Vertex_VX170_user.pdf
《Vertex_VX170_user.pdf》由会员分享,可在线阅读,更多相关《Vertex_VX170_user.pdf(88页珍藏版)》请在收音机爱好者资料库上搜索。
1、VHF FM TRANSCEIVER VX-170 OPERATING MANUAL VERTEX STANDARD CO., LTD. 4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan VERTEX STANDARD US Headquarters 10900 Walker Street, Cypress, CA 90630, U.S.A. YAESU EUROPE B.V. P.O. Box 75525, 1118 ZN Schiphol, The Netherlands YAESU UK LTD. Unit 12, Sun Valley
2、 Business Park, Winnall Close Winchester, Hampshire, SO23 0LB, U.K. VERTEX STANDARD HK LTD. Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road, Kwun Tong, Kowloon, Hong Kong Contents Scanning . 36 VFO Scanning. 37 Manual VFO Scan . 37 Programmed VFO Scan . 37 Memory Scanning . 38 How to Skip (Omit)
3、 a Channel during Memory Scan Operation . 38 Preferential Memory Scan . 39 Memory Bank Scan . 40 Programmable (Band Limit) Memory Scan (PMS) . 41 “Priority Channel” Scanning (Dual Watch). 42 Automatic Lamp Illumination on Scan Stop . 44 Band Edge Beeper. 44 Weather Alert Scan . 45 Emergency Channel
4、Operation . 46 Smart Search Operation. 47 Internet Connection Feature. 48 ARTS (Automatic Range Transponder System). 50 DTMF Operation . 53 DTMF Pager Operation . 55 Miscellaneous Settings . 58 Password . 58 Programming the Key Assignment . 59 Changing the Channel Steps. 59 Receive Battery Saver Set
5、up. 60 TX Battery Saver. 60 Disabling the TX/BUSY Indicator . 61 Automatic Power-Off (APO) Feature . 61 Transmitter Time-Out Timer (TOT) . 62 Busy Channel Lock-Out (BCLO) . 62 DCS Code Inversion . 63 Changing the TX Deviation Level . 64 Reset Procedures . 65 Cloning . 66 Set Mode. 68 Specifications
6、. 81 Installation of the FTD-7 DTMF Pager Unit. 80 General Description . 1 Accessories and a security Password feature, that will allow you to turn on and operate your transceiver only after you enter your Password. Additional features include a convenient access key for Vertex Standards WIRES (Wide
7、- coverage Internet Repeater Enhancement System), a transmit Time-Out Timer (TOT), Automatic Power-Off (APO), Automatic Repeater Shift (ARS), Vertex Standards exclu- sive ARTS (Auto-Range Transponder System) which “beeps” the user when you move out of communications range with another ARTS equipped
8、station, plus provision for reduction of the TX deviation in areas of high channel congestion. And an RF squelch circuit allows the owner to set the squelch to open at a programmable setting of the S- Meter, thus reducing guesswork in setting the squelch threshold. We appreciate your purchase of the
9、 VX-170, and encourage you to read this manual thor- oughly, so as to learn about the many exciting features of your exciting new Vertex Stan- dard hand-held transceiver! VX-170 OPERATING MANUAL2 SUPPLIED ACCESSORIES ?FNB-837.2 V, 1,400 mAh Rechargeable Nickel-Metal Hydride Battery Pack ?NC-88BOvern
10、ight Battery Charger (10-Hour) ?YHA-68Antenna ?Quick Draw Belt Clip ?Operating Manual ?Warranty Card AVAILABLE OPTIONS ?FNB-837.2 V, 1,400 mAh Rechargeable Nickel-Metal Hydride Battery Pack ?NC-88B/C/U?Overnight Battery Charger (10-Hour) ?VAC-370Desktop Rapid Charger ?CD-26Charger Cradle ?FBA-25ADry
11、 Cell Battery Case for 6 “AA” Alkaline Cells (not supplied) ?CN-3BNC-to-SMA Adapter ?CT-91Microphone Adapter ?E-DC-5BDC Cable with Cigarette-Lighter Adapter ?E-DC-6DC Cable; plug and wire only ?MH-57A4BSpeaker/Microphone ?CMP460AWaterproof Speaker/Microphone ?VC-27Earpiece/Microphone ?VC-24VOX Heads
12、et ?FTD-7DTMF Paging Unit ?:“B” suffix is for use with 100-120 VAC, “C” suffix is for use with 230-240 VAC, and “U” suffix is for use with 230 VAC. Availability of accessories may vary. Some accessories are supplied as standard per local requirements, while others may be unavailable in some regions.
