1、M 210600 Insulation clean, and with no broken or cracked insulation. ,Replacement fuses must be of the correct size, type and rating. Symbols used on the instrument Caution: risk of electric shock Caution: refer to accompanying notes Equipment protected throughout by Double Insulation (Class II) NOT
2、E THE INSTRUMENT MUST ONLY BE USED BY SUITABLY TRAINED AND COMPETENT PERSONS. RadioFans.CN 收音机爱 好者资料库 OPERATION Live Circuit Warning The live circuit warning indicator will illuminate if 60 V or more is detected at the terminals. Testing should be aborted if lit. Default Voltage measurement The 2106
3、00 will act as a direct reading default voltmeter (0 to 600 V a.c./d.c.) in the Standby mode (when switched On, and any of the Insulation test positions is selected). The Test push must not be pressed when making a voltage test. Note:- The 210600 is internally fuse protected to 500 V. For fuse prote
4、ction with supplies above 500 V, use Fuse Probe Kit FPK5. 1.Turn the instrument On by pressing the On/Off switch-button once. 2.Select any Insulation test position with the rotary selector switch. V is displayed. 3.Carefully connect the test leads to the circuit under test. Do not press the Test pus
5、h. 4.Read the voltage measurement directly from the display. 5.Carefully disconnect the test leads and turn the instrument Off by pressing the On/Off switch-button once. Low Resistance measurement (k) 1.Turn the instrument On by pressing the On /Off switch-button once. 2.Select k with the rotary sel
6、ector switch. 3.Ensure that all test leads are clean and in good condition, and connect them to the isolated circuit under test. 4.Press the Test push and read the measurement directly from the display. 5.Disconnect the test leads and turn the instrument Off by pressing the On/Off switch-button once
7、. Insulation Testing (M) Automatic circuit discharge is effective when the Test push is released, and decaying voltage is displayed until the circuit is discharged. 1.Turn the instrument On by pressing the On/Off switch-button once. 2.Ensure that all test leads are clean and in good condition, and c
8、onnect them to the isolated circuit under test. 3.Select the required test voltage with the rotary selector switch. 4.Press the Test push and read the measurement directly from the display. Overrange is indicated by . 5.Release the Test push and monitor any displayed voltage to confirm when any disc
9、harging voltage decays to zero. 6.When the circuit has discharged, disconnect the test leads and turn the instrument Off by pressing the On/Off switch-button once. Low Battery Refer to Safety Warnings before using the instrument DISPLAY FEATURES Live Circuit Warning RadioFans.CN 收音机爱 好者资料库 Using the
10、 Guard Terminal For basic insulation tests and where there is little possibility of surface leakage affecting the measurement, it is unnecessary to use the guard terminal. In cable testing, there may be surface leakage paths across the insulation between the bare cable and the external sheathing due
11、 to the presence of moisture or dirt. Where it is required to remove the effect of this leakage, particularly at high testing voltages, a bare wire may be bound tightly around the insulation and connected via the third test lead to the guard terminal G. The guard terminal is at the same potential as
12、 the negative terminal. Since the leakage resistance is effectively in parallel with the resistance to be measured, the use of the guard causes the current flowing through surface leakage to be diverted from the measuring circuit. The instrument therefore reads the leakage of the insulator, ignoring
13、 leakage across its surface. SPECIFICATION Insulation Ranges Measuring Ranges:0 - 1.999M at all test voltages 19.99 M at all test voltages 199.9 M at all test voltages 1999 M at 500 V and 1000 V d.c. test voltages Fully auto - ranging at all voltages Test Voltages (d.c.):100 V; 250 V; 500 V; 1kV Tes
14、t V. Accuracy:5% at open circuit Short Cct. Current:1.2 mA nominal Accuracy (73.4F 3.6F): 500 M: 3% 2 digits 500 M to 1999 M: 5% 2 digits Temp. Co-efficient:86F 0.14% per F 500 M to 1999 M: 86F 0.11% per F, 86F, 0.28% per F, Hum Rejection:Within twice the normal accuracy if the noise current does no
15、t exceed 1 mA for the 1 kV range, or 0.5 mA for the other ranges and is within 45 Hz to 65 Hz. Low resistance Range Measuring Range:0 - 1.999 k 19.99 k Open Cct. Voltage:4.3 V nominal Accuracy (73.4F 3.6F): 2% of reading 1digit 1100 1000 900 800 700 600 500 400 300 200 100 0 0.010.111010010001000010
16、0000 Terminal Characteristics Leakage path to +ve terminal to G terminal to -ve terminal Tightly bound bare wire RadioFans.CN 收音机爱 好者资料库 M Archcliffe Road Dover Kent CT17 9ENTel: +44 (0) 1304 502100 EnglandFax: +44 (0) 1304 207342 PO Box 9007 Valley Forge PA 19484-9007Tel: +1 (610) 676-8500 U.S.A.Fa