BK 1856D_manual 电路图.pdf
《BK 1856D_manual 电路图.pdf》由会员分享,可在线阅读,更多相关《BK 1856D_manual 电路图.pdf(23页珍藏版)》请在收音机爱好者资料库上搜索。
1、1 Instruction Manual Model 1856D 3.7GHz Frequency Counter RadioFans.CN 收音机爱 好者资料库 2 WARRANTY Warranty service covers a period of one year from the date of original purchase. In case of technical failure within one year, repair service will be provided by our service center or sales outlet free of ch
2、arge. We charge customers for repairs after the one-year warranty period has expired. We charge for repairs regardless of the warranty period if failure resulted from the users negligence, natural disaster or accident. For more professional repair service, be sure to contact our service center or sa
3、les outlet. RadioFans.CN 收音机爱 好者资料库 3 Introduction Thank you for purchasing our product. Electronic measuring instruments produced by us are high technology products made under strict quality control. We guarantee their exceptional precision and utmost reliability. For proper use of the product, ple
4、ase read this operation manual carefully. Note ? To maintain the full precision and reliability of this product, use it within the temperature range of 10 C to 35 C (50 oF to 95 oF), and within a humidity of 45% to 85%. ? After turning on the power, allow a warm up period of about 30 minutes before
5、use. ? This equipment should be used with a triple line power cord for safety. ? Due to ongoing product development and improvement, things such as exterior design and technical specifications can change without prior notice. ? If you have further questions concerning use of this product, visit . Sa
6、fety Summary Please take a moment to read these operating instructions thoroughly and completely before operating this instrument. Pay particular attention to WARNINGS concerning conditions and actions that pose a hazard to the user and CAUTIONS describing conditions and actions that may damage the
7、instrument. ? Before every use, inspect the instrument and other accessories for signs of damage or abnormality. ? Keep your body isolated from ground. ? Never touch exposed wiring, connections or any live circuit conductors. ? Do not install substitute parts or perform any unauthorized modification
8、s on the instrument. ? Use caution when working above 60V DC or 30V AC rms. Such voltages pose a shock hazard. ? Remember that line voltage is present on circuit points such as on-off switches, fuse, power transformers, etc., even when the equipment is turned off. ? Remember that high voltage may ap
9、pear at unexpected points in defective equipment. Safety Symbols DANGEROUS VOLTAGE AC-ALTERNATING CURRENT DC-DIRECT CURRENT SEE EXPLANATION IN MANUAL GROUND FUSE RadioFans.CN 收音机爱 好者资料库 4 CONTENTS 1. PRODUCT DESCRIPTION 1-1. Introduction - (5) 1-2. Technical Specifications - (6) 1-3. Equipment Ratin
10、gs - (9) 1-4. Supplied Accessories - (10) 2. INSTALLATION 2-1. Initial Inspection - (10) 2-2. Connecting AC Power - (10) 2-3. Cooling and Ventilation - (10) 2-4. Position - (10) 2-5. Warming-Up - (11) 3. OPERATION 3-1. Controls, Indicators and Connectors - (11) 3-2. Operating Instructions- (14) 3-3.
