Biddle BM100_BM101_UG 电路图.pdf
《Biddle BM100_BM101_UG 电路图.pdf》由会员分享,可在线阅读,更多相关《Biddle BM100_BM101_UG 电路图.pdf(12页珍藏版)》请在收音机爱好者资料库上搜索。
1、500 V. Analogue Insulation clean, and with no broken or cracked insulation. Replacement fuses must be of the correct type and rating. BM 100/4 Only U.K. Safety Authorities recommend the use of fused test leads when measuring voltage on high energy systems. When making a voltage measurement, the Test
2、 push must not be pressed. NOTE T H E I N S T R U M E N T S M U S T O N Y B E U S E D B Y S U I TA B LY T R A I N E D A N D C O M P E T E N T P E R S O N S. Symbols used on the instrument Caution: Refer to accompanying notes. Equipment protected throughout by Double Insulation (Class II). Equipment
3、complies with relevant EU Directives RadioFans.CN 收音机爱 好者资料库 OPERATION Preliminary Test lead check 1.Before each use of the instrument, inspect the test leads to confirm that their condition is good, with no damaged or broken insulation. 2. Insert the red and black test leads, terminated with the ap
4、propriate prods or clips, to their respective + and - terminal sockets. 3.Short the test lead prods or clips together. Set the selector switch to 2 . 4. Press the Test push. Check that the instrument reads zero. If a higher resistance reading is obtained check all connections. If the reading remains
5、 high, suspect that the test leads may be at fault, or that the 2A non replaceable fuse has ruptured. Continuity Testing 1. Set the selector switch to 2 , or 200, as appropriate. 2. Connect the test leads across the isolated item / circuit under test. 3. Press and hold the Test push button; allow th
6、e needle to settle. There is a separate scale for each range so each reading is direct. Take the reading from the appropriate scale of the instrument. 4. Release the Test push button and disconnect the test leads. Insulation Testing 1. Set the selector switch to 200 M. 2. Connect the R e d test lead
7、 to earth, equipment frame, or cable sheath etc. 3. Connect the Black test lead to the circuit under test or cable core. 4. Confirm that Voltage is not indicated on the instrument. (BM100/4 only) 5. Press and hold the Test push; allow needle to settle, and take the reading from the top scale of the
8、instrument. 6. Release the Test push button. 7. Wait a few moments before disconnecting the test leads, to allow any circuit capacitance to discharge. The BM100/4 will automatically monitor the discharge on its Voltage range, indicating when it is safe to remove the test leads. Resistance Testing (B
9、M101/4 only) 1. Set the selector switch to the 1M resistance range. 2.Connect the test leads across the isolated item / circuit under test. 3. Press and hold the Test push button, allow the needle to settle. Take the reading from the 1M range scale. 4.Release the Test push button and disconnect the
10、test leads. Refer to Safety Warnings before using the instrument RadioFans.CN 收音机爱 好者资料库 SPECIFICATION Range:BM100/4BM101/4 Insulation0,01 - 200 M0,01 - 200 M Resistance-0,01 - 1 M Continuity ()0,01 - 200 0,01 - 200 () 0,01 - 2 0,01 - 2 Insulation Test Voltage:500V d.c.500V d.c. Open Cct. Terminal V
11、oltage: Insulation Range600V d.c.500V at 0,5M)500V at 0,5M) Resistance Range-53V d.c.(nom.) Continuity Ranges ()0,76V d.c.(nom.)0,76V d.c.(nom) ()4,7V d.c.(nom.)4,7V d.c.(nom) Typical Terminal CharacteristicsLimiting value curve Short Cct.Terminal Current: Insulation Range1,6 mA1,6 mA Resistance Ran
12、ge-325 A Continuity Ranges()12,3 mA12,3 mA ()217 mA217 mA Movement:Robust Taut Band type. 250 A F.S.D. A.C. Voltage Measurement (BM100/4 only): The Voltage range is automatically selected when the switch is in any position and the Test push button is not pressed. When connected across the circuit un
13、der test, the BM100/4 will indicate if the circuit is energised (a.c. or d.c.), and measure a.c.voltage up to 600 V. Voltmeter Input Impedance:330 k Automatic Discharge:Capacitive circuits are automatically discharged via an internal (500k) resistor, when the Test push button is released following a
14、n insulation test. Accuracy (at 20C): 2,5% of scale length on all ranges (e.g. 1,9 mm on Insulation range). Insulation range is marked with a white band (Class 1,5 as VDE 0413). Other ranges are Class 3. Humidity:Operation:90% R.H.max. at 20C 80% R.H. max.at 35C Storage95% R.H. max. at 35C Temperatu