPIB OPTION For Measuring Service Area Direct readout of field strength High precision level display (indication in 0.1 dB steps) Applications For field strength measurement Investig
10、ation to determine service areas Radio wave propagation test Measurement of spurious radiation from transmitter For other than field strength measurement Radio monitoring Measuring receiver High-sensitivity signal demodulation MEASURING RECEIVER ML524B 25 to 1000 MHz The ML524B have a full range of
11、features and functions plus de- modulation functions for various signals. Their compact, lightweight construction makes them suitable for a variety of measurement appli- cations. Use of the GPIB interface option allows easy configuration of an automatic test system controlled by a personal computer.
12、 Features Very compact and lightweight High frequency stability (A synthesizer local is used. Its reference oscillator has a high frequency stability of 1 x 106.) Wide dynamic range (80 dB without switching) Automatic gain calibration RF inputNominal impedance 50 , N-type connector Range25.0000 to 9
13、99.9999 MHz Display Liquid crystal display, 6 digits Minimum digit: 1 kHz (0.5 kHz is displayed using a symbol of .) FrequencyResolution12.5 kHz (120 kHz bandwidth), 1 kHz (15 kHz bandwidth) SettingKeyboard and FINE dial MemoryUp to 100 frequencies can be stored and recalled. Reference frequency sta
14、bility1 x 106 Minimum value5 dBV (25 to 300 MHz), 5 dBV (300 to 999.999 MHz) Voltage Maximum value100 dBV (25 to 999.999 MHz) measurementSettingC/N: 6 dB (at minimum value), Bandwidth: 15 kHz (E.M.F.) Accuracy (digital display)2 dB (minimum value +6 dB) Comparison oscillatorPulse generator Minimum v
15、alue5 to 19 dBV/m (25 to 300 MHz), 19 to 32 dBV/m (300 to 999.999 MHz) Field strength Maximum value0 to 114 dBV/m (25 to 300 MHz), 114 to 120 dBV/m (300 to 999.999 MHz) measurement SettingC/N: 6 dB (at minimum value), Bandwidth: 15 kHz Type of antennaHalf-wave dipole 6 dB bandwidth15 2 kHz (15 kHz b
16、andwidth), 120 20 kHz (120 kHz bandwidth) Selectivity Detuning characteristics15 kHz bandwidth50 dB (20 kHz off center) Image ratio60 dB (at 25.000 to 299.999 MHz), 45 dB (at 300 to 999.999 MHz) Residual spurious10 dBV (typical near 50, 130, 600, 1000 MHz) Detection systemAverage value Specification
17、s Continued on next page Custom-made product RadioFans.CN 收音机爱 好者资料库 RADIO COMMUNICATIONS, EMI MEASURING TEST INSTRUMENTS 434For product ordering information, see pages 4 10 Ordering information Please specify model/order number, name, and quantity when ordering. Model/Order No.Name Main frame ML524
18、BMeasuring Receiver Standard accessories J0231Connecting cord for recorder (3.5 plug alligator clips), 1.5 m:1 pc J0144DC power cord (RM12BPG-5S 2CC7 arrow tips), 1.5 m:1 pc A0002Earphone:1 pc MZ114AAC Power Pack:1 pc B0259Carrying case:1 pc W0285AEML524A/B/C operation manual:1 copy Options ML524B-0
19、1GPIB ML524B-05Terminated voltage indication Model/Order No.Name Optional accessories MP612ARF Fuse Holder MP613ARF Fuse Element (5 pcs/set) A0004Headphone MZ110BBattery Pack (with six Ni-Cd batteries) MZ115BBattery Charger MZ114AAC Power Pack MP635ALog-periodic Antenna MZ137ABattery Pack MB19A Trip
20、od (for MP635A) J0006 GPIB cable, 0.5 m J0007 GPIB cable, 1 m J0008 GPIB cable, 2 m J0009 GPIB cable, 4 m MP663ADipole Antenna (with pole and tripod) MP651BDipole Antenna MP18APole (for MP651B) MB9A Tripod (for MP651B) MP520BCM Directional Coupler (25 to 1000 MHz, 75 , NC-type connector) MP520DCM Di
21、rectional Coupler (100 to 1700 MHz, 50 , N-type connector) Power supply selection guide Type of power supplyModelWhen used with ML524BRemarks MZ137A Battery Pack Operates continuously for about 2.5 toTwelve alkaline dry cells (LR20) Dry cell 5 hours1 Does not permit GPIB operation Sold separately MZ
22、110B Battery Pack Six Ni-Cd batteries with the same dimensions Operates continuously for about 30 to as R14 battery, chargeable 200 to 300 times Ni-Cd battery60 minutes1 Fits inside the receiver Sold separately Does not permit GPIB operation MZ114A AC Power Pack DC power is fed to the EXT +12 V term
23、inal AC supplyPermits operation at 100/220 Vac of the receiver. One of accessories suppliedPermits GPIB operation EMC, safety External DC supply The receiver can be operated directly One DC power cord is supplied. from an external 12 Vdc supply. Permits GPIB operation Two MZ110B can be charged simul
24、taneously. Battery chargerMZ115B Battery Charger Sold separately EMC, safety 1: For continuous reception after power on, with calibration performed once only (more calibrations reduce the operating time). Operating is also affected by how the battery has been stored, and operating temperature. Displ
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Anritsu anritsu-emi test 电路图 emi
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


