BK PRECISION 2650A Manual 电路图.pdf
《BK PRECISION 2650A Manual 电路图.pdf》由会员分享,可在线阅读,更多相关《BK PRECISION 2650A Manual 电路图.pdf(88页珍藏版)》请在收音机爱好者资料库上搜索。
1、v 03042009 Model 2650A/2651 Series 3.3 GHz/8.5 GHz Spectrum Analyzer USER MANUAL RadioFans.CN 收音机爱 好者资料库 i Before Using the Product Please note the following described on the back panel. For safe use: 1) When a bnormal s ound, abnormal s mell or smoke is found, stop us ing the product and remove the
2、 battery and AC adapter. 2) Never handle this product with wet hands to prevent risks of electric shock, fire, or damage. 3) Never use this product under lightning conditions to prevent risks of damage. 4) Never us e any AC a dapter ot her t han s pecified, or it w ill caus e da mage. Connect the po
3、wer cable only to three-terminal outlet for protection from static electricity, otherwise this product or a device under test may be damaged. 5) Never use any battery other than specified, or it may damage this product. Turn off the power and disconnect the AC adapter before removing the battery out
4、 of the battery compartment. 6) Be sure to charge the battery as specified in the instructions in this manual. Moreover, an explosion, fire or smoke may occur if battery is handled improperly. Please read the notes for handling the battery. RadioFans.CN 收音机爱 好者资料库 ii Set clock function The time info
5、rmation is set at Japan standard time. Set the year, month, day and time when the 2650A series is used for the first time. (Refer to “24.4 Setting the clock” for the details.) Quality assurance Warranty If the defect by our responsibility occurs within one year after delivered, it shall be repaired
6、free of charge. However, this warranty does not cover such defect that : 1) is caused by a fire or natural disasters. 2) is caused by inappropriate handling such as dropping while moving the unit delivered. 3) is caused by handling in contradiction to usage or precautions described in the operating
7、manual. 4) is caused by modification or misuse. We will not be responsible for direct or indirect damage caused by use or defect of this product. Refer to the end of this manual for details. Warm-up time Warm up the product for at least ten minutes after turning on the power in order to stabilize th
8、e internal circuit. Precautions for storage 1) Avoid direct sunlight or dust. 2) Store this unit in a place where temperature is between -20 C to 60 C, humidity less than 60 C/70 %RH and variations in temperature and humidity are small. After service Please c ontact us w ithout he sitation i f you h
9、a ve a ny que stions a bout t his product: B f = SPAN / (10 to 50) (corresponding to 0.2 to 1 div) Example: judging a spectrum displayed at 6.92 GHz (setting : center frequency 6.92 GHz and SPAN 500 MHz) 1. Set the center frequency to = 6.94GHz. 2. A spectrum at 6.92 GHz (shifting left by f from 6.9
10、4 GHz) is correct. A spectrum at 6.98 GHz (shifting right by 2f from 6.94 GHz) is spurious. * Additionally, a spurious response mentioned above shifting right by 2f at band 1+ is largest, and other spurious response are about 25 to 50 dB smaller than that. 17. Marker Frequency = (freq. at active mar
11、ker) (freq. at reference marker) Level = (level at active marker) (level at reference marker) 4. By pushing , the marker is erased (marker off). 17.2 Normal Peak Search Menu of normal peak search When is pushed, the following function menu is displayed. 1. When is pushed, the marker moves to the max
12、imum peak position of spectrums. 2. When is pushed, the marker moves to the next highest peak. Fifty or less peaks are available. 3. When is pushed, the function menu is returned to the main menu of marker function. 17.3 Zone Peak Search Menu of normal peak search When is pushed, the following funct
13、ion menu is displayed. RETURN F1 F2 F3 F4 F5 F6 PEAK SEARCH NEXT PEAK F1 F2 F3 F4 F1 F2 F6 F5 36 At the Zone mode, the marker automatically moves to the maximum peak point within the range set beforehand. When entering this mode, the zone is displayed with thin blue shadow in the spectrum display ar
14、ea. The marker moves to maximum level within this zone at each sweep. The center of the zone can be adjusted by pressing The width of the zone can be adjusted by pressing Note: The marker does not move in HOLD. 17.4 Change Unit of Marker Level When is pushed, the unit of the marker level is changed.
15、 If the unit of the reference level is dBm, it can be changed to dBm W. If the unit of the reference level is dBV, dBmV or dBV, it can be changed to dBV, dBmV, dBV V. If the unit of the reference level is dBV/m, it can be changed to dBV/m V/m. If the unit of the reference level is dBA/m, it can be c
16、hanged to dBA/m A/m. Note: “V/M” is only displayed when the electric field strength measurement is selected “A/M” is only displayed when the magnetic field strength measurement is selected Each unit change as described above has their own sub-menu for more unit display options. They are shown below:
17、 W W, mW, W, nW, pW, fW V V, mV, V, nV V/m V/m, mV/m, V/m, nV/m A/m A/m, mA/m, A/m, nA/m 18. Save / Load When is pushed, SAVE/LOAD menu is displayed as follows. F1 F2 F3 F4 F5 F6 RETURN ZONE CENTER WIDTH F1 F2 F6 SAVE / LOAD 37 18.1 Selection of Storage Device 1. When is pushed, the built-in flash m
18、emory is selected as a storage device. When is pushed, the external USB memory is selected as a storage device. * Install the USB memory in USB A- plug on the right side firmly. Refer to the figure below. * Once you disconnect, then reconnect the same or a different USB flash memory drive, the 2650A
19、 series will not automatically recognize the new USB drive. After connecting the drive, you must first press the Save/Load key, followed by F5 key (USB) in order for the 2650A to see the new drive., then proceed as described below. . F1 F2 F3 F4 F5 F6 PRE SET SAVE MODE SELECT LOAD DELETE DEVICE MEM
20、USB PRE SET F4 F5 38 18.2 Save Function When is pushed, SAVE menu is displayed as follows. 1. In this function, the data is stored in the built-in memory or USB memory by CSV format. The data stored in USB memory can be used with a personal computer as a CSV file. “2650A_csvData” folder will automat
21、ically be created and the data will be stored in it as a file. 2. The object to be stored is selected with , or . SPECT: The current spectrum on the screen is stored. PARAM: The setting parameters are stored. BOTH: The spectrum and setting parameters are stored as one file. * The selected key will l
22、ook pushed-in on the display. 3. When is pushed, SAVE is executed. The data is stored based on the file name displayed in the active area (refer to “4. Explanation of screen”). As for the file name, refer to “18.3 About File Name”. Up to 200 files can be stored in the built-in memory. Up to 1000 fil
23、es can be stored in USB memory. 4. Pushing will return to the former menu. 18.3 About File Name 1. The file name is attached to the file stored using this function as follows. LABEL-SP001.csv (1) (2) (3) (4) (1) This is the label entered from the label function. Refer to “24.1 Label function.” Note:
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BK PRECISION 2650A Manual 电路图 2650
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf