Biddle MPM1000_UG 电路图.pdf
《Biddle MPM1000_UG 电路图.pdf》由会员分享,可在线阅读,更多相关《Biddle MPM1000_UG 电路图.pdf(121页珍藏版)》请在收音机爱好者资料库上搜索。
1、Optical Power Meter MEGGER MPM1000 User Guide Guide de lutilisateur Benutzerhandbuch Guida per lutente Gua del Usuario Gebruikersgids Anvndarmanual Brugervejledning Brukerhndbok Kyttohjeet MEGGER RadioFans.CN 收音机爱 好者资料库 2 Contents Introduction4 User Controls and Display5 Operation6 Batteries7 Specif
2、i cation8 Accessories9 Care and Maintenance11 Repair and Warranty12 Symbols used on the Instrument are: Caution: refer to accompanying notes. Equipment complies with relevant EU Directives. RadioFans.CN 收音机爱 好者资料库 SAFETY WARNINGS This instrument is designed for testing fi bre optic installations and
3、 so meets the safety requirements of IEC 60825-1: 1994 (including amendment A11: 1996) and IEC 60825-2: 1995 (including amendment A1: 1998). This products output levels are within the Accessible Emission Limits (AEL) for a Class 1 Laser Product and so does not generate any optical hazards internally
4、. However it can be used to test optical fi bres in environments where light sources that would cause an optical hazard could be present. This corresponds to working within the AEL for Class 1, Class 2, Class 3A and Class 3B lasers, therefore, please take note of the following safety warnings: Under
5、 no circumstances should a connector end-face, prepared optical fi bre or fractured optical fi bre be viewed directly unless the power received from the fi bre is known to be safe (as defi ned by IEC 60825) and under local control. AVOID EXPOSURE TO BEAM if the accessible radiation is within the AEL
6、 for Class 3B lasers. DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS if the accessible radiation is within the AEL for Class 3A lasers. DO NOT STARE INTO BEAM if the accessible radiation is within the AEL for Class 2 lasers. The instrument should not be used if any part of it is da
7、maged. Refer to operating instructions for further explanation and precautions. Safety Warnings and Precautions must be read and understood before the instrument is used. They must be observed during use. NOTE: THE INSTRUMENT MUST ONLY BE USED BY SUITABLY TRAINED AND COMPETENT PERSONS. RadioFans.CN
8、收音机爱 好者资料库 4 Introduction Thank you for purchasing this quality AVO product. Before attempting use of your new instrument please take the time to read this user guide, ultimately this will save you time, advise you of any precautions you need to take and could prevent damage to yourself and the inst
9、rument. The MPM1000 is an accurate optical power meters that can be used for optical loss testing of fi bre optic cables. It has been pre-calibrated for absolute power levels with reference to 1mW (dBm) for 850nm, 1300nm and 1550nm laser wavelengths. The MPM1000 is accurate to 5% -23dBm (0.22dBs) an
10、d has a wide dynamic range of +5dBm to 60dBm with a resolution of 0.1dBm. This instrument provides a more cost-effective testing solution than the more advanced MPM2000 and is geared towards multi-mode operation as it is supplied with the relevant multi-mode patch lead. However it can also be used w
11、ith single-mode fi bre optic cables (hence the1550nm range) and corresponding single-mode patch leads are available in the Accessories. 5 1.0 User Controls and Display 1.1 ON / OFF Switch To turn the unit on, depress the ON/OFF switch. The unit defaults to auto-power-off, dBm and 850nm wavelength me
12、asurement modes. To avoid accidentally discharging the battery when not in use, the meter will auto-power-off after 20 minutes. The ON/OFF switch and auto-power-off are disabled when the meter is selected to the dB REL mode, the meter will then stay on permanently until dB REL is de-selected. To tur
13、n the unit off, depress the ON/OFF switch again. 1.2 Wavelength () Switch The lambda switch is used to select the desired wavelength measurement mode. Depressing the wavelength switch will change between the wavelength measurement modes, selection is indicated by the illumination of the 850, 1300 or
14、 1550 LED. 1.3 dBm / dB REL Switch To select dB REL measurements, depress the dBm/dB REL switch. Selection is indicated by the illumination of the dB REL LED and the display will indicate 00.0 dBm if a stable source is attached. Relative loss measurements may now be performed referenced to the origi
15、nal power level. To change back to dBm measurements, depress the dBm/dB REL switch again. The dB REL LED extinguishing and the dBm LED illuminating indicate selection. Direct dBm measurements may now be taken. If the display indicates the negative bar only, this indicates that the input signal level
16、 is below -62dBm. To prevent accidental turning off of the instrument once a reference power level has been set, the ON/OFF button is disable in dB REL mode (see 1.1). 1.4 Low Battery (LCD) The Lo Batt indicator on the LCD indicates that the 6LR61 (PP3) battery requires replacing or recharging. 6 2.
17、0 Operation This instrument can be used for multiple applications including Optical Loss Testing, Optical Continuity Testing, Acceptance Testing of Fibre Transmitters and Received Power Testing of optical receivers. There are multiple techniques to achieve these types of tests, but a typical procedu
18、re is detailed below: 2.1 Optical Loss Testing Take an optical light source and power meter with appropriate patch cords and mating adapter (uniter) to match the optical fi bre under test. Clean all the connectors and connect the light source via the fi rst patch cord, the uniter and the second patc
19、h cord to the power meter so the attenuation of both cords can be eliminated. The link to be tested is then inserted between them so the optical loss associated only with this link can be found. This test is normally repeated multiple times with the interconnections between the patch cord and the fi
20、 bre under test disconnected and reconnected before each time and an average result taken to ensure repeatability and stability. 2.2 Optical Continuity Testing Use an optical light source (of a known output power) and power meter with patch leads of a known optical loss and a uniter matched to the o
21、ptical fi bre under test. Clean all the connections and insert the link to be tested between the light source and the power meter. Measure the output of the light source through the fi bre under test and check that it is above a pre- determined power level. This is a more simple go, no go test. 2.3
22、Acceptance Testing of Fibre Transmitters Use a power meter with a suitable dynamic range for the transmitter under test and patch leads of a known optical loss. Clean all the connections and connect the power meter to the transmitter via the patch cord. Turn on the transmitter and allow the output t
23、o stabilise before measuring the output and comparing the result to an acceptance standard or versus historical data. This test is normally repeated multiple times with the interconnections disconnected and reconnected before each time and an average result taken to ensure repeatability and stabilit
24、y. 7 2.4 Received Power Testing Use a power meter with a suitable dynamic range for the receiver under test and an adapter to match the connections on the receiver. Clean all the connections and connect the power meter to the fi bre supplying the receiver under test so that the power meter is now wh