11、 Frequency Measurements - (14) 3-4. Period Measurements - (16) 3-5. Total Measurements - (16) 3-6. RPM Measurements - (16) 3-7. Use of RS-232C Serial Interfacing - (17) 4. MAINTENANCE 4-1. Fuse Replacement - (18) 4-2. Adjustment and Calibration - (18) 4-3. Cleaning and Decontamination - (18) 5. OTHE
12、R 5-1. BNC Cable Considerations - (19) 5-2. Attenuator Probes - (20) 5-3. Line Frequency Measurements- (20) 1. PRODUCT DESCRIPTION 5 1-1. Introduction This reciprocal FREQUENCY COUNTER is a microprocessor-controlled instrument for frequency measurement. Due to uniquely developed LSI circuitry in an
13、expanding/reciprocal system, high accuracy with 9-digit resolution is achieved with a one second gate time. It covers a frequency range of from 0.1 Hz to 3.5 GHz based on a 10 MHz TCO (Temperature Controlled Oscillator). Other features include: ? RPM (Revolutions Per Minute) Measuring Function ? Ext
14、ernal Frequency Standard Input with 9 Digit LED Display ? Attenuator ? Period ? Total ? Low Pass Filter ? Line Filter Also provided is a self-test function for a quick check of several operating modes. Each mode can be selected by a front panel push button switch with automatic decimal points and in
15、dicators. The high accuracy, sensitivity and versatility of this counter make it an extremely valuable instrument to the scientist, engineer, experimenter and communications technician. Lightweight and compact size make it practical for use by the hobbyist or field technician. 6 1-2. Technical Speci
16、fications g INPUT A CHARACTERISTICS h FREQUENCY RANGE: 0.1 Hz to 100 MHz (DC coupled) 30 Hz to 100 MHz (AC coupled) h SENSITIVITY: 30 mV rms h COUPLING: AC or DC selectable. h IMPEDANCE: 1 M resistance shunted by 40 pF h ATTENUATOR: x1 or x10 switch selectable h LOW PASS FILTER: -3 dB point at appro
17、x. 100 KHz, switch selectable h ACCURACY: Time base error resolution (Table 1) h Resolution and Number of Displayed Digits Time Base Selector INT EXT INT EXT INT EXT INT EXT Gate Time 0.01S 0.1S 1S 10S Number of Display Digits 5 6 6 7 7 8 8 9 Frequency (Input A) RESOLUTION 0.1 Hz-0.99 Hz 10 uHz 1 uH
18、z 1 uHz 0.1 uHz 0.1 uHz 10nHz 10nHz 1nHz 1 Hz-9.9 Hz 0.1mHz 10 uHz 10 uHz 1 uHz 1 uHz 0.1 uHz 0.1 uHz 10nHz 10 Hz-99 Hz 1 mHZ 0.1mHz 0.1mHz 10 uHz 10 uHz 1 uHz 1 uHz 0.1 uHz 100 Hz-999 Hz 10mHz 1 mHz 1 mHz 0.1mHz 0.1mHz 10 uHz 10 uHz 1 uHz 1 KHz-9.9 KHz 0.1 Hz 10 mHz 10 mHz 1 mHz 1 mHz 0.1 Hz 0.1 mH
19、z 10 uHz 10 KHz-99 KHz 1 Hz 0.1 Hz 0.1 Hz 10 mHz 10 mHz 1 mHz 1 mHZ 0.1mHz 100 KHz-999 KHz 10 Hz 1 Hz 1 Hz 0.1 Hz 0.1 Hz 10 mHz 10 mHz 1 mHZ 1 MHz-9.9 MHz 100 Hz 10 Hz 10 Hz 1 Hz Hz 0.1 Hz 0.1 Hz 10 mHz 10 MHz-99 MHz 1 KHz 100 Hz 100 Hz 10 Hz 10 Hz 1 Hz 1 Hz 0.1 Hz 100MHz 10 KHz 1 KHz 1 KHz 100 Hz 1
20、00 Hz 10 Hz 10 Hz 1 Hz (Table 1) 7 h Max. Input Voltage Level FIG. 1 MAX. Input Level. (Input A) h PERIOD RANGE: 10 nS to 10 S DISPLAY: n/u/m (nano/micro/milli) Sec. with decimal point h TOTAL RANGE: 10 Hz to 30 MHz CAPACITY: 0 to 999 999 999, OVER FLOW : “OF” h RPM RANGE: 600 to 600 x 106 RPM, OVER
21、 FLOW : “OF” g INPUT C. CHARACTERISTICS h FREQUENCY RANGE: 80 MHz to 3.5 GHz h SENSITIVITY: 15mV from 80 MHz to 2000 MHz 20mV from 2000 MHz to 3.0 GHz 30mV from 3.0GHz to 3.2GHz 50mV from 3.2GHz to 3.5GHz h COUPLING: AC only h IMPEDANCE: 50 5% h MAX. INPUT LEVEL: 3 V rms sine wave 3 0 0 2 5 0 1 5 0
- 配套讲稿: