1、 1 Instruction Manual Model 1785B, 1786B, 1787B the third conductor being the ground. The power supply is grounded only when the power-line cord is plugged into an appropriate receptacle. Do not operate your power supply without adequate cabinet ground connection. 9 1.2 Output Checkout The following
2、 procedures check to ensure that the power supply develops its rated outputs and properly responds to operation from the front panel. 1.2.1 Voltage Output Checkout The following steps verify basic voltage functions without load. 1. Turn on the power supply. 2. Enable the outputs. Press key to let th
3、e ON annunciator and the CV annunciator turn on to light. Notice: if the voltage value flash, then the power supply is in Set mode, Set mode means that the VFD display shows the setting output voltage and current. Or the power supply is in Meter mode, Meter mode” means that the VFD display shows the
4、 actual output voltage and current. 3. Check that the front-panel voltmeter properly responds to number keys Set some different voltage values, then wait till the Meter mode to check if the VFD displayed voltage value is the same as the set voltage value, and to check if the VFD displayed current va
5、lue is nearly zero. 4. Ensure that the voltage can be adjusted from zero to the full rated value. 1.2.2 Current Output Checkout The following steps check basic current functions with a short across the power supplys output. 1. Turn on the power supply. 2. Disable the output Press key to ensure that
6、the output is disabled. The ON annunciator is turned off. 3. Connect a short across (+) and (-) output terminals with an insulated test lead. Use a wire size sufficient to handle the maximum current. 4. Enable the output. Press key to ensure that the output is enabled. The ON annunciator is turned o
7、n. 5. Adjust the voltage value to 1.0 volt. Adjust the voltage to 1.0 volt to ensure the power supply is in CC operation mode. The CC annunciator will turn on. 6. Adjust the current value. Set some different voltage values, then wait till the Meter mode to check if the VFD displayed current value is
8、 the same as the set voltage value, and to check if the VFD displayed voltage value is nearly Warning: To satisfy safety requirements, load wires must be heavy enough not to overheat when carrying the maximum short-circuit output current of the power supply. If there is more than one load, then any
9、pair of load wires must be capable of safety carrying the full-rated current of the power supply. Out on/off Out on/off Out on/off 10 zero. 7. Ensure that the current can be adjusted from zero to the full rated value. 8. Turn off the power supply and remove the short wire from the output terminals.
10、1.3 If the Power Supply Does Not Turn On Use the following steps to help solve problems you might encounter when turning on the instrument. If you need more help, refer to chapter 6 for instructions on returning the instrument to the supplier for service. 1. Verify that there is AC power to the powe
11、r supply. First, verify that the power cord is firmly plugged into the power receptacle on the rear panel of the power supply. You should also make sure that the power source you plugged the power supply into is energized. Then, verify that the power supply is turned on. 2. Verify the power-line vol
12、tage setting. The line voltage is set to the proper value for your country (110VAC or 220VAC. Change the voltage setting if its not correct. 3. Verify that the correct power-line fuse is installed. If the fuse was damaged, please see the table below to replace the fuse for your power supply. Fuse De
13、scription Fuse 2.5A T 250V for 220VAC Fuse 5A T 250V for 110VAC 1.4 To Adjust the Carrying Handle To adjust the position, grasp the handle by the sides and pull outward. Then, rotate the handle to the desired position. 11 Bench-top viewing positions Carrying position 1.5 To Rack Mount the Instrument
14、 You can mount the power supply in a standard 19-inch rack cabinet using the IT-E151 rack mount kit. Note: Remove the carrying handle and the two plastic ears before rack-mounting the instrument. To remove the handle, grasp the handle by sides and pull outwards and rotate it to a special position to
15、 let the arrow on the handle and the arrow on the plastic ears be in opposite directions, then pull the handle outward. After removing the handle, you can use a screwdriver to remove the two plastic ears. To rack mount a single instrument, order rack mount kit IT-E151 Side view of rack mounting a si
16、ngle instrument 12 To rack mount two instruments side-by-side, order rack mount kit IT-E151, you neednt to use the front cover panel. Dimension unit (mm) Chapter 2 Specifications 2.1 Specifications Parameter 1785B 1786B 1787B 1788 Voltage 0 18V 0 32V 0 72V 0 32V Current 0 5A 0 3A 01.5A 06A Output Ra
17、tings, ( 0 C - 40 C) LVP 0 19V 0 33V 0 73V 0 33V Voltage 0.01% + 3mV Model 1788 = 0.02% + 5mV Load Regulation, (% of output+offset) Current 0.1% + 2mA Voltage 0.1% + 3mV Line Regulation, (% of output+offset) Current 0.1% + 2mA Voltage 10mV Programming Resolution Current 10mA Voltage 0.05% + 15mV(20V
18、) Model 1788 = 0.05% + 120mV(= 20V) Readback Resolution Current 0.1% + 15mA 13 Voltage 0.05% + 10mV Programming Accuracy, 12months, ( 25 C 5 C) (% of output+offset) Current 0.2% +10mA Voltage 0.05%+15mV(20V), 0.05%+120mV(= 20V) Readback Accuracy 12months, (25 C 5 C) (% of output+offset) Current 0.1%
19、 +15mA Voltage = 1mVrms/3mVp-p Ripple (20Hz 20MHz) Current 5mArms Voltage 0.02%+5mV Temperature Coefficient, (0 C 40 C) (% of output+offset) Current 0.1% +5mA Voltage 0.02%+15mV(20V), 0.02%+120mV(= 20V) Readback Yemperature, Coefficient, (% of output+offset) Current MAX VOLT) Please be well known th
20、at the Max voltage value should be in the range of each type of IT68xx Power supply. Step1. Press key. V-Set Enter Enter Save Recall Enter Menu Enter I-Set 9 9 9 9 0 0 0 0 Note: 1. If the function keys were locked by password, you need to enter the correct password after you press function keys (V-s
21、et, I-set, Save, Recall and Menu), then you can do the settings. 2. If you want to cancel a function operation (V-set, I-set, Save, Recall or Menu), just press key to exit. Esc 17 Step2. Select MAX VOLT by using? and ? key. Step3. Press key. Step4. Change the voltage value by using numeric keys to o
22、r ?and ?key. Step5. Press key. ? Initiating the Output state(INIT OUT) This instruction can initiate the output state when the power supply is powered on. If you select ON, the power supply will initiate the output to OFF state when the power supply is powered on. If you select OFF, the output will
23、remain the same state as last time you turned off the power supply ? Initiating the Output Voltage (INIT VOLT) This instruction can set the initial output voltage. If you select ON, the power supply will initiate the output voltage to 0Volt when the power supply is powered on. If you select OFF, the
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BK PRECISION 1785B 86B 87B 1788 Instruction 电路图 1785 86 87
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-199465.html



Marshall-9100-62-02-Schematic电路原理图.pdf