13、 This product is designed to perform optimally when used with genuine Vertex Standard accessories. Vertex Stan- dard shall not be liable for any damage to this product and/or accidents such as fire, leakage or explosion of a battery pack, etc., caused by the malfunction of non- Vertex Standard acces
14、sories. Consult your Vertex Standard dealer for details regarding these and any newly-available options. Connection of any non-Vertex Standard-approved ac- cessory, should it cause damage, may void the Limited Warranty on this apparatus. ACCESSORIES the optimum input voltage is approximately 5 mV at
15、 2000 Ohms. Be sure to turn the transceiver and TNC off before connecting the cables, so as to prevent voltage spikes from possibly damaging your transceiver. When you are operating on Packet, switch the Receive Battery Saver OFF, as the “sleep” cycle may “collide” with the beginning of an incoming
16、Packet transmission, causing your TNC not to receive the full data burst. See page 60 for details regarding Battery Saver setup. INTERFACE OF PACKET TNCS VX-170 OPERATING MANUAL12 Hi! Im R. F. Radio, and Ill be helping you along as you learn the many features of the VX-170. I know youre anxious to g
17、et on the air, but I encour- age you to read the “Operation” section of this manual as thoroughly as possible, so youll get the most out of this fantastic new transceiver. Now. . .lets get operating! SWITCHING POWER ON AND OFF ?Be sure the Battery Pack is installed, and that the battery is fully cha
18、rged. Connect the antenna to the top panel ANTENNA jack. ?Rotate the top panels VOL/PWR knob (inner knob) out of the click-stop to turn on the radio. The current DC supply voltage will be indicated on the display for 2 seconds. After this 2 second interval, the display will resume its normal indicat
19、ion of the operating frequency. ?To turn the radio off, turn the VOL/PWR knob fully counter-clockwise into the click stop position. ADJUSTING THE AUDIO VOLUME LEVEL Rotate the VOL/PWR knob (inner knob) to adjust the re- ceiver level for a comfortable listing level, using the back- ground noise as a
20、reference. Clockwise rotation increases the volume level. OPERATION VX-170 OPERATING MANUAL13 OPERATION SQUELCH ADJUSTMENT ?To set the squelch, press the F key, followed by the MONI switch just below the PTT switch on the left side of the transceiver. ?Now rotate the DIAL (outer knob) to find the lo
21、west setting (“LVL 1” through “LVL 15”) that will just si- lence the background noise. Do not use a higher setting than necessary, or sensitivity to weak incoming signals will be degraded. ?Press the PTT switch momentarily when youve made the new setting; this will return you to normal operation (wi
22、thout having transmitted). 1) A special “RF Squelch” feature is provided on this radio. This feature allows you to set the squelch so that only signals exceeding a certain S-meter level will open the squelch. See page 18 for details. 2) If youre operating in an area of high RF pollution, you may nee
23、d to consider “Tone Squelch” operation using the built-in CTCSS Decoder. This feature will keep your ra- dio quiet until a call is received from a station sending a carrier which contains a matching (subaudible) CTCSS tone. Or, if your friends have radios equipped with DCS (Digital Coded Squelch) li
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Vertex_VX170_user
